YV180X_Ope_E.pdf - 第269页

6 -34 EPD8013110 Operation Chapter 6 6 Using various functions 6 2. Register the third and fourth marks in the second data line as follows. Mark : Enter the mark No. registered as the third mark in the Mark Information. …

100%1 / 307
6
-33
EPD8013110
Operation
Chapter 6
6
Using various functions
2 Open the Local Fidu. Info. screen and specify the fiducial
information.
Press the [F3] key in the <2/1/EDIT_DATA> mode to display the edit item
menu box. Select Local Fidu. Info. from the menu box and press the
[ENTER] key. Specify the fiducial information as outlined below. (In this
setting example, register the first and second marks in the first data line
and the third and fourth marks in the second data line.)
Local Fidu. Info. screen
27620-C0-00
PCB :
Mark
15
16
X1 Y1 Mrk2
15
17
Skip
Exec
Exec
Comment
X2 Y2 Type
4Local-M
4Local-S
OBJ :Local Fidu.Info.
No.
1
2
3
4
<<<APPLICATION>>> 2/DATA/M
<<MODE>> 1/EDIT_DATA
1. Register the first and second marks in the first data line as follows.
Mark : Enter the mark No. registered as the first mark
in the Mark Information.
X1, Y1 : Enter the coordinates of the first mark relative
to the PCB origin (or the block repeat No.1
point in the case of block repeat reference) in
millimeters.
Mrk2 (Mark 2) : Enter the mark No. registered as the second
mark in the Mark Information. When the
second mark is identical with the first mark,
enter 0 here.)
X2, Y2 : Enter the coordinates of the second mark
relative to the PCB origin (or the block repeat
No.1 point in the case of block repeat
reference) in millimeters.
Type : Set to 4Local-M.
Skip : Set to Exec (initial setting).
Comment : You can enter a comment here as necessary.
6
-34
EPD8013110
Operation
Chapter 6
6
Using various functions
6
2. Register the third and fourth marks in the second data line as follows.
Mark : Enter the mark No. registered as the third mark
in the Mark Information.
X1, Y1 : Enter the coordinates of the third mark relative
to the PCB origin (or the block repeat No.1
point in the case of block repeat reference) in
millimeters.
Mrk2 (Mark 2) : Enter the mark No. registered as the fourth
mark in the Mark Information. If the fourth
mark is identical with the third mark, enter 0
here.)
X2, Y2 : Enter the coordinates of the fourth mark
relative to the PCB origin (or the block repeat
No.1 point in the case of block repeat
reference) in millimeters.
Type : Set to 4Local-M.
Skip : Set to Exec (initial setting).
Comment : You can enter a comment here as necessary.
3. When all the settings are complete, press the [ESC] key twice to exit the
Local. Fidu. Info. screen, then select <2/1/D8 SAVE PCB DATA> and
press the [ENTER] key.
3 Open the Mount Info. screen and set the fiducial function.
1. Press the [F3] key to display the edit item menu box and select Mount
Info.. On the Mount Info. screen, move the cursor to the data line for
which you want to set the 4-point fiducial function.
2. Enter the mark data No. you have registered in the Local Fidu. Info., in
the FidMk column of the selected data line. If enter the mark No. for
4Local-S here, this will be a data error.
3. To correct the position on one mount data, specify one piece of fiducial
mark data for one piece of mount data. To correct the positions on
multiple pieces of mount data, specify one piece of fiducial mark data
for multiple pieces of mount data.
Setting the 4-point fiducial function on the Mount Info. screen
27621-C0-00
PCB :
Sign OfLandPattern Comp X Y R Head FidMk
1
1
1
1
BadMk Skip?
OBJ :Mount Info.
No.
1
2
3
4
<<<APPLICATION>>> 2/DATA/M
<<MODE>> 1/EDIT_DATA
Enter data No. specified as 4Local-M on Local Fidu. Info. screen.
6
-35
EPD8013110
Operation
Chapter 6
6
Using various functions
4 Open the PCB Info. screen and set the local fiducial func-
tion.
Press the [F3] key to display the edit item menu box again and select PCB
Info.. Set the Local Fiduc. parameter in the PCB Info. to Use.
Setting the local fiducial function on the PCB Info. screen
27622-C0-00
PCB :
LocalBadmark Use
OBJ : PCB Info.
<<<APPLICATION>>> 2/DATA/M
<<MODE>> 1/EDIT_DATA
Set to Use.
5 Save the data.
Press the [ESC] key to exit the current edit screen, then select <2/1/D8
SAVE PCB DATA> and press the [ENTER] key.