Creating the PCB data
q Specify Unloader Count/Max.
In the Y/Y1 column of this parameter, specify the number of PCBs that can
be stored in one rack of the unloader. When the specified number of PCBs
has been produced and transferred out into the unloader, the machine
stops transfer of the production PCB until the unloader replaces the rack.
Unloader Count
The number of PCBs transferred into the unloader is displayed in this
column. Set this to 0 as a start.
Max
Specify the maximum number of PCBs that can be stored in one rack
of the unloader. If this is set to 0, the machine continues production
without checking the number of PCBs transferred out into the
unloader. Enter 0 under the following conditions.
The unloader being used provides a rack switching signal output.
This setting data is to be used for the machine just before
reflowing.
w Set operating conditions.
Using the [Space], [INS] or [DEL] key, specify the necessary operating
conditions displayed on the lower half of the screen,
Mount
Set to Exec to perform component mounting.
VacCheck
Set this parameter to Use. Setting to Use allows the machine to
check whether components are being picked up during operation
based on the vacuum level, as well as checking with the vision
system.
Alignment
Set to UseAlign. This setting allows the machine to check compo-
nent recognition during pickup.
PcbFixDevice
Select the proper PCB clamping method according to the PCB to be
produced.
Locate Pin : A PCB is clamped on the conveyor only with the
locate pins.
Pin+PushUP : A PCB is clamped on the conveyor with the
locate pins and push-up pins. This is the most
accurate and preferred method.
Edge Clamp (option) : A PCB is clamped on the conveyor with
the edge clamps, push-in unit and push-up
pins, without using the locate pins.
Pre-Fix Timer
The machine begins to clamp the PCB immediately after it passes
above the PCB sensor installed just before the main stopper. The
optimum clamping timing (delay time with respect to the sensor
detection) depends on the PCB size and conveyor speed.. Use this
parameter to set the clamp timing (0.0 to 1.9 sec.).
5
-94
EPD8013110
Operation
Chapter 5
5
Creating the PCB data
Trans-Height
After components are mounted, the machine permits the conveyor to
carry out the PCB when the push-up unit is lowered. If components
have already been mounted on the reverse side of the PCB, the push-
up unit must be lowered sufficiently to avoid interference from push-
up pins with those components. This parameter specifies the height of
the push-up unit at which the conveyor is allowed to carry out each
type of PCB. Enter the distance in millimeters from the point where
the push-up unit is raised to clamp the PCB. This distance can be 3 to
30mm.
Conv. Timer
Set to 0.0 sec. for normal shape PCBs. If specially configured PCBs
(for example, PCBs with cutout parts or through-holes) are used and
the exit sensor cannot detect them reliably, try setting this timer in the
range of 0.0 to 9.9 sec. The conveyor motor continues turning for the
specified time even after the PCB sensor turns off.
Precede Pick
When this is set to Use, the head assembly starts moving to pick up
and recognize components as soon as the preceding PCB has been
carried out and the next PCB is carried in. This will shorten the cycle
time.
Conv. Y Speed
This parameter specifies the conveyor Y-axis (YT-axis) moving speed.
Set to FAST in most cases. If the mounted components move or
slide on the PCB due to the YT-axis movement, set this parameter to a
slower speed.
Local Fiduc.
Set to Use when using the local fiducial correcting function, and
NotUse when not using this function. This parameter is available
only when the data is input in Fidu. Info. in the main window
menu. Refer to 5. Using the fiducial functions in Chapter 6 for more
details.
Local Badmark
Set to Use when using the local badmark function, and NotUse
when not using this function. This parameter is available only when
the data is input in Local BadMrkInfo. in the main window menu.
Refer to 6. Using the badmark functions in Chapter 6 for more
details.
Retry Seq.
The retry sequence can be selected from the following methods.
Group : Retry is repeated with the head which caused an error,
until component mounting specified as one group is
complete.
Block : Retry is performed with the head which caused an error
after component mounting in one block is complete.
Auto : Retry is performed with any free head after component
mounting in one block is complete.
Sp. Function
This parameter is not displayed on standard machines. If the machine
has a special function, set to Use when using it, or NotUse when
not using.
5
-95
EPD8013110
Operation
Chapter 5
5
Creating the PCB data
e Save the data.
When settings are complete, press the [ESC] key twice to exit the current
edit screen, then select <2/1/D8 SAVE PCB DATA> and press the [ENTER]
key.