YV180X_Ope_E.pdf - 第230页

5 -154 EPD8013110 Operation Chapter 5 5 Creating the PCB data Comp : Select the Comp column setting in the mount information with the number keys. X : Select the X column setting in the mount information with the number …

100%1 / 307
5
-153
EPD8013110
Operation
Chapter 5
5
Creating the PCB data
13.2 Data replace
The setting data in mount information and component information can be
replaced at one time.
13.2.1 Data replace in mount information
1 Open the Mount Info. screen.
2 Run <2/1/C1 EDITOR_ASSISTANT> - REPLACE com-
mand.
1. Press the [ESC] key , select <2/1/C1 EDITOR ASSISTANT> and press the
[ENTER] key.
The EDITOR ASSISTANT submenu box appears.
2. Select REPLACE and press the [ENTER] key.
A box for data replace appears.
REPLACE command
27571-C0-00
<COMMAND_LIST>
R1608
R2125
R3216
1
2
3
C/EDIT_TOOL
C1 EDITOR ASSISTANT
EDITOR ASSISTANT
REPLACE
3
3
3
3
0
0
0
0
Exec
Exec
Exec
Exec
3 Set Select condition item.
1. Use the up/down arrow keys to select the parameter item (shown in
red) and then the setting you want to replace in the blue column just
under the parameter item.
Setting for “Select condition item” (Mount Info.)
27572-C0-00
Select condition item
Comp
3
Select change item
Skip?
Skip
Use number keys, [INS] or
[DEL] key to make setting
Use arrow keys to
make selection
5
-154
EPD8013110
Operation
Chapter 5
5
Creating the PCB data
Comp : Select the Comp column setting in the mount
information with the number keys.
X : Select the X column setting in the mount
information with the number keys.
Y : Select the Y column setting in the mount
information with the number keys.
R : Select the R column setting in the mount
information with the number keys.
Head : Select the Head column setting in the mount
information with the number keys.
Fid Mk : Select the FidMk column setting in the mount
information with the number keys.
Bad Mk : Select the BadMk column setting in the mount
information with the number keys.
Skip? : Select the Skip? column setting in the mount
information with the [INS], [DEL] or [Space]
key.
LandPattren : Select the SignOflandPattern column setting in
the mount information with the [INS], [DEL]
or [Space] key.
ALL : Specify ALL if you want to replace all the
data registered in the mount informa-
tion.
2. When all the necessary settings are complete, press the [ENTER] key to
advance to the next step.
4 Set Select change item.
Select the parameter item you want to change and specify the new setting
that supersedes the current setting.
Setting for Select change item (Mount Info.)
27573-C0-00
Select condition item
Comp
3
Select change item
Skip?
Skip
Use number keys, [INS] or
[DEL] key to make setting
Use arrow keys to
make selection
1. Use the up/down arrow keys to select the parameter (shown in red) you
want to change. Then, enter or select the new setting for the selected
parameter with the number keys, or [INS], [DEL] or [Space] key.
Comp : Specify the Comp column setting in the mount
information with the number keys.
X : Specify the X column setting in the mount
information with the number keys.
5
-155
EPD8013110
Operation
Chapter 5
5
Creating the PCB data
Y : Specify the Y column setting in the mount
information with the number keys.
R : Specify the R column setting in the mount
information with the number keys.
Head : Specify the Head column setting in the mount
information with the number keys.
Fid Mk : Specify the FidMk column setting in the mount
information with the number keys.
Bad Mk : Specify the BadMk column setting in the
mount
information with the number keys.
Skip? : Specify the Skip? column setting in the mount
information with the [INS], [DEL] or [Space]
key, to determine whether to perform
component mount.
X offset / Y offset : Enter the desired offset to add to or subtract
from the current XY data in the mount
information. For
example, if you want to shift the mounting
position selected in Step 3 by - 1mm in the X
or Y direction, enter -1.00 here with the
number keys.
R offset : Enter the desired offset to add to or subtract
from the current R data in the mount informa-
tion. For example, if you want to change
the angle selected in Step 3 by 90 degrees,
enter 90.00 here with the number keys.
X / Y Sign Reverse : If you want to reverse the plus / minus signs
for the current X data in the mount informa-
tion, select Use with the [INS], [DEL] or
[Space] key. If not, select None. For
example, when set to Use, a setting of
14.00 and vice versa.
2. When all the necessary settings are complete, press the [ENTER] key to
perform replace.