YV180X_Ope_E.pdf - 第265页

6 -30 EPD8013110 Operation Chapter 6 6 Using various functions 6 Point fiducial settings 23609-C0-00 1st mark (X1, Y1) Mounting center 2nd mark (X2, Y2) Local Fiducial settings 23610-C0-00 2nd mark (X2, Y2) 1st mark (X1,…

100%1 / 307
6
-29
EPD8013110
Operation
Chapter 6
6
Using various functions
5.2.1 Point fiducial and local fiducial functions
c
CAUTION
The following procedure for setting the fiducial function is explained, assuming that
you already have the complete PCB data needed for component mount. If you are not
yet finished with creating the PCB data, complete the PCB data first while referring to
Chapter 5 in this manual and then set the fiducial function.
1 Create the mark information.
On the Mark Info. screen you must first create the local fiducial mark data
to be used. When the two fiducial marks are identical, register the data for
just one mark. If they are different from each other, register the data
according to each mark. (Refer to 4. Creating the mark information in
Chapter 5.)
2 Open the Local Fidu. Info. screen and set the fiducial
information.
Press the [F3] key in the <2/1/EDIT_DATA> mode to display the edit item
menu box. Select Local Fidu. Info. from the menu box and press the
[ENTER] key. On the Local Fidu. Info. screen, specify the fiducial informa-
tion as follows.
Mark : Enter the mark No. registered as the first mark
in the mark information.
X1, Y1 : For the point fiducial mark, enter the coordi-
nates of the first mark relative to the center of
the mounting position in millimeters. For the
local fiducial mark, enter the coordinates of
the first mark relative to the PCB origin (or the
block repeat No.1 point in the case of block
repeat reference) in millimeters.
Mrk2 : Enter the mark No. registered as the second
mark in the mark information. When the
second mark is identical with the first mark,
enter 0 here.)
X2, Y2 : For the point fiducial mark, enter the coordi-
nates of the second mark relative to the center
of the mounting position in millimeters. For
the local fiducial mark, enter the coordinates
of the second mark relative to the PCB origin
(or the block repeat No.1 point in the case of
block repeat reference) in millimeters.
Type : Set to Point for the point fiducial mark. Set
to Local for the local fiducial mark.
Skip : Set to Exec (initial setting) for both the point
and local fiducial marks.
Comment : You can enter a comment here as necessary.
This does not affect the data setting.
6
-30
EPD8013110
Operation
Chapter 6
6
Using various functions
6
Point fiducial settings
23609-C0-00
1st mark (X1, Y1)
Mounting center
2nd mark (X2, Y2)
Local Fiducial settings
23610-C0-00
2nd mark (X2, Y2)
1st mark (X1, Y1)
PCB origin or
block repeat
3 Open the Mount Info. screen and set the fiducial function.
1. Press the [F3] key to display the edit item menu box and select Mount
Info.. When the Mount Info. screen is open, move the cursor to the
data line for which you want to set the local fiducial function.
2. Enter the mark data No. you have registered in the Local Fidu. Info., in
the FidMk column of the selected data line.
3. When using the point fiducial function, specify one piece of fiducial
mark data for one piece of mount data. When using the local fiducial
function, specify one piece of fiducial mark data for multiple pieces of
mount data.
6
-31
EPD8013110
Operation
Chapter 6
6
Using various functions
Specifying the local fiducial mark on the Mount Info. screen
27617-C0-00
<<<APPLICATION>>> 2/DATA/M
<<MODE>> 1/EDIT_DATA
PCB :
SignOfLandPattern Comp X Y R Head FidMk
1
2
3
4
4
5
5
MadMk Skip?
OBJ :Mount Info.
No.
1
2
3
4
5
6
7
Point fiducial : Specify one piece of fiducial mark
data for one piece of mount data.
Local fiducial : Specify one piece of fiducial mark data
for tow or more pieces of mount data.
4 Open the PCB Info. screen and set the local fiducial func-
tion.
Press the [F3] key to display the edit item menu box again, then select
PCB Info. and set the Local Fiduc. parameter to Use.
Setting the local fiducial function on the PCB Info. screen
27618-C0-00
PCB :
Local Fiduc. Use
OBJ : PCB Info.
<<<APPLICATION>>> 2/DATA/M
<<MODE>> 1/EDIT_DATA
Set to “Use”.
5 Save the data.
Press the [ESC] key to exit the current edit screen, then select <2/1/D8
SAVE PCB DATA> and press the [ENTER] key.
This completes the local fiducial function settings.
n
NOTE
If the distance between the two fiducial marks is too close, detection and calculation
errors tend to occur.
A total of up to 512 pairs of local fiducial marks can be set for the PCB data.