YV180X_Ope_E.pdf - 第125页
5 -49 EPD8008100 Operation Chapter 5 5 Creating the PCB data 6. SHAPE INFO. parameters When “ Alignment T ype ” is set to “ Simple BGA ” , the following parameters are displayed in the SHAPE INFO. sub-windo w . 61. Body …

5
-48
EPD8008100
Operation
Chapter 5
5
Creating the PCB data
27. Pick Vacuum, Mount Vacuum
These are reference vacuum pressures used for checking the pickup and
mount vacuum levels. Use the default settings and adjust them as needed
in the Adjust Assistant mode. (See “3.7” in this chapter.)
28. Conv. Y Speed
Refer to the description in “3.3.1 Standard chip components”.
4. DUMP INFO. parameters
31. Dump Way
Set to “Station” when a dump station (option) is used and to “Dump POS.”
when not used. Refer to the Discard point parameter explained in the
mounter service manual.
32. Retry Times
Refer to the description in “3.3.1 Standard chip components”.
5. VISION INFO. parameters
41. Alignment Group
Set to “Ball”.
42. Alignment Type
Set to “BGA”.
43. AlignmentModule
This parameter specifies the lighting method for recognizing a component.
Use the default setting (Fore).
For descriptions of the following VISION INFO. parameters, refer to
“3.3.1 Standard chip components”.
44. Light Selection
Set this parameter to “Main + Coax” to edit the arrangement of the BGA
leads. If you want to check nicks on the BGA leads, set to “Only Side“.
45. Lighting Level
46. Comp. Threshold
This parameter is skipped for BGA components.
47. Comp. Tolerance
48. Search Area
49. Datum Angle
50. Comp. Intensity
51. MultiCam. Marker

5
-49
EPD8008100
Operation
Chapter 5
5
Creating the PCB data
6. SHAPE INFO. parameters
When “Alignment Type” is set to “Simple BGA”, the following parameters
are displayed in the SHAPE INFO. sub-window.
61. Body Size X, Body Size Y
Enter the correct dimensions measured with a vernier caliper or microme-
ter.
62. Body Size Z
Enter the correct diameter measured with a vernier caliper or micrometer.
63. Dot number N, Dot number E
Enter the number of ball terminals arrayed in the N and E directions. If the
number of terminals per array differs from each other, enter the largest
number of terminals per array.
64. BGA diameter
Enter the diameter of ball terminals.
65. BGA pitch N
Enter the spacing between ball terminals displayed in the N (north)
position of the vision monitor.
66. BGA pitch E
Enter the spacing between ball terminals displayed in the E (east) position
of the vision monitor.
67. Dot amount
Enter the total number of ball terminals of the BGA component.
68. Binary Level
The Comp Threshold parameter is invalid when the Alignment Type
parameter is set to “BGA” or Simple BGA”. Instead, the binary level can
be adjusted with this parameter. For example, if the white portion in the
image appears larger than the actual area, enter a plus value. (For more
details, see “Adjusting the Binary Level” explained later in this section.)
SHAPE INFO. parameters for BGA component
23516-C0-00
N
S
E
W
B
A
C
D
E
F
G
C
A : Body Size X
B : Body Size Y
C : Body Size Z
D : Dot number N
E : Dot number E
F : BGA pitch
G : BGA diamete
r
Side view
Bottom view

5
-50
EPD8008100
Operation
Chapter 5
5
Creating the PCB data
●Editing the BGA ball lead information
After you have created BGA component information, you can further
edit the ball lead information to improve recognition accuracy by using
the Adjust Assistant commands (see “3.7” in this chapter for details on
the Adjust Assistant commands). This is particularly effective in recog-
nizing micro BGA components such as CSP.
1 Open the Adjust Assistant screen of the ball lead compo-
nent.
Line up the cursor with the target component and press the [F6] key to
open the Adjust Assistant screen.
Adjust Assistant screen
27517-C0-00
Comp. Name : BGA_2020
Adjust Assist Items
Feeder set No.
Comp. Tolerance
Comp. Threshold
Lighting Level
Search Area
Monitor Mode
Condition Chk.Mode
25
30
30
8.00
Nothing
ROW
(%)
(mm)
6 / 8
Command
PICK UP COMP.
*
VISION TEST
PARM. SEARCH
DISCARD COMP.
DRAW THE SHAPE
CHK GRAY VALUE
EXIT
2 Set the Feeder Set No. and Monitor Mode parameters.
Press the right arrow key to move the cursor into the Adjust Assistant Items
window, and set the Feeder Set No. and Monitor Mode parameters as
follows.
Feeder Set No. : Set to a feeder position where you can easily attach
the component by hand.
Monitor Mode : Nothing
3 Execute the PICK UP COMP. command.
Press the left arrow key to move the cursor back to the command list
screen (left-hand screen), then execute the PICK UP COMP. command.
e
The head assembly moves to the feeder position specified in the Feeder Set
No. After the head assembly stops, press the emergency stop button and
then attach the component to the nozzle tip by hand.
4 Execute the VISION TEST command.
Cancel emergency stop, then execute the VISION TEST command.
The image currently displayed on the vision monitor is reset.
5 Execute the DRAW THE SHAPE command.
Follow the utility messages displayed on the operation monitor to open the
screen for editing the BGA ball lead information, which will appear on the
upper left of the vision monitor.