Q170226E01.pdf - 第280页
7.3 Digital Operator SERVICE MANUAL RH5 7.3−3 DA3SEC−84−310−A0 7.3.2 Inputting Bit No. (Cn−01 and Cn−02) Display Procedure Remarks 1 Set the digital operator to the desired driver . x Set the digital operator changes the…

RH5
7.3 Digital Operator
SERVICE MANUAL
7.3−2
DA3SEC−84−310−A0
Display Procedure Remarks
7 Press MODE/SET key to change the display to Cn−03
and then press DOWN key three times to change to
00−00.
8 Press DATA key to change the display to Cn−00 and
then press MODE/SET to change to “run”.
9 Remove the digital operator from the driver and turn
OFF the power to the machine once.
10
[NC axis JOG check]
NC axis Present position
XY table X=+0.00 mm
Y=+0.00 mm
Z axis (casette) 0.00 mm
Loader width
adjustment *****
Unloader width
adjustment *****
Table width
adjustment *****
Turn the power back ON and press “F1” (NC JOG
CHECK) to make sure the each axis are set to r0.00
mm.
x The values other than
r0.00 mm shall be
adjusted to, set to r0.00
mm using UP and
DOWN keys.

7.3 Digital Operator
SERVICE MANUAL
RH5
7.3−3
DA3SEC−84−310−A0
7.3.2 Inputting Bit No. (Cn−01 and Cn−02)
Display Procedure Remarks
1 Set the digital operator to the desired driver. x Set the digital
operator changes the
display to “run”.
2 Press ORG. switch in manual, 1BLOCK mode then
press servo lock switch.
x The display changes
to “b, b”.
3 Press MODE/SET to change the display to Cn−00 and
then press DATA key to specify the channel to be
input.
x Select channel
Cn−01 or Cn−02.
4 Press DATA key. x The display changes
to “ ‘ 0”.
5
Bit No.
Bit No.
to be
set
Using UP and DOWN keys, set the bit No. of the
memory switch to be set to the right end of the panel.
6
Lights up when ON
goes out when OFF
Press MODE/SET key to turn ON/OFF the memory
switch.
x The memory switch
lights up when ON and
goes out when OFF.

RH5
7.3 Digital Operator
SERVICE MANUAL
7.3−4
DA3SEC−84−310−A0
Display Procedure Remarks
7 Repeat steps 5 and 6 as necessary.
8 Press DATA key to store data and then press DOWN
key to change the setting value at the right end of the
panel to “0”.
x Pressing DATA key
flashes the data.
9 Press DATA key to display Cn−01 or Cn−02 and then
press DOWN key to change to Cn−00.
10 Press MODE/SET key several times to change the
display to “b, b” and then press servo lock switch.
x Pressing servo lock
switch changes the
display to “run”.
11 Turn OFF the power to the machine and remove the
digital operator. Then turn the power back ON.
x After turning the power
OFF and then ON, the
setting value having
been changed will be
available.