Q170226E01.pdf - 第347页
RH5 8.4 AC Servomotor Drivers SERVICE MANUAL 8.4−10 DA3SEC−85−480−A0 Error Display Confirmation with Digital Operator Error Display with Digital Operator and T raceback Data Digital Operator (T raceback Data) Detection P…

8.4 AC Servomotor Drivers
SERVICE MANUAL
RH5
8.4−9
DA3SEC−85−480−A0
Status Indication Mode
When this mode is selected using the digital operator, the condition of the SERVOPACK is indicated
with bits and codes as shown below.
Panel Display
Bit data
BB
Control ON
TGON
IN−A input (At speed control mode)
Reference pulse input (At position control mode)
Power ready
Code
IN−B input (Only at
speed control mode)
Bit Data Contents
Bit Data Contents
Control ON Lights up when control power is turned ON.
BB Lights up with base block and goes out when servo is turned ON.
TGON Lights up when the motor rotating speed exceeds TGON level
(standard setting: 20 r/min).
IN−A input
Reference pulse input
Lights up if IN−A higher than TGON level was input. (At speed
control mode)
Lights up during inputting reference pulse (At position control mode)
IN−B input Lights up if IN−B higher than TGON level was input. (At position
control mode)
Power ready Lights up when power to the main control circuit is supplied.
Codes and Status
Code Status
Base block
Running
Forward turn inhibited
Reverse turn inhibited
Alarm status
See
“
Error
Display
See
Error
Display
Confirmation with Digital
Operator
”
(page
53
−
10 )
:
Operator
(page
5
.
3
−
10
.
)
.

RH5
8.4 AC Servomotor Drivers
SERVICE MANUAL
8.4−10
DA3SEC−85−480−A0
Error Display Confirmation with Digital Operator
Error Display with Digital Operator and Traceback Data
Digital Operator
(Traceback Data)
Detection
Parameter breakdown
Parameter setting error
Overcurrent (or heatsink overheat)
MCCB thermal trip
Regenerative error
Overflow
Overvoltage
Excessive feedback speed
Undervoltage
Overload (Too high)
Overload (Too low)
Reference input read error
Overrun (Motor or encoder miswiring)
PA−, PB−phase disconnection of PG signal line
PC−phase disconnection of PG signal line
Input power supply phase error
Power supply startup error
Not applicable to alarm
CPU fault
is displayed.
(SERVOPACK 7−segment LED)

8.4 AC Servomotor Drivers
SERVICE MANUAL
RH5
8.4−11
DA3SEC−85−480−A0
Digital Operator and 7−segment LED Indication for Troubleshooting
Digital Operator and 7−segment LED Indication for Troubleshooting
7−seg ment
LED
indication
Digital Operator
Indication
(T raceback
Monitor)
Lighting Condition Probable Causes Countermeasures
O
v
e
r
cu
rr
e
n
t
Lights up when power
to the control circuit is
supplied.
Defective control
circuit board (1PWB)
Replace the
SERVOPACK.
Overcurrent
Lights up when power
to the main circuit is
supplied and servo
power is turned ON.
No fuse blown.
x Defective current
feedback circuit
x Defective main
circuit transistor
module
Replace the
SERVOPACK.
Lights up during
operation.
Lights up even after
turning power OFF
and then turning back
Stopped fan Check the fan rotation.
(DR20, 30, 40)
and
then
turning
back
ON.
Operation can be
resumed after a
certain period of time
by pressing <RESET>
key.
Ambient temperature
near the SERVOPACK
is over 50 qC.
Adjust the ambient
temperature of the
SERVOPACK for 50qC
or lower. (Heatsink
overheat)
MMCB
trip
Lights up when power
to the control circuit is
supplied.
Defective control
circuit board (1PWB)
(MCCB must be ON.)
Replace the
SERVOPACK.
MMCB
t
r
i
p
Lights up when power
to the main circuit is
supplied.
Defective main circuit
thyristor/ diode hybrid
module.
Replace the
SERVOPACK. (Do not
turn the power ON
again.)
MCCB is ON. Replace the
SERVOPACK.
MCCB is OFF. Turn ON the MCCB.
Regenerative
error
Lights up when power
to the control circuit is
supplied.
Defective control
circuit board (1PWB)
Replace the
SERVOPACK.
Regenerative
error
Lights up in 0.5 to 1
second after power to
th
i
iit
i
Defective regenerative
transistor
Replace the
SERVOPACK.
p
the main circuit is
turned ON.
x Defective
regenerative resistor
x Regenerative
resistor has not
been connected.
Check or replace the
regenerative resistor.
(Replace the
SERVOPACK.)