3.2 Connecting the Power Supply
SERVICE MANUAL
3.2−2
DA3SEC−11−020−A0
3.2.2 Connecting Procedures
Follow the procedures below to connect the cables.
1. Turn OFF the switch of the distribution panel.
2. Connect the distribution panel to the input terminals of the main switch by 3−core cable and one core
protective earth cable.
Must be connected the protective earth (PE).
Distribution panel Main switch
L1
L2
L3
N
PE
PE PE
L1
L2
L3
T1
T2
T3
Cable gland
L1
L3
PE
10 15 mm
L2
PE Cable
=CHECK=
Instruction must be according to national requirement.
SERVICE MANUAL
RH5
4.0−1
4ダミー(Sectionのレベル1)
4.0ダミー(Sectionのレベル2)
RH5
SERVICE MANUAL
4.0−2
DA3SEC−80−000−A0
DA3SEC−80−000−A0
Sentence No.
4. INSPECTION
This chapter includes the routine maintenance.
x Please make use of routine maintenance and give instructions to customers.
x Be sure to read “Safety Precautions” in chapter 1 carefully.