Q170226E01.pdf - 第291页
RH5 8.2 List of Software Settings SERVICE MANUAL 8.2−2 DA3SEC−85−470−B0 Real ROM address Description Default 0FFF9E (06801E) 7FF9E High−speed insertion tact 0: Normal 1: High−speed 1 (0.36 sec) 2: High−speed 2 (0.29 sec)…

8.2 List of Software Settings
SERVICE MANUAL
RH5
8.2−1
DA3SEC−85−470−B0
8.2 List of Software Settings
DA3SEC−85−470−B0
Sentence No.
Real ROM
address
Description Default
0FFF80
(068000)
7FF80 Machine model SW (1)
0: RHP, RHPII, RHIII, RH5
2: RHUP
4: RHXP (7.5/10)
5: RHXP (5/7.5/10)
0
0FFF82
(068002)
7FF82 Machine model SW (2)
0: Standard single PCB flow model (M)
1: Standard double/large single PCB flow model (L)
2: Large double PCB flow model (LL)
0
0FFF84
(068004)
7FF84 No. of max. cassettes (For two separate feeder carriage, total of ZL and
ZR cassettes.)
RHXP: 2C (44) RHP: 3C (60) RHP, RHPII: 50 (80)
RHUP: 38 (56) RHII: 3E (62) RH5: 28 (3E/50)
0FFF86
(068006)
7FF86 No. of loading available cassettes on ZL−axis (Not used for one feeder
type)
RHXP: 16 (22) RHP: 1E (30) RHII: 00 (0)
RHUP: 1C (28) RHP, RHPII: 28 (40)RH5: 00
00
0FFF88
(068008)
7FF88 No. of loading available cassettes on ZR−axis (Not used for one feeder
type)
RHXP: 16 (22) RHP: 1E (30) RHII: 00 (0)
RHUP: 1C (28) RHP, RHPII: 28 (40)RH5: 00
00
0FFF8A
(06800A)
7FF8A Z axis 2−separate feeder carriage option SW
0: One feeder type
1: Two separate feeder carriage
0
0FFF8C
(06800C)
7FF8C Display text setting
0: Japanese
1: English
J−0
E−1
0FFF90
(068010)
7FF90 Printer connection option SW
0: Not connected
1: Connected
1
0FFF92
(068012)
7FF92 FDD connection option SW
0: Not connected
1: Connected
1
0FFF96
(068016)
7FF96 Host remote command (C) option SW
0: Not connected
1: Connected
1
0FFF98
(068018)
7FF98 Host real−time command (R) option SW
0: Not connected
1: Connected
1
0FFF9A
(06801A)
7FF9A Automatic width adjustment (APC) board connection option SW
0: Not connected
1: Connected
3: New automatic width adjustment (RHPII, RHII, RH5)
0
0FFF9C
(06801C)
7FF9C Rear component exhaust display LED unit connection option SW (Only
available for two separate feeder carriage system)
0: Not connected
1: Connected
0

RH5
8.2 List of Software Settings
SERVICE MANUAL
8.2−2
DA3SEC−85−470−B0
Real
ROM
address
Description Default
0FFF9E
(06801E)
7FF9E High−speed insertion tact
0: Normal
1: High−speed 1 (0.36 sec)
2: High−speed 2 (0.29 sec)
2
0FFFA0
(068020)
7FFA0 Self−correction (RCG) board connection option SW *1
0: Not connected
1: Connected
1
0FFFA2
(068022)
7FFA2 Pulse motor (PMC) board connection option SW *1
0: Not connected
1: Connected
0
0FFFA4
(068024)
7FFA4 Number of cameras *1 1
0FFFA5
(068025)
7FFA5 Camera installation position
0: camera not connected or pulse motor used
1: Fixed camera on insertion position side
2: Fixed camera on recognition position side
1
0FFFA6
(068026)
7FFA6 Bad mark sensor connection option SW
0: Not connected
1: Connected
0
0FFFA8
(068028)
7FFA8 Board edge positioning unit connection option SW
0: Pin positioning
1: Pin/edge positioning
0
OFFFAA
(06802A)
7FFAA Skip recovery option SW
0: Not available
1: Available
0
0FFFAC
(06802C)
7FFAC Auto recovery option SW
0: Not available
1: Available
2: Available (Outputs R3NG command to host)
1
0FFFAE
(06802C)
7FFAE Skip + auto recovery option SW
0: Not available
1: Available
0
0FFFB0
(068030)
7FFB0 4−direction component invert device connection option SW
(Component invert command and polar coordinate pattern cannot be
used if this SW is not ON.)
0: Not connected
1: Connected
0
OFFFB8
(068038)
7FFB8 Inch pitch SW
0: mm pitch model
1: inch pitch model
Pitch
mm Inch
2.5
5.0
7.5
10.0
2.5 mm
5.0 mm
7.5 mm
10.0 mm
2.54 mm
5.08 mm
7.62 mm
10.16 mm
0

8.2 List of Software Settings
SERVICE MANUAL
RH5
8.2−3
DA3SEC−85−470−B0
Real
ROM
address
Description Default
0FFFBA
(06803A)
7FFBA Width adjusting axis motor connection SW (Also indicates the presence
of semiauto/auto width adjusting motor.)
Bit 0: Width adjust loader axis
Bit 1: Width adjust X−Y table axis
Bit 2: Width adjust unloader axis
Bit 3: Width adjust reference pin axis
Bit value = 1: Axis exists
0: no axis
(Ex.) Loader and unloader axes only = 05
All axes except reference pin axis = 07
4 axes (all axes) = 0F
0
0FFFBC
(06803C)
7FFBC Component invert unit type SW (Available only when the machine is
RHXP and the invert unit is connected.)
0: 5.0/7.5 mm
1: 7.5/10 mm
0
0FFFBE
(06803E)
7FFBE M1000 l M10 data convert command SW
(When converting P770 NC data into P791, if this SW is 1, M100 data
will be converted to M10 and vice versa for RHP model.)
0: M10 l M100 without conversion
1: M10 l M100 convert available
0
0FFFC0
(068040)
7FFC0 Applicable SW for special 2.5/3.5 mm pitch
(Enables component insertion on 2.5/3.5 mm pitch exclusive model
using M1 command.)
0
0FFFC2
(068042)
0FFFC3
(068042)
7FFC2
7FFC3
Special 2.5/3.5 mm pitch data
(Available only when the above special switch is ON.)
2.5 mm pitch data
7FFC2: C4 9C4 (2500)
7FFC3: 09
3.5 mm pitch data
7FFC2: AC DAC (3500)
7FFC3: 0D
AC
0D
0FFFC4
(068044)
7FFC4 Reverse board flow (L o R) machine SW
0: Flow direction L m R (standard type)
1: Flow direction L o R (standard type)
2: Flow direction L o R (special version)
0
0FFFC8
(068048)
7FFC8 Graphic (GRA) board connection option SW
0: Not connected
1: Connected
0
0FFFCA
(06804A)
7FFCA NG board punching unit connection option SW
(Indicates whether or not the board punching unit is connected to RH5.
When skip recovery mode is selected, the punching unit is used at the
unloader exit to punch (or mark) the boards out which have been
skipped due to insertion error.)
0: Not connected
1: Connected
0
0FFFCC
(06804C)
7FFCC PH error detection option SW
(This switch may bring the machine to a 1 block stop when the
component sensor detects a component by mistake when the CS5
sensor is ON. It sets a flag on SEQ link table. This flag can be
overwritten on the monitoring screen, just the same as ignoring
insertion detection.)
0: PH error invalid
1: PH error valid
1