Q170226E01.pdf - 第309页

RH5 8.3 List of Jumper Switch Settings SERVICE MANUAL 8.3−12 DA3SEC−85−540−B0 (8) Pulse motor general−purpose input logic (When sub−board aboard) JP7 Open: INS signal ‘H’ level Short: INS signal ‘L ’ level =REFERENCE= Fa…

100%1 / 392
8.3 List of Jumper Switch Settings
SERVICE MANUAL
RH5
8.3−11
DA3SEC−85−540−B0
(4) Character generator ROM capacity
JP6
Memory capacity
128 KB
256 KB
=REFERENCE=
Factory setting: 128 KB
(5) Pulse motor pulse output logic (When sub−board aboard)
JP5
Open: Pulse output active ‘H’
Short: Pulse output active ‘L
=REFERENCE=
Factory setting: Pulse output active ‘L
(6) Pulse motor direction output logic (When sub−board aboard)
JP9
Open: ‘L level is in the + direction
Short: ‘H’ level is in the + direction
=REFERENCE=
Factory setting: ‘L level in the + direction
(7) Pulse motor ORG input logic (When sub−board aboard)
JP6
Open: ORG−D1 ‘H’ level is ON.
Short: ORG−D1 ‘L level is ON.
=REFERENCE=
Factory setting: ‘L level is in the + direction
RH5
8.3 List of Jumper Switch Settings
SERVICE MANUAL
8.3−12
DA3SEC−85−540−B0
(8) Pulse motor general−purpose input logic (When sub−board aboard)
JP7
Open: INS signal ‘H’ level
Short: INS signal ‘L level
=REFERENCE=
Factory setting: ‘H’ level
8.3 List of Jumper Switch Settings
SERVICE MANUAL
RH5
8.3−13
DA3SEC−85−540−B0
8.3.3 RCG (I) Board Setting (X984 211)