Q170226E01.pdf - 第307页
RH5 8.3 List of Jumper Switch Settings SERVICE MANUAL 8.3−10 DA3SEC−85−540−B0 Jumper switch settings (1) Memory (program ROM) capacity JP1 JP2 JP3 Memory capacity 256 K 512 KB 1M B =REFERENCE= Factory setting: 1 MB (2) W…

8.3 List of Jumper Switch Settings
SERVICE MANUAL
RH5
8.3−9
DA3SEC−85−540−B0
DIP switch settings
(1) SW1: For setting multibus interrupt level
Bit 7
Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Interrupt
level
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
INT0
INT1
INT2
INT3
INT4
INT5
INT6
INT7
=REFERENCE=
SW1 factory setting: INT6
(2) SW2 (Transfer function setting with RS−232C)
Not specified (reserved for
general−purpose use setting)
Word configuration
selection
Baud rate
07
ON
OFF
Bit 4 Bit 3 Bit 2 Word configuration
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
7 bit Even 2 stop bit
7 bit Odd 2 stop bit
7 bit Even 1 stop bit
7 bit Odd 1 stop bit
8 bit 2 stop bit
8 bit 1 stop bit
8 bit Even 1 stop bit
8 bit Odd 1 stop bit
Bit 1 Bit 0 Baud rate
OFF
OFF
ON
ON
OFF
ON
OFF
ON
2400 bps
4800 bps
9600 bps
19200 bps
=REFERENCE=
x SW2 factory setting: All bits are OFF
x Transfer function with RS−232C can be applied only for the machine, but not for the software.

RH5
8.3 List of Jumper Switch Settings
SERVICE MANUAL
8.3−10
DA3SEC−85−540−B0
Jumper switch settings
(1) Memory (program ROM) capacity
JP1
JP2
JP3
Memory capacity
256 K
512 KB
1MB
=REFERENCE=
Factory setting: 1 MB
(2) Watchdog timer ON/OFF
JP4
JP7
Watchdog timer ON
Watchdog timer OFF
(For testing)
=REFERENCE=
x Factory setting: ON
x The program shall be changed with the watchdog timer being OFF.
(3) Character font
JP5
Short: 2 x 2 byte character
Open: 1 byte character
=REFERENCE=
x Factory setting: 2 x 2 byte character
x The program shall be changed with 1 byte character being used.

8.3 List of Jumper Switch Settings
SERVICE MANUAL
RH5
8.3−11
DA3SEC−85−540−B0
(4) Character generator ROM capacity
JP6
Memory capacity
128 KB
256 KB
=REFERENCE=
Factory setting: 128 KB
(5) Pulse motor pulse output logic (When sub−board aboard)
JP5
Open: Pulse output active ‘H’
Short: Pulse output active ‘L’
=REFERENCE=
Factory setting: Pulse output active ‘L’
(6) Pulse motor direction output logic (When sub−board aboard)
JP9
Open: ‘L’ level is in the + direction
Short: ‘H’ level is in the + direction
=REFERENCE=
Factory setting: ‘L’ level in the + direction
(7) Pulse motor ORG input logic (When sub−board aboard)
JP6
Open: ORG−D1 ‘H’ level is ON.
Short: ORG−D1 ‘L’ level is ON.
=REFERENCE=
Factory setting: ‘L’ level is in the + direction