RH5 3.1 Outline of Installation SERVICE MANUAL 3.1−6 DA3SEC−1 1−010−A0 3.1.5 Connecting the Air Supply Connect the primary air piping to the machine. Make sure that the primary air pressure is more than 0.5 MPa and flowr…

3.1 Outline of Installation
SERVICE MANUAL
RH5
3.1−5
DA3SEC−11−010−A0
3.1.4 Safeguards and Warning Lamps
Be sure to install the safeguards and warning lamps.
=REFERENCE=
Refer to ’SAFETY’ for safety interlock arrangement.
Safeguard
Warning lamp
(NM−8244A,B,C)
(NM−8245A,B,C)
3,296 (NM−8244A, NM−8245A)
4,146 (NM−8244B, NM−8245B)
5,160 (NM−8244C, NM−8245C)
1,860 (NM−8244A,B,C)
2,025 (NM−8245A,B,C)
3,296 (NM−8244A, NM−8245A)
4,146 (NM−8244B, NM−8245B)
5,160 (NM−8244C, NM−8245C)
(NM−8244A,B,C)
(NM−8245A,B,C)
660
797
1,200: M
1,228: LL
1,650 (NM−8244A,B,C)
1,600 (NM−8245A,B,C)
1,950 (NM−8244A,B,C)
1,900 (NM−8245A,B,C)

RH5
3.1 Outline of Installation
SERVICE MANUAL
3.1−6
DA3SEC−11−010−A0
3.1.5 Connecting the Air Supply
Connect the primary air piping to the machine.
Make sure that the primary air pressure is more than 0.5 MPa and flowrate more
than 120 L/min (A.N.R).
=CHECK=
The primary air shall have no foreign substances such as moisture.
After completing the piping connection, supply the primary air, and adjust it to 0.5 MPa
using the MR unit.
Primary side air piping
connection

3.2 Connecting the Power Supply
SERVICE MANUAL
RH5
3.2−1
DA3SEC−11−020−A0
3.2 Connecting the Power Supply
DA3SEC−11−020−A0
Sentence No.
3.2.1 Connecting the Cables
During installation of the machine, connect the power source and the machine by cable. The following
diagram shows the power input circuit.
Connect the distribution panel, the main switch, and the machine as indicated in the diagram.
To be provided by the
user.
Cables come with the machine
Distribution
panel
Main switch
Machine
Power source unit
Transformer
Connecting the cable
Power supply cable
grounding cable
Wire must be fixed
=CHECK=
The machine’s electrical power volume is three−phase AC 200V 5kVA. When connecting cable to
the main switch, take care to satisfy the requirement for the distribution panel installation.