8.3 List of Jumper Switch Settings SERVICE MANUAL RH5 8.3−15 DA3SEC−85−540−B0 Jumper switch settings (1) JP4, JP7 (Fixed) JP4 JP7 1 1 (2) JZ1, JZ2 (Fixed) JZ4 JZ2 1 1 (3) Camera cable (Fixed) JZ3 JZ4 1 1 When Straight ca…

RH5
8.3 List of Jumper Switch Settings
SERVICE MANUAL
8.3−14
DA3SEC−85−540−B0
DIP switch settings
(1) SW1: multibus interrupt level setting
Bit 7
Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Interrupt
level
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
INT0
INT1
INT2
INT3
INT4
INT5
INT6
INT7
=REFERENCE=
SW1 factory setting: INT6
SW2 (operation mode [Compatible ROM version] setting)
Bit 5 Bit 6 Bit 7 Operation mode
OFF
ON
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
Version: under 1.14
Version: 1.14T2
Version: 1.15
Version: over 1.16
=REFERENCE=
x Bit 0 − 4: Not used
x Factory setting: Bit 5 and 6 are ON. Others are OFF.

8.3 List of Jumper Switch Settings
SERVICE MANUAL
RH5
8.3−15
DA3SEC−85−540−B0
Jumper switch settings
(1) JP4, JP7 (Fixed)
JP4
JP7
1
1
(2) JZ1, JZ2 (Fixed)
JZ4
JZ2
1
1
(3) Camera cable (Fixed)
JZ3
JZ4
1
1
When Straight cable is used.
When L type cable is used.
=REFERENCE=
x Factory setting is for Straight cable

RH5
8.3 List of Jumper Switch Settings
SERVICE MANUAL
8.3−16
DA3SEC−85−540−B0
8.3.4 MIOE (I) Board Setting
SW1: Generates reset signal.
1 2 3 BPS
0 0 0 9600
1 0 0 4800
0 1 0 2400
1 1 0 1200
0 0 1 600
1 0 1 300
4: Brake character
ON: Output
OFF: Not output
5: Checksum
ON: Yes
OFF: No
6: R recommend
ON: Output
OFF: No output
7: Time out
ON: Yes
OFF: No
8: End code
ON: CR
OFF: ETX
1:
2:
3:
4:
5:
6:
7:
8:
=REFERENCE=
JP17 (FDD) setting
For PC98 series For IBM PC series
JP17 − 1: Open JP17 − 1: Open
JP17 − 2: Short JP17 − 2: Open
JP17 − 3: Open JP17 − 3: Open