XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第230页

1.2 OPERA TION _BrightLevelArrv – [Explanation] Not used [Default] 0 _TrayDetectMotion – [Explanation] Not used. [Default] 0 _GateMotionSwitch 0:1:2 O [Explanation] Placement settings 0: Use sequence data settings 1: Arc…

100%1 / 344
_ConvOutSensor 0:1 X
[Explanation] Conveyor-out station sensor specifications
0: Unsupported
1: Supported
[Default] 1
_BackupPlateSensor 0:1 X
[Explanation] Backup plate interference prevention sensor
0: Not supported
1: Supported
[Default] 0
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-3 XP-142E System Reference
1.2 OPERATION
_BrightLevelArrv
[Explanation] Not used
[Default] 0
_TrayDetectMotion
[Explanation] Not used.
[Default] 0
_GateMotionSwitch 0:1:2 O
[Explanation] Placement settings
0: Use sequence data settings
1: Arch motion
2: Gate motion
[Default] 0
_DisposeWaitTime
[Explanation] Not used.
[Default] 0
_TrayAbsorbTime
[Explanation] Not used.
[Default] 0
_DisposeConvSide
[Explanation] Not used.
[Default] 0
_ResetCylORTime
[Explanation] Not used.
[Default] 0
_PlaceDownEndTimer X
[Explanation] Sets the down limit timer at placing operation (msec).
[Default] 0
_DeviceSetChkUse 0:1:2:3 O
[Explanation] Specifies the part resupply confirmation method.
0: Automatic part resupply
1, 2: Manual part resupply
(Using the machine information screen for parts out or missed pick-
up)
3: Manual part resupply
(Using the machine information screen for parts out, missed pick-up,
or vision processing error)
[Default] 3
_ConvErrTime 0:60000 X
[Explanation] Sets the next stage arrival confirmation timer (msec).
0: 10000 (msec)
The value 1000 is used for all settings below 1000 (msec).
[Default] 0
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-4 XP-142E System Reference
_ConveyerMode 0:1:2 O
[Explanation] Specifies the conveyor mode
0: Same setting as 1.
1: Standard
(Acquire after main conveyor’s panel pass sensor switches on.)
2: Special (Acquire after unloading)
[Default] 1
_ConveyerPassMode 0:1 O
[Explanation] Specifies the conveyor pass mode
0: Normal pass mode (Clamped on main lifter)
1: No clamp mode (Not clamped on main lifter)
[Default] 0
_PickUpTimerSide1
[Explanation] Not used
[Default] 0
_PickUpTimerSide2
[Explanation] Not used.
[Default] 0
_PickVaccumStartTime
[Explanation] Not used.
[Default] 0
_VacuumDesTime
[Explanation] Not used.
[Default] 0
_VT130ImageProcTwice
[Explanation] Not used.
[Default] 0
_TrayEjectCheck
[Explanation] Not used.
[Default] 0
_DesStartTime
[Explanation] Not used.
[Default] 0
_MultiImageNotDisp
[Explanation] Not used.
[Default] 0
_ConvMtrSpeed X
[Explanation] Sets the panel conveyance speed (mm/sec)
[Default] 340 (“340” is also adopted if the setting is “0”)
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-5 XP-142E System Reference