XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第233页
1.3 SERVO_OFST _targetOfst_X XR [Explanation] Absolute encoder offset (mm). [Default] Proper data measurement result. _targetOfst_Y XR [Explanation] Absolute encoder offset (mm). [Default] Proper data measurement result.…

_BlackMaskLevel -1 ~ 255 X
[Explanation] Sets the noise eliminating level when vision processing parts.
Recognizes brightness levels lower than that specified for part image
processing as being the same brightness, and eliminates noise.
-1: Automatic setting
[Default] -1
_PCFtpUse 0:1 O
[Explanation] Specifies the remote file
0: Disabled
1: Enabled
[Default] 0
_TemplateFind 1:2:3 O
[Explanation] Specifies the conditions for Vision Type 18 template file name search.
0,1: Part No. priority
2: Part type priority
3: Only part type is referenced
Note: Do not set to “0”.
[Default] 3
_MainLifterUpEndTimer O
[Explanation] Sets the waiting period (msec) for lifter UP motion. (Used when image
acquisition occurs before panel clamping is completed.)
[Default] 350
_FiducialLampOnTimer 0 ~ 1000 O
[Explanation] Sets the waiting period (msec) for lamp ON completion. (Used when
image acquisition occurs before the fiducial camera’s brightness has
stabilized.)
[Default] 0
_MainStArrvFDChkFlag –
[Explanation] Not used.
[Default] 0
_ThermalOffsetTime O
[Explanation] Sets the time interval between thermal expansion compensation
measurements when producing one panel. (msec)
Set “0” to disable thermal expansion compensation.
[Default] 0
_ThermalOffsetMark 0:1 O
[Explanation] Specifies the thermal offset reference marks
0: Fiducial marks
1: Position offset marks on the machine
[Default] 0
_NoNzlPosOffset –
[Explanation] Not used.
[Default] 0
_VcmBreakChkTime –
[Explanation] Not used.
[Default] 0
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-6 XP-142E System Reference

1.3 SERVO_OFST
_targetOfst_X XR
[Explanation] Absolute encoder offset (mm).
[Default] Proper data measurement result.
_targetOfst_Y XR
[Explanation] Absolute encoder offset (mm).
[Default] Proper data measurement result.
_targetOfst_Z XR
[Explanation] Absolute encoder offset (mm).
[Default] Proper data measurement result.
_targetOfst_Q XR
[Explanation] Absolute encoder offset (mm).
[Default] Proper data measurement result.
_targetOfst_R XR
[Explanation] Absolute encoder offset (mm).
[Default] Proper data measurement result.
_targetOfst_T –
[Explanation] Not used.
[Default] 0
_targetOfst_U –
[Explanation] Not used.
[Default] 0
_targetOfst_F XR
[Explanation] Absolute encoder offset (mm).
[Default] Proper data measurement result.
_targetOfst_G XR
[Explanation] Absolute encoder offset (mm).
[Default] Proper data measurement result.
_TestOption –
[Explanation] Not used.
[Default] 0
X_StbTimeFast X
[Explanation] Sets the time (msec) for the X-axis to stabilize when in fast mode.
[Default] Proper data measurement result.
Y_StbTimeFast X
[Explanation] Sets the time (msec) for the Y-axis to stabilize when in fast mode.
[Default] Proper data measurement result.
R_StbTimeFast X
[Explanation] Sets the time (msec) for the R-axis to stabilize when in fast mode.
[Default] Proper data measurement result.
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-7 XP-142E System Reference

Q_StbTimeFast X
[Explanation] Sets the time (msec) for the Q-axis to stabilize when in fast mode.
[Default] Proper data measurement result.
X_StbTimeSlow X
[Explanation] Sets the time (msec) for the X-axis to stabilize when in slow mode.
[Default] Proper data measurement result.
Y_StbTimeSlow X
[Explanation] Sets the time (msec) for the Y-axis to stabilize when in slow mode.
[Default] Proper data measurement result.
R_StbTimeSlow X
[Explanation] Sets the time (msec) for the R-axis to stabilize when in slow mode.
[Default] Proper data measurement result.
Q_StbTimeSlow X
[Explanation] Sets the time (msec) for theQ-axis to stabilize when in slow mode.
[Default] Proper data measurement result.
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-8 XP-142E System Reference