XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第318页
Code: 12052061 Display: Servo System Error Cause: Servo System Error Remedy: Internal error. This error should not occur under normal circumstances. Take a machine trace and send it to your Fuji representative. Code: 120…

Code: 12052058
Display: Minus Limit overtravel.
Cause: An axis has passed the minus limit.
Remedy: The software limit may be incorrect. Move the axis to the mechanical stopper and
confirm the software limit position is correct.
Code: 12052059
Display: Deviation over.
Cause: It is possible that the axis has collided with something.
Remedy: Check for any obstacles that may have caused an axis collision. If the axis is
against a mechanical stopper, check the calibration data is correct.
Code: 1205205A
Display: Deviation over
Cause: It is possible that the axis has collided with something.
Remedy: Check for any obstacles that may have caused an axis collision. If the axis is
against a mechanical stopper, check the calibration data is correct.
Code: 1205205B
Display: Servo System Error
Cause: Servo System Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 1205205C
Display: Servo System Error
Cause: Servo System Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 1205205D
Display: Servo System Error
Cause: Servo System Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 1205205E
Display: Servo System Error
Cause: Servo System Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 1205205F
Display: Servo System Error
Cause: Servo System Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12052060
Display: Servo System Error
Cause: Servo System Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Part 8 Chapter 1 Error Codes and Corrective Measures
Edition 2.0 8-1-29 XP-142E System Reference

Code: 12052061
Display: Servo System Error
Cause: Servo System Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12052062
Display: Servo System Error
Cause: Servo System Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12052063
Display: Servo System Error
Cause: Servo System Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12052064
Display: Servo System Error
Cause: Servo System Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12052065
Display: Servo System Error
Cause: Servo System Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12052066
Display: Servo System Error
Cause: Servo System Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12052067
Display: Servo System Error
Cause: Servo System Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12052068
Display: EMERGENCY STOP has occurred.
Cause: EMERGENCY STOP has occurred.
Remedy: Clear the error status.
Code: 1205206A
Display: A servo alarm has occurred. Check the servo amp alarm display and restart the
machine.
Cause: A servo alarm has occurred.
Remedy: Check the servo amp alarm display and restart the machine.
Part 8 Chapter 1 Error Code Messages and Corrective Measures
Edition 2.0 8-1-30 XP-142E System Reference

Code: 1205501B
Display: A cycle steal compatible nozzle is not present.
Cause: A cycle steal compatible nozzle is not present.
Remedy: Set a cycle steal compatible nozzle.
Code: 12055026
Display: The cycle steal offset tolerance has been exceeded.
Cause: The cycle steal offset tolerance has been exceeded.
Remedy: Execute the Rotate Center command.
Code: 1205602A
Display: Operating System Error
Cause: Operating System Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 1205602B
Display: Raised nozzle detected. Check nozzle station.
Cause: The raised nozzle detection sensor was interrupted.
Remedy: If this error occurred incorrectly, confirm the sensor’s ON/OFF operation, and
adjustment position are correct.
Code: 1205602C
Display: The remover is not set correctly. Check the remover station.
Cause: The remover station sensor was interrupted.
Remedy: If this error occurred incorrectly, confirm the sensor’s ON/OFF operation, and
adjustment position are correct.
Code: 12056030
Display: The slot number for the tray on the shuttle is unknown.
Unable to retract the tray.
Close this error message and select the current tray slot number in the displayed
dialog.
Cause: The slot number for the tray on the shuttle is unknown.
Remedy: Close this error message and input the current tray slot number in the displayed
dialog.
Code: 12056031
Display: The remover is interfering with the tray positioning plate when ejecting the tray.
Cause: The remover is interfering with the tray positioning plate. Trays whose Tray
Length (X-direction) is shorter than the remover cannot be ejected using the
standard XP tray holder.
Remedy: Either change the [Tray Type] setting in part data to a type that does not
automatically eject trays (4), or use a precise tray.
Code: 12056032
Display: The remover is interfering with the tray positioning plate when ejecting the tray.
Cause: The remover is interfering with the tray positioning plate.
Trays whose Tray Width (Y-direction) is shorter than the remover cannot be
ejected using the standard XP tray holder.
Remedy: Either change the [Tray Type] in part data to a type that does not automatically
eject trays (4), or use a precise tray.
Part 8 Chapter 1 Error Codes and Corrective Measures
Edition 2.0 8-1-31 XP-142E System Reference