XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第309页

Code: 120501BB Display: Unable to retract the shuttle. A retracted tray already exists. Confirm the tray pallet position. Close this error message and input the current tray slot number in the displayed dialog. Cause: An…

100%1 / 344
Code: 120501B2
Display: Reset cylinder movement error.
Cause: The reset cylinder up or down movement has not been confirmed.
Remedy: Check the reset cylinder raised confirmation sensor.
The nozzle piston may be locked.
Push down on the nozzle piston to check its vertical movement.
Code: 120501B3
Display: Backup pin interference sensor activated.
Cause: Backup pin interference sensor activated.
Remedy: Correct the position of the backup pin.
Check the backup pin interference sensor is functioning correctly.
Code: 120501B4
Display: A thermal abnormality has occurred. Check the following item.
Cause: A thermal abnormality was detected.
Remedy: Check the X- and Y-axis regenerative resistance temperature fuse and vacuum
pump temperature fuse functions (XP-141, XP-142). Check the motor thermal
relay for the vacuum pump (XP-141, XP-142).
Code: 120501B6
Display: Limit over (Pick-up position)
Cause: Limit over (Pick-up position).
Remedy: Check the corrected pick-up value and pick-up point offset.
Code: 120501B7
Display: Limit over (Pick-up position)
Cause: Z limit over (Pick-up position)
Remedy: Check the pick-up point offset Z.
Code: 120501B8
Display: An empty tray dropped during tray ejection.
Cause: The tray pick-up sensor switched OFF during tray ejection.
Remedy: Remove the empty tray from the interior of the machine.
Code: 120501B9
Display: The pick-up measurement position exceeds the servo limit.
Cause: The pick-up measurement position exceeds the servo limit.
Remedy: Check that the servo limit specified in the calibration data is correct.
If the servo limit is correct, machine modifications are required to extend the servo
limit, making measurement possible.
For machines that have not been modified, disable this function by setting the
calibration data item “_PickPosAutoMeasure” to “0”.
Code: 120501BA
Display: Unable to advance the shuttle.
An advanced tray already exists.
Confirm the tray pallet position.
Cause: An advanced tray already exists.
The shuttle cannot advance because the tray advance position sensor is OFF.
Remedy: Confirm the tray pallet position.
Check the tray advance position sensor is functioning correctly.
Part 8 Chapter 1 Error Code Messages and Corrective Measures
Edition 2.0 8-1-20 XP-142E System Reference
Code: 120501BB
Display: Unable to retract the shuttle.
A retracted tray already exists.
Confirm the tray pallet position.
Close this error message and input the current tray slot number in the displayed
dialog.
Cause: An attempt was made to retract the shuttle, however, the tray pallet is already
retracted.
Remedy: Confirm the tray pallet position.
Check the tray advance position and tray retract position sensors are functioning
correctly.
Close this error message and input the current tray slot number in the displayed
dialog.
Code: 120501BC
Display: The tray pusher cannot be advanced.
Confirm the tray pusher position.
Cause: An attempt was made to advance the tray pusher, however the tray pusher retract
sensor did not turn off within the required time period.
Remedy: Confirm the tray pusher position.
Check that the tray pusher advance and retract confirmation sensors are
functioning correctly.
Code: 120501BD
Display: The tray pusher cannot be advanced.
Confirm the tray pusher position.
Cause: An attempt was made to retract the tray pusher after it advanced, however the
tray pusher advance confirmation sensor did not turn on within the required time
period.
Remedy: Confirm the tray pusher position.
Check that the tray pusher advance and retract confirmation sensors are
functioning correctly.
Code: 120501BE
Display: The tray pusher cannot be retracted.
Confirm the tray pusher position.
Cause: An attempt was made to retract the tray pusher, however the tray pusher advance
confirmation sensor remained ON for the required time period.
Remedy: Confirm the tray pusher position.
Check that the tray pusher advance and retract confirmation sensors are
functioning correctly.
Code: 120501BF
Display: The tray pusher cannot be retracted.
Confirm the tray pusher position.
Cause: An attempt was made to retract the tray pusher, however, after the tray pusher
advance sensor turned OFF, the tray pusher retract confirmation sensor remained
OFF for the required time period.
Remedy: Confirm the tray pusher position.
Check that the tray pusher retract and advance confirmation sensors are
functioning correctly.
Part 8 Chapter 1 Error Codes and Corrective Measures
Edition 2.0 8-1-21 XP-142E System Reference
Code: 120501C0
Display: The tray shutter is open.
Cause: The tray shutter open sensor is OFF.
Remedy: Check that the tray shutter is closed.
Check that the tray shutter position sensor is functioning correctly.
Code: 120501C1
Display: The tray shuttle is not at the origin position.
The elevator cannot be moved.
Confirm the tray shuttle position.
Cause: Because the tray shuttle is not at the origin position the tray cannot be moved on
the elevator.
Remedy: Confirm the tray shuttle position.
Check that the tray shuttle position sensor is functioning correctly.
Code: 120501C2
Display: The tray shuttle position confirmation sensor turned off while the elevator was
moving.
The elevator cannot be moved.
Confirm the tray shuttle position.
Cause: The magazine tray check sensor turned off while the elevator was moving.
Remedy: Confirm the tray shuttle position.
Check that the tray shuttle position sensor is functioning correctly.
Code: 120501C3
Display: The U-axis interlock sensor is blocked.
Cause: The U-axis interlock sensor was blocked while the shuttle was moving.
Remedy: Check that nothing is on top of the tray pallet.
Check that the U-axis interlock sensor is functioning correctly.
Code: 120501C4
Display: Tray parts cannot be picked up from the specified slot. Reduce the number of
trays.
Cause: Tray parts cannot be picked up from the specified slot.
Remedy: Reduce the number of trays.
Code: 120501C5
Display: The head cannot pass over a tray when picking up adjacent tray parts as the tray
height for the specified slot is too high. Reduce the number of trays.
Cause: The head cannot pass over a tray when picking up adjacent tray parts as the tray
height for the specified slot is too high.
Remedy: Reduce the number of trays.
Code: 120501C6
Display: The head cannot pass over a tray when ejecting the specified tray. Reduce the
number of trays.
Cause: The head cannot pass over a tray when ejecting the specified tray.
Remedy: Reduce the number of trays.
Part 8 Chapter 1 Error Code Messages and Corrective Measures
Edition 2.0 8-1-22 XP-142E System Reference