6.2.2 Production Information Display Conditions Setting Screen Data Explanation This screen can be used to specify the time frame for the development of production information, and to select programs. Click the [X] butto…

6.2 Screen Operations
6.2.1 Switching Between Screens
To display the production information, select [Production] at the main menu, then select
[Display Production Information] at the sub-menu to display the production information
display conditions setting screen where the display conditions can be set. After
specifying these settings, select the production program to be displayed, and then click
the various buttons to proceed to the corresponding information screens.
Click [Log File] to display the log file selection screen. Select the desired log file(s), then
press the various buttons to proceed to the corresponding information screens.
Production Information Display Conditions Setting screen
Log File Selection screen
Automatic Deletion Function Setting screen
Panel Information screen
Machine Status Information screen
Feeder Information screen
Nozzle Information screen
Error Information screen
Panel Information screen
Machine Status Information screen
Feeder Information screen
Nozzle Information screen
Error Information screen
XP1S2067E
Part 2 Chapter 6 Production Information Display
Edition 2.0 2-6-3 XP-142E System Reference

6.2.2 Production Information Display Conditions Setting Screen
Data Explanation
This screen can be used to specify the time frame for the development of production
information, and to select programs. Click the [X] button to enable a time frame (the
button indicator changes to [O]). If no time frame is to be set, click the button again to
change the button indicator to [X].
The names of production programs are obtained from a log file stored in the
current/sd0FUJI/USER/PRODUCT folder, and display in the window shown above.
From this list, select the name of the program which contains the information to be
displayed.
When a program is selected, the program operation time for the unselected programs
becomes "power off time". To make selections in log file units, click [Log File] to change
to the Log File selection screen.
Part 2 Chapter 6 Production Information Display
Edition 2.0 2-6-4 XP-142E System Reference

Operation Button Explanations
Proceeds to the panel information screen.
Proceeds to the machine status information screen.
Proceeds to the feeder information screen.
Proceeds to the nozzle information screen.
Proceeds to the error information screen.
Develops the production information in accordance with the
currently specified conditions, and saves it to a floppy disk.
Although the default file name for the saved data is "PRODINFO",
the name be changed at the dialog box shown below.
Proceeds to the log file selection screen.
Part 2 Chapter 6 Production Information Display
Edition 2.0 2-6-5 XP-142E System Reference