XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第324页

Code: 1230030F Display: Socket transmission error Cause: A port that is already connected is selected as the communication port. Remedy: Check the communication port numbers of the IJ process and intermediate machines. C…

100%1 / 344
Code: 12300306
Display: Socket transmission error
Cause: Socket transmission error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12300307
Display: Socket transmission error
Cause: Socket is invalid, or unable to connect or call machine.
Remedy: Check connecting terminal and status of machine.
Check main machine and connecting terminal network cables connections.
Code: 12300308
Display: Socket transmission error
Cause: The machine configurations are different on the IJ process side and machine side.
Remedy: Confirm machine configuration.
Code: 12300309
Display: Socket transmission error
Cause: The communication socket is invalid.
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 1230030A
Display: Socket transmission error
Cause: Unable to receive message
Remedy: Check status of connecting terminal and machine.
Check the machine and connecting terminal network cables connections.
Code: 1230030B
Display: Socket transmission error
Cause: Unable to receive message
Remedy: Check status of connecting terminal and machine.
Check the machine and connecting terminal network cables connections.
Code: 1230030C
Display: Socket transmission error
Cause: During automatic changeover, the user name for the FTP server that outputs the
production program is not valid.
Remedy: Check the FTP server user name.
Code: 1230030D
Display: Socket transmission error
Cause: During automatic changeover, the password for the FTP server that outputs the
production program is not valid.
Remedy: Check the FTP server password.
Code: 1230030E
Display: Socket transmission error
Cause: An invalid message was received.
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Part 8 Chapter 1 Error Codes and Corrective Measures
Edition 2.0 8-1-35 XP-142E System Reference
Code: 1230030F
Display: Socket transmission error
Cause: A port that is already connected is selected as the communication port.
Remedy: Check the communication port numbers of the IJ process and intermediate
machines.
Code: 12300310
Display: Socket transmission error
Cause: Received an invalid command.
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12300311
Display: Socket transmission error
Cause: Received an invalid command.
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12300312
Display: Socket transmission error
Cause: Job data not specified.
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12300313
Display: Socket transmission error
Cause: Cannot locate connection socket.
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12300314
Display: Socket transmission error
Cause: Panel ID not specified.
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12300315
Display: Socket transmission error
Cause: The machine number of the sub-machine used for automatic changeover is out of
range.
Remedy: Check the number of automatic changeover machines in the automatic changeover
settings.
Code: 12300316
Display: Socket transmission error
Cause: Unable to secure socket transmission memory.
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Part 8 Chapter 1 Error Code Messages and Corrective Measures
Edition 2.0 8-1-36 XP-142E System Reference
Code: 12300317
Display: Socket transmission error
Cause: Socket communication time out.
Remedy: Check the machine and connecting terminal network cables connections.
Check the status of connecting terminal and machine.
Code: 14011000
Display: Fiducial mark read error
Cause: Fiducial mark read error
Remedy: Check the correct mark data has been input. Confirm the program coordinates
and actual mark location correspond correctly. Check the mark is not dirty or
obstructed.
Code: 14011001
Display: Area check detected a value outside the permissible range
Cause: Area check detected a value outside the permissible range.
Remedy: Confirm the program coordinates and actual mark location correspond correctly.
The mark may have been read incorrectly.
Code: 14011002
Display: Pitch check detected a value outside the permissible range
Cause: Pitch check detected a value outside the permissible range.
Remedy: Confirm the program coordinates and actual mark location correspond correctly.
The mark may have been read incorrectly.
Code: 14011003
Display: Failed to read reference mark during cycle steal.
Cause: Failed to read reference mark during cycle steal.
Remedy: Check that the reference mark is clean.
Code: 14011004
Display: The reference mark deviation is more than 1mm. Re-measure the reference mark.
Cause: The calibration data value for the reference mark does not match the origin
position.
Remedy: Re-measure the reference mark and, if necessary, the origin position.
Code: 14011005
Display: Failed to acquire image of the reference mark.
Cause: Failed to acquire image of the reference mark.
Remedy: Check that the reference mark is not soiled, and check the reference mark
calibration data settings.
Code: 14011006
Display: A precise tray reference mark could not be found.
Cause: If the tray that was read is a precise tray, then either the mark is dirty or its
position is too far from the reference position.
If the tray is a reference tray, then the precise tray check sensor is out of
adjustment.
Remedy: For precise trays, check that the mark is clean.
Eliminate any play from the shuttle.
For standard trays, adjust the precise tray check sensor (X045).
Part 8 Chapter 1 Error Codes and Corrective Measures
Edition 2.0 8-1-37 XP-142E System Reference