XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第242页
1.9 SIG_TOWER_DELA Y_TIMER _WaitPanelOnDelayTimer 0 ~ 300 O [Explanation] Sets the delay timer (sec) for waiting for a panel. [Default] 0 _WaitNextMcOnDelayTimer 0 ~ 300 O [Explanation] Sets the delay timer (sec) for wai…

1.8 CAMERA_UNIT
_Camera0UnitX X
[Explanation] Sets the camera no. 0 unit value X.
[Default] Proper data measurement result.
_Camera0UnitY X
[Explanation] Sets the camera no. 0 unit value Y.
[Default] Proper data measurement result.
_Camera1UnitX X
[Explanation] Sets the camera no. 1 unit value X.
[Default] Proper data measurement result.
_Camera1UnitY X
[Explanation] Sets the camera no. 1 unit value Y.
[Default] Proper data measurement result.
_Camera1UnitX_Low X
[Explanation] Sets the camera no. 1 unit low poisition value X.
[Default] Proper data measurement result.
_Camera1UnitY_Low X
[Explanation] Sets the camera no. 1 unit low position value Y.
[Default] Proper data measurement result.
_Camera2UnitX X
[Explanation] Sets the camera no. 2 unit value X.
[Default] Proper data measurement result.
_Camera2UnitY X
[Explanation] Sets the camera no. 2 unit value Y.
[Default] Proper data measurement result.
_Camera3UnitX X
[Explanation] Sets the camera no. 3 unit value X.
[Default] Proper data measurement result.
_Camera3UnitY X
[Explanation] Sets the camera no. 3 unit value Y.
[Default] Proper data measurement result.
_Camera4UnitX X
[Explanation] Sets the camera no. 4 unit value X.
[Default] Proper data measurement result.
_Camera4UnitY X
[Explanation] Sets the camera no. 4 unit value Y.
[Default] Proper data measurement result.
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-15 XP-142E System Reference

1.9 SIG_TOWER_DELAY_TIMER
_WaitPanelOnDelayTimer 0 ~ 300 O
[Explanation] Sets the delay timer (sec) for waiting for a panel.
[Default] 0
_WaitNextMcOnDelayTimer 0 ~ 300 O
[Explanation] Sets the delay timer (sec) for waiting for signal from next machine.
[Default] 0
1.10 CYCLE_STEAL
_CycleStealStartTime O
[Explanation] Set the amount of time (in minutes) between cycle steal
measurements.[Default] 5
_CycleStealTerm O
[Explanation] Set the error tolerance for fiducial mark measurement when cycle steal
is carried out.
[Default] 10
_CycleStealDistanceLimit O
[Explanation] This is the tolerance for the difference between the distance obtained
during cycle steal from the center of the fiducial camera to the center of
rotation and the Proper data value [_Camera 1/2 Distance X/Y]. If this
difference exceeds the tolerance, an error stop occurs.
[Default] 100
1.11 AUTO_SETUP
_ASSMCNum –
[Explanation] Not used.
[Default] 0
_MCComPort –
[Explanation] Not used.
[Default] 10000
_PCComPort –
[Explanation] Not used.
[Default] 10000
_ASSFeederChk –
[Explanation] Not used.
[Default] 0
_ASSFeederChkAllSet –
[Explanation] Not used.
[Default] 0
_ASSetupInfoDisp –
[Explanation] Not used.
[Default] 0
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-16 XP-142E System Reference

1.12 DEBUG_FLAG
[Explanation] This section is for debugging.
_DebugFlag1 X
_DebugFlag2 X
_DebugFlag3 X
_DebugFlag4 X
_DebugFlag5 X
_DebugFlag6 X
_DebugFlag7 X
_DebugFlag8 X
_DebugFlag9 X
_DebugFlag10 X
_DebugBP X
_DebugDLL X
_DebugBML X
_DebugPartsCheck X
_CStructCheck XR
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-17 XP-142E System Reference