1. Error Code Messages and Corrective Measures (ESR0901) The following is a list of the error messages that appear with error codes. If an error message appears without a code (number), refer to Section 2, “Corrective Me…

Part 8
Errors and
Countermeasures
(ESR09AA)
This chapter provides a list of the
error codes that appear on the screen
when a machine error occurs, along
with measures that can be taken to
correct the error.
1. Error Code Messages and Corrective Measures
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-1-1
2. Corrective Measures for Error Messages that
Appear without an Error Code . . . . . . . . . .8-2-1
3. Corrective Measures for Problems at the
Machine
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-3-1

1. Error Code Messages and Corrective Measures
(ESR0901)
The following is a list of the error messages that appear with error codes.
If an error message appears without a code (number), refer to Section 2, “Corrective Measures
for Error Messages that Appear without an Error Code”.
All error codes are 8 characters in length (Ex. 1101B000, 1101B001)
The error codes are listed in ascending order of code number.
Code: 1101B000
Display: [***] is a range error.
Cause: A value which exceeds the permissible input range was entered.
Remedy: Enter a value within the permissible input range.
Code: 1101B001
Display: [***] is not defined.
Cause: If the set items are values, enter 0, if they are characters leave the fields blank.
Remedy: Input valid values.
Code: 1101C700
Display: Feeder skip settings of “0” and “1” have both been specified in the sequence data
for the same stage and slot number.
Cause: Sequence data with and without feeder skip settings exist for the same stage/slot
number.
Remedy: Correct the sequence data so that all sequences for the same stage/slot number
have the same feeder skip settings.
Code: 1101C701
Display: If a joint mode is not specified, stage 2 cannot be set in the sequence.
Cause: If a joint mode is not specified, stage 2 cannot be set in the sequence.
Remedy: Either skip all of the sequence data specified in stage 2, or delete stage 2.
Code: 1101C702
Display: Sequence Data (D) does not exist.
Cause: There is not a placement sequence in Sequence Data (Type D).
Remedy: When operating the machine without a placement sequence, set the pass mode in
panel data to “1: Pass”.
Code: 1101C703
Display: “Position X” exceeds the range of the panel.
Cause: The sequence data”s X-coordinate is off the panel.
Remedy: Specify an X-coordinate which is within the panel size range.
Code: 1101C704
Display: “Position Y” exceeds the range of the panel.
Cause: The sequence data”s Y-coordinate is off the panel.
Remedy: Specify an Y-coordinate which is within the panel size range.
Code: 1101C705
Display: There are sequences on the same board with the same mark number.
Cause: A fiducial mark reading sequence exists which has duplicate mark numbers
within a single board.
Remedy: Revise either the “Board No.” or “Mark No.” in the sequence data.
Part 8 Chapter 1 Error Codes and Corrective Measures
Edition 2.0 8-1-1 XP-142E System Reference

Part 8 Chapter 1 Error Code Messages and Corrective Measures
Edition 2.0 8-1-2 XP-142E System Reference
Code: 1101C706
Display: The main mark number is the same as the sub mark number.
Cause: The same setting value is specified for both the main mark number and the sub-
mark number in the part placement sequence.
Remedy: Specify setting values so that the main mark number and sub-mark number are
different.
Code: 1101C707
Display: Cannot locate the mark sequence for the mark No. specified at main mark No.
Cause: A fiducial mark reading sequence which contains the specified (in the part
placement sequence) main mark number cannot be found.
Remedy: Set the fiducial mark reading sequence for the specified main mark number to
occur before the part placement sequence.
Code: 1101C708
Display: Cannot locate the mark sequence for the mark No. specified at sub mark No.
Cause: A fiducial mark reading sequence which contains the specified (in the part
placement sequence) sub-mark number cannot be found.
Remedy: Set the fiducial mark reading sequence for the specified sub-mark number to occur
before the part placement sequence.
Code: 1101C709
Display: The stage number and slot number are not defined.
Cause: No setting data exists for the stage number and slot number specified in the
sequence data.
Remedy: Either specify settings for the stage number and slot number in the feeder setup
data, or specify a stage number and slot number for which setting data already
exists.
Code: 1101C70A
Display: Board skip settings of “0” and “1” have both been specified in the sequence data
for the same board.
Cause: Sequence data with and without board skip settings exist for the same board.
Remedy: Correct the sequence data so that all sequences for the same board have the same
board skip settings.
Code: 1101C70B
Display: The “Ref” (“Sequence Comment”) sequence specified for the “Place Before”
sequence does not exist on the same board.
Cause: The “Ref” (“Sequence Comment”) sequence specified for the “Place Before”
sequence does not exist on the same board.
Remedy: Specify a “Ref” (“Sequence Comment”) sequence that applies to the same board as
that of the “Place Before” sequence.
The “Place Before” sequence is ignored where the “Ref” (“Sequence Comment”)
sequence does not apply to the same board.
Code: 1101C70C
Display: The same name has been allocated to “Place Before” and “Ref” (“Sequence
Comment”).
Cause: The same name has been allocated to the “Place Before” and “Ref” (“Sequence
Comment”) sequences.
Remedy: Specify different names for the “Place Before” and “Ref” (“Sequence Comment”)
sequences.