XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第294页

Code: 1101D311 Display: [Packaging Type] - [Feed Count] must be set to 3 or less when [Packaging Type] - [Type] is set to 4 or 9. Cause: The stick feeder “FeedCount” is set to 4 or more. Remedy: When using the Stick Feed…

100%1 / 344
Code: 1101D307
Display: When using Vision Type 230 or 231, set the P Pattern to 1 or 2.
Cause: For Vision Types 230 and 231, vision processing is only possible when the
“P Pattern” is set to 1 or 2.
Remedy: For Vision Types 230 and 231, set the “P Pattern” to 1 or 2.
Code: 1101D308
Display: A setting of [128] exists at the first Result line for the Element item of a Vision
Type 230 or 231 part.
Cause: A setting of “128” exists at the first Result line for the Element item of a Vision
Type 230 or 231 part.
Remedy: Specify a setting other “128” at the first Result line for the Element item of a Vision
Type 230 or 231 part.
Code: 1101D30A
Display: A Lead Length setting of other than 0 is required for vision types 20, 100, 124 and
180.
Cause: A “Lead Length” setting of “0” exists at the ElementData item of the Part Data,
even though a Vision Type of 20, 100, 124 or 180 is specified.
Remedy: Specify a suitable “Lead Length” setting.
Code: 1101D30B
Display: A Lead Quantity setting of other than 0 is required for vision types 20, 100, 124,
130and 180.
Cause: A “Lead Quantity” setting of “0” exists at the ElementData item of the Part Data,
even though a Vision Type of 20, 100, 124, 130 or 180 is specified.
Remedy: Specify a suitable “Lead Quantity” setting.
Code: 1101D30C
Display: A Lead Width setting of other than 0 is required for vision types 20, 100, 124, 130
and 180.
Cause: A “Lead Width” setting of “0” exists at the ElementData item of the Part Data,
even though a Vision Type of 20, 100, 124, 130 or 180 is specified.
Remedy: Specify a suitable “Lead Width” setting.
Code: 1101D30D
Display: Specify Lead Pitch if the Lead Quantity is 2 or greater.
Cause: A “Lead Pitch” setting of “0” existed when the “Lead Quantity” setting was 2 or
more.
Remedy: When the “Lead Quantity” setting is 2 or more, specify a “Lead Pitch” setting.
Code: 1101D30E
Display: Vision Type 230, 231 cannot be used to process BGAs with less than 12 balls.
Cause: Vision Type 230 and 231 vision processing is not possible for BGA parts with
fewer than 12 balls.
Remedy: Set the Element”s “Lead Quantity” so that the total number of balls is 12 or more.
If the total number of balls is fewer than 12, use Vision Type 18.
Part 8 Chapter 1 Error Codes and Corrective Measures
Edition 2.0 8-1-5 XP-142E System Reference
Code: 1101D311
Display: [Packaging Type] - [Feed Count] must be set to 3 or less when [Packaging Type]
- [Type] is set to 4 or 9.
Cause: The stick feeder “FeedCount” is set to 4 or more.
Remedy: When using the Stick Feeder and Grooved Stick Feeder packaging types, specify a
“FeedCount” setting of 3 or less.
Code: 1101D312
Display: The pick up point for the last tray parts exceeds the tray size in the X-direction.
Cause: The pick up point for the last tray parts exceeds the tray size in the X-direction.
Remedy: Specify a setting value which satisfies the following equation.
[Tray Length] { [Tray First Pickup Position X] x (-1) } + { [Tray Column Pitch] x
( [Tray Column Quantity] - 1) }
Code: 1101D313
Display: The pick up point for the last tray parts exceeds the tray size in the Y-direction.
Cause: The final pickup position for tray parts exceeds the tray”s Y-direction size.
Remedy: Specify a setting value which satisfies the following equation.
[Tray Width] [Tray First Pickup Position Y] + [Tray Row Pitch] x ( [Tray Row
Quantity] - 1 )
Code: 1101D314
Display: Tray Length is incorrect. Tray is not able to be ejected.
Cause: The length of the tray to be unloaded (Tray Type 0 or 2) is set as smaller than the
remover.
Remedy: Specify a “Tray Length” setting of 72 or higher.
Code: 1101D315
Display: Tray Width is incorrect. Tray is not able to be eject.
Cause: The width of the tray to be unloaded (Tray Type 0 or 2) is set as smaller than the
remover.
Remedy: Specify a “Tray Width” setting of 83 or higher.
Code: 1101D316
Display: Tray Dump Pick Position X is incorrect. Tray is not able to be eject.
Cause: The remover (nozzle used to unload trays) protrudes beyond the tray in the X-
direction when picking up a tray.
Remedy: Specify the “Tray Dump Pick Position X” setting so that the remover does not
protrude beyond the tray in the X-direction when picking up trays.
Code: 1101D317
Display: Tray Dump Pick Position Y is incorrect. Tray is not able to be eject.
Cause: The remover (nozzle used to unload trays) protrudes beyond the tray in the Y-
direction when picking up trays.
Remedy: Specify the “Tray Dump Pick Position Y” setting so that the remover does not
protrude beyond the tray in the Y-direction when picking up trays.
Code: 1101D318
Display: No template file.
Cause: Cannot locate a template file that matches the part type name of the part data for
Vision type 18.
Remedy: Prepare a template file that has a file name that matches the part type name.
Part 8 Chapter 1 Error Code Messages and Corrective Measures
Edition 2.0 8-1-6 XP-142E System Reference
Code: 1101D319
Display: No matching nozzle.
Cause: The nozzle data contains neither the nozzle specified by the NozzleName item (in
Part Type data), or a nozzle which satisfies the NozzleSizeMin to NozzleSizeMax
range setting.
Remedy: Specify the appropriate nozzle in the nozzle data.
Code: 1101D31A
Display: When using Vision Type 100 or 130, the Lead Quantity must be 5 or greater for the
first element.
Cause: When using Vision Type 100 or 130, the “Element” first line “Lead Quantity” was
less than 5.
Remedy: When using Vision Types 100 and 130, specify the “Element” first line “Lead
Quantity” as 5 or more.
Code: 1101D31B
Display: Tray cannot be removed. Input the tray thickness (4.00 mm - 25.40 mm).
Cause: The tray dimensions are outside the permissible XP tray specifications
(4.00 mm - 25.40 mm).
Remedy: Input a permissible tray thickness (4.00 mm - 25.40 mm).
Code: 1101D31C
Display: The nozzle interferes with the tray positioning plate when picking up parts.
(At the front side of the tray as seen from the front of the machine.)
Cause: The nozzle interferes with the tray positioning plate when picking up parts.
(At the front side of the tray as seen from the front of the machine.)
Remedy: Change the [Tray First Pickup Position Y] setting in the part data, or change one of
the following settings (as applicable) so that nozzles do not interfere with the tray
positioning plate.
*If [Direction] is set to 1 or 3, change the [Pick-up Point Offset X] setting.
*If [Direction] is set to 0 or 2, change the [Pick-up Point Offset Y] setting.
Code: 1101D31D
Display: The nozzle interferes with the tray positioning plate when picking up parts.
(The right side of the tray as seen from the front of the machine.)
Cause: The nozzle interferes with the tray positioning plate when picking up parts.
(The right side of the tray as seen from the front of the machine.)
Remedy: Change the [Tray First Pickup Position X] setting in the part data, or change one of
the following settings (as applicable) so that nozzles do not interfere with the tray
positioning plate.
*If [Direction] is set to 0 or 2, change the [Pick-up Point Offset X] setting.
*If [Direction] is set to 1 or 3, change the [Pick-up Point Offset Y] setting.
Code: 1101D31E
Display: The nozzle interferes with the tray positioning plate when picking up parts.
(The left side of the tray as seen from the front of the machine.)
Cause: The nozzle interferes with the tray positioning plate when picking up parts.
(The left side of the tray as seen from the front of the machine.)
Remedy: Change the [Tray First Pickup Position X] setting in the part data, or change one of
the following settings (as applicable) so that nozzles do not interfere with the tray
positioning plate.
*If [Direction] is set to 0 or 2, change the [Pick-up Point Offset X] setting.
*If [Direction] is set to 1 or 3, change the [Pick-up Point Offset Y] setting.
Part 8 Chapter 1 Error Codes and Corrective Measures
Edition 2.0 8-1-7 XP-142E System Reference