XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第298页
Code: 1101D331 Display: Feed pitch is incorrect. The current feed pitch of ** was extrapolated from the packaging name data. Cause: The feed pitch is incorrect. The current feed pitch was extrapolated from the packaging …

Code: 1101D32A
Display: The part size or Scan Area X, Scan Area Y setting exceeds the scanning range that
can be handled by the camera.
Cause: The part size or Scan Area X, Scan Area Y setting exceeds the scanning range that
can be handled by the camera.
Remedy: Specify a part size or Scan Area X, Scan Area Y setting value that is within the
scanning range that can be handled by the camera.
With the Pick-up Point Offset X and Pick-up Point Offset Y settings taken into
account, the maximum part size that may be specified is 20 mm x 20 mm, and the
maximum scan area is 25 mm x 24 mm,
Code: 1101D32B
Display: A nozzle that matches nozzle no. ** cannot be found.
Cause: A nozzle that matches nozzle no. ** cannot be found.
Remedy: Specify a matching nozzle in the nozzle data.
Code: 1101D32C
Display: The part cannot be picked up because it interferes with an adjacent nozzle.
Cause: The part cannot be picked up because it interferes with an adjacent nozzle.
Remedy: Change the nozzle configuration.
Code: 1101D32D
Display: The part will not be picked up at its center so as to prevent part interference (Y-
offset amount: *.* mm).
Cause: The part will not be picked up at its center, as the offset function is in use for
automatic interference prevention.
Remedy: To specify pick-up at the part center, set Pick-up Point Offset Y to 0.1, or set Scan
Area Y to 23 or less.
Code: 1101D32E
Display: There is a possibility of interference with nozzle no. **.
Cause: A corner of the part may interfere with nozzle no. **.
Remedy: Check the part shape, and if there is a possibility of interference, change either the
nozzle size or nozzle position.
Code: 1101D32F
Display: 5 or more leads do not exist, or the part exceeds the scan range that can be handled
by the camera.
Cause: 5 or more leads are required. Where 5 or more leads exist, and the part is picked
up at the revolver center, the part exceeds the scan range that can be handled by
the camera.
Remedy: Create the part data using vision type 18 or 20.
Code: 1101D330
Display: No template data exists.
Cause: Template data is required for Vision Type 18 in part data.
Remedy: If the error occurred even though template file reading using
_CCIMFTemplateMode in Proper data is specified, then create template data.
When using an existing template file, specify that the template file is read.
Part 8 Chapter 1 Error Codes and Corrective Measures
Edition 2.0 8-1-9 XP-142E System Reference

Code: 1101D331
Display: Feed pitch is incorrect. The current feed pitch of ** was extrapolated from the
packaging name data.
Cause: The feed pitch is incorrect. The current feed pitch was extrapolated from the
packaging name data.
Remedy: If there is a problem with the extrapolated feed pitch, then specify the correct feed
pitch.
Code: 1101D332
Display: Feed pitch is incorrect. The current feed pitch is 2.
Cause: Feed pitch is incorrect. The current feed pitch is 2.
Remedy: If there is a problem with feed pitch of 2, then specify the correct feed pitch.
Code: 1101D333
Display: When performing the template command for a Vision Type other than 18, specify
Body Length (X) and Body Width (Y).
Cause: When performing the template command for a Vision Type other than 18, specify
Body Length (X) and Body Width (Y).
Remedy: Specify body length (X) and body width (Y), or change the vision type to 18.
Code: 1101D334
Display: The part size, Scan Area X, or Scan Area Y exceeds the vision processing range for
Front Sidelight (20 x 20).
Cause: The part size, Scan Area X, or Scan Area Y exceeds the vision processing range for
Front Sidelight (20 x 20).
Remedy: Specify camera position “0: Auto” or “2: Rear”.
Code: 1101D335
Display: When setting the Scan Area, set both Scan Area X and Scan Area Y at the same
time.
Cause: Only Scan Area X or Scan Area Y is set.
Remedy: When setting the Scan Area, set both Scan Area X and Scan Area Y at the same
time.
Code: 1101D3F0
Display: Compile error.
Cause: Vision processing Data Error
Remedy: Cannot read the part data.
Either the part data format or the part data is incorrect.
Revise the applicable part data.
Also, if the part data is administered over a network, check the network.
Code: 1101D3F1
Display: Compile error.
Cause: Vision processing Data Error
Remedy: Cannot read the part data.
Either the part data format or the part data is incorrect.
Revise the applicable part data.
Also, if the part data is administered over a network, check the network.
Part 8 Chapter 1 Error Code Messages and Corrective Measures
Edition 2.0 8-1-10 XP-142E System Reference

Code: 1101D3F2
Display: Compile error.
Cause: Vision processing Data Error
Remedy: Cannot read the part data.
Either the part data format or the part data is incorrect.
Revise the applicable part data.
Also, if the part data is administered over a network, check the network.
Code: 1101D3F3
Display: Compile error.
Cause: Vision processing Data Error
Remedy: Cannot read the part data.
Either the part data format or the part data is incorrect.
Revise the applicable part data.
Also, if the part data is administered over a network, check the network.
Code: 1101D3F4
Display: Compile error.
Cause: Vision processing Data Error
Remedy: Cannot read the part data.
Either the part data format or the part data is incorrect.
Revise the applicable part data.
Also, if the part data is administered over a network, check the network.
Code: 1101D3F5
Display: Compile error.
Cause: Vision processing Data Error
Remedy: Cannot read the part data.
Either the part data format or the part data is incorrect.
Revise the applicable part data.
Also, if the part data is administered over a network, check the network.
Code: 1101D3F6
Display: Compile error.
Cause: Vision processing Data Error
Remedy: Cannot read the part data.
Either the part data format or the part data is incorrect.
Revise the applicable part data.
Also, if the part data is administered over a network, check the network.
Code: 1101E300
Display: fiducial mark is not defined.
Cause: There is no fiducial mark setting in the production program.
Remedy: Specify a fiducial mark setting at the Edit Mark screen.
Code: 1101E301
Display: Board Skip Mark is not defined.
Cause: A board skip mark reading sequence exists, but there is no board skip mark
setting.
Remedy: Specify a board skip mark setting at the Edit Mark screen.
Part 8 Chapter 1 Error Codes and Corrective Measures
Edition 2.0 8-1-11 XP-142E System Reference