1.8 CAMERA_UNIT _Camera0UnitX X [Explanation] Sets the camera no. 0 unit value X. [Default] Proper data measurement result. _Camera0UnitY X [Explanation] Sets the camera no. 0 unit value Y. [Default] Proper data measurem…

100%1 / 344
1.7 Machine_TYPE_2
_MachineParameter1
[Explanation] Not used.
[Default] 0
_StageModeSW 0:1:2 XR
[Explanation] Stage mode (AA mode) function setting.
0: Standard machines
1, 2: Standard stage change mode machines
[Default] 0
_RemoverType
[Explanation] Not used.
[Default] 0
_FiducailLampType
[Explanation] Not used.
[Default] 0
_TrayRetractCheck
[Explanation] Not used.
[Default] 0
_TrayUnitType
[Explanation] Not used.
[Default] 0
_UseMicroTray
[Explanation] Not used.
[Default] 0
_SetDetectSensorSW 0:1 XR
[Explanation] Set whether the tape leaf sensor is used or not.
0: Unsupported
1: Tape leaf W sensor.
[Default] 0
_EjectPanelUncondtion 0:1:2 O
[Explanation] Set the machine action for when, during panel eject, the panel request
signal from the next machine is terminated while the panel is passing
the MAIN or OUT pass sensor.
0: Default
1: Continue eject panel processing
2: Force eject panel to next machine
[Default] 0
_VerifierTool 0:1 O
[Explanation] Sets hardware used by parts verifier
0: Do not use
1: Wireless barcode reader (local verifier)
[Default] 0
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-14 XP-142E System Reference
1.8 CAMERA_UNIT
_Camera0UnitX X
[Explanation] Sets the camera no. 0 unit value X.
[Default] Proper data measurement result.
_Camera0UnitY X
[Explanation] Sets the camera no. 0 unit value Y.
[Default] Proper data measurement result.
_Camera1UnitX X
[Explanation] Sets the camera no. 1 unit value X.
[Default] Proper data measurement result.
_Camera1UnitY X
[Explanation] Sets the camera no. 1 unit value Y.
[Default] Proper data measurement result.
_Camera1UnitX_Low X
[Explanation] Sets the camera no. 1 unit low poisition value X.
[Default] Proper data measurement result.
_Camera1UnitY_Low X
[Explanation] Sets the camera no. 1 unit low position value Y.
[Default] Proper data measurement result.
_Camera2UnitX X
[Explanation] Sets the camera no. 2 unit value X.
[Default] Proper data measurement result.
_Camera2UnitY X
[Explanation] Sets the camera no. 2 unit value Y.
[Default] Proper data measurement result.
_Camera3UnitX X
[Explanation] Sets the camera no. 3 unit value X.
[Default] Proper data measurement result.
_Camera3UnitY X
[Explanation] Sets the camera no. 3 unit value Y.
[Default] Proper data measurement result.
_Camera4UnitX X
[Explanation] Sets the camera no. 4 unit value X.
[Default] Proper data measurement result.
_Camera4UnitY X
[Explanation] Sets the camera no. 4 unit value Y.
[Default] Proper data measurement result.
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-15 XP-142E System Reference
1.9 SIG_TOWER_DELAY_TIMER
_WaitPanelOnDelayTimer 0 ~ 300 O
[Explanation] Sets the delay timer (sec) for waiting for a panel.
[Default] 0
_WaitNextMcOnDelayTimer 0 ~ 300 O
[Explanation] Sets the delay timer (sec) for waiting for signal from next machine.
[Default] 0
1.10 CYCLE_STEAL
_CycleStealStartTime O
[Explanation] Set the amount of time (in minutes) between cycle steal
measurements.[Default] 5
_CycleStealTerm O
[Explanation] Set the error tolerance for fiducial mark measurement when cycle steal
is carried out.
[Default] 10
_CycleStealDistanceLimit O
[Explanation] This is the tolerance for the difference between the distance obtained
during cycle steal from the center of the fiducial camera to the center of
rotation and the Proper data value [_Camera 1/2 Distance X/Y]. If this
difference exceeds the tolerance, an error stop occurs.
[Default] 100
1.11 AUTO_SETUP
_ASSMCNum
[Explanation] Not used.
[Default] 0
_MCComPort
[Explanation] Not used.
[Default] 10000
_PCComPort
[Explanation] Not used.
[Default] 10000
_ASSFeederChk
[Explanation] Not used.
[Default] 0
_ASSFeederChkAllSet
[Explanation] Not used.
[Default] 0
_ASSetupInfoDisp
[Explanation] Not used.
[Default] 0
Part 6 Chapter 1 Proper Data Measurement