Q_StbTimeFast X [Explanation] Sets the time (msec) for the Q-axis to stabilize when in fast mode. [Default] Proper data measurement result. X_StbTimeSlow X [Explanation] Sets the time (msec) for the X-axis to stabilize w…

1.3 SERVO_OFST
_targetOfst_X XR
[Explanation] Absolute encoder offset (mm).
[Default] Proper data measurement result.
_targetOfst_Y XR
[Explanation] Absolute encoder offset (mm).
[Default] Proper data measurement result.
_targetOfst_Z XR
[Explanation] Absolute encoder offset (mm).
[Default] Proper data measurement result.
_targetOfst_Q XR
[Explanation] Absolute encoder offset (mm).
[Default] Proper data measurement result.
_targetOfst_R XR
[Explanation] Absolute encoder offset (mm).
[Default] Proper data measurement result.
_targetOfst_T –
[Explanation] Not used.
[Default] 0
_targetOfst_U –
[Explanation] Not used.
[Default] 0
_targetOfst_F XR
[Explanation] Absolute encoder offset (mm).
[Default] Proper data measurement result.
_targetOfst_G XR
[Explanation] Absolute encoder offset (mm).
[Default] Proper data measurement result.
_TestOption –
[Explanation] Not used.
[Default] 0
X_StbTimeFast X
[Explanation] Sets the time (msec) for the X-axis to stabilize when in fast mode.
[Default] Proper data measurement result.
Y_StbTimeFast X
[Explanation] Sets the time (msec) for the Y-axis to stabilize when in fast mode.
[Default] Proper data measurement result.
R_StbTimeFast X
[Explanation] Sets the time (msec) for the R-axis to stabilize when in fast mode.
[Default] Proper data measurement result.
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-7 XP-142E System Reference

Q_StbTimeFast X
[Explanation] Sets the time (msec) for the Q-axis to stabilize when in fast mode.
[Default] Proper data measurement result.
X_StbTimeSlow X
[Explanation] Sets the time (msec) for the X-axis to stabilize when in slow mode.
[Default] Proper data measurement result.
Y_StbTimeSlow X
[Explanation] Sets the time (msec) for the Y-axis to stabilize when in slow mode.
[Default] Proper data measurement result.
R_StbTimeSlow X
[Explanation] Sets the time (msec) for the R-axis to stabilize when in slow mode.
[Default] Proper data measurement result.
Q_StbTimeSlow X
[Explanation] Sets the time (msec) for theQ-axis to stabilize when in slow mode.
[Default] Proper data measurement result.
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-8 XP-142E System Reference

1.4 OPERATION_2
_DoNozzleCleaning 0:1 O
[Explanation] Set whether nozzle cleaning is used or not.
0: Not used
1: Used
[Default] 1
_PolarityConvert 0:1 OR
[Explanation] Specifies the polarity converter start.
0: Start
1: Do not start
Note: Do not set to “0”.
[Default] 1
_DChangeTriger 0:1:2:3 O
[Explanation] Specifies the slot / stage change trigger.
0: Move to the next slot after a parts out or vision processing error.
1, 2: Move to the next slot after a parts out error. Machine stops if
vision processing error occurs.
3: Refers to the Alt. Feeder Trigger setting in part data, to move to
the next slot or stop the machine.
[Default] 0
_ResetNGPartTrayUncondition 0:1 O
[Explanation] Specifies whether or not to confirm opening and closing of the door
after the NG part tray fills up.
0: Confirm
1: Do not confirm
[Default] 0
_NotSimpleOptimize –
[Explanation] Not used.
[Default] 0
_NozzleSufrfaceCheck 0:1 O
[Explanation] Enables/disables the function which checks for foreign matter
adhering to nozzles.
0: Not used
1: Used
[Default] 0
_UseVisionHeightOffset –
[Explanation] Not used.
[Default] 0
_FrontSideShtSpd –
[Explanation] Not used.
[Default] 0
_FrontFrontShtSpd –
[Explanation] Not used.
[Default] 0
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-9 XP-142E System Reference