XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第293页
Code: 1101D307 Display: When using Vision Type 230 or 231, set the P Pattern to 1 or 2. Cause: For Vision Types 230 and 231, vision processing is only possible when the “P Pattern” is set to 1 or 2. Remedy: For Vision Ty…

Code: 1101D206
Display: The Alt. Feeder does not form a loop.
Cause: The next slot number does not have a loop structure.
Remedy: Set the next slot number so that a loop structure is created.
Code: 1101D207
Display: An unavailable stage is set in the feeder setup data.
Cause: Stage 2 is set in the feeder setup data for the single side parts supplying machine.
Remedy: Either delete the stage 2 feeder data, or move them to stage 1.
Code: 1101D300
Display: The Polarity Setting item”s [Not Use] setting is not supported.
Cause: XP-series machines do not support Polarity Setting”s “Not Use” setting. (Except
for program data transmitted from MCS/2.)
Remedy: Set the Polarity Setting to another setting.
Code: 1101D301
Display: The “Not Use” setting for the “Polarity Setting” item is not supported for MCS/2
programs received by XP-1-series machines.
Cause: MCS/2 programs received by XP-1-series machines with the “Polarity Setting”
item set to “Not Use” may only be used on XP-1-series machines.
Remedy: Set the “Polarity Setting” item to a setting other than “Not Use”.
Code: 1101D302
Display: The “Not Use” setting for the “Polarity Setting” item is not supported for MCS/2
programs received by XP-2 / XP-3-series machines.
Cause: MCS/2 programs received by XP-2 / XP-3-series machines with the “Polarity
Setting” item set to “Not Use” may only be used on XP-2 / XP-3-series machines.
Remedy: Set the “Polarity Setting” item to a setting other than “Not Use”.
Code: 1101D303
Display: The element data is required when the vision type is other than 10 or 18.
Cause: There is no ElementData although a Vision Type other than 10 or 18 is specified.
Remedy: Set the ElementData.
Code: 1101D305
Display: The settings at Scan Area X and Scan Area Y are outside the range that can be
handled by the Front (Rear) camera (short side: **.***; long side: **.***).
Cause: The settings at “Scan Area X” and “Scan Area Y” are outside the range that can be
handled by the Front (Rear) camera.
Remedy: Compare “Scan Area X” with “Scan Area Y.” The one with the lower value should
be set to be shorter than the short side of the field of view, and the one with the
higher value should be set to be shorter than the long side.
Code: 1101D306
Display: A setting of [128] exists at two consecutive Result lines for the Element item of a
Vision Type 230 or 231 part.
Cause: A setting of “128” exists at two consecutive Result lines for the Element item of a
Vision Type 230 or 231 part.
Remedy: Do not specify a “128” setting at two consecutive Result lines for the Element item
of a Vision Type 230 or 231 part.
Part 8 Chapter 1 Error Code Messages and Corrective Measures
Edition 2.0 8-1-4 XP-142E System Reference

Code: 1101D307
Display: When using Vision Type 230 or 231, set the P Pattern to 1 or 2.
Cause: For Vision Types 230 and 231, vision processing is only possible when the
“P Pattern” is set to 1 or 2.
Remedy: For Vision Types 230 and 231, set the “P Pattern” to 1 or 2.
Code: 1101D308
Display: A setting of [128] exists at the first Result line for the Element item of a Vision
Type 230 or 231 part.
Cause: A setting of “128” exists at the first Result line for the Element item of a Vision
Type 230 or 231 part.
Remedy: Specify a setting other “128” at the first Result line for the Element item of a Vision
Type 230 or 231 part.
Code: 1101D30A
Display: A Lead Length setting of other than 0 is required for vision types 20, 100, 124 and
180.
Cause: A “Lead Length” setting of “0” exists at the ElementData item of the Part Data,
even though a Vision Type of 20, 100, 124 or 180 is specified.
Remedy: Specify a suitable “Lead Length” setting.
Code: 1101D30B
Display: A Lead Quantity setting of other than 0 is required for vision types 20, 100, 124,
130and 180.
Cause: A “Lead Quantity” setting of “0” exists at the ElementData item of the Part Data,
even though a Vision Type of 20, 100, 124, 130 or 180 is specified.
Remedy: Specify a suitable “Lead Quantity” setting.
Code: 1101D30C
Display: A Lead Width setting of other than 0 is required for vision types 20, 100, 124, 130
and 180.
Cause: A “Lead Width” setting of “0” exists at the ElementData item of the Part Data,
even though a Vision Type of 20, 100, 124, 130 or 180 is specified.
Remedy: Specify a suitable “Lead Width” setting.
Code: 1101D30D
Display: Specify Lead Pitch if the Lead Quantity is 2 or greater.
Cause: A “Lead Pitch” setting of “0” existed when the “Lead Quantity” setting was 2 or
more.
Remedy: When the “Lead Quantity” setting is 2 or more, specify a “Lead Pitch” setting.
Code: 1101D30E
Display: Vision Type 230, 231 cannot be used to process BGAs with less than 12 balls.
Cause: Vision Type 230 and 231 vision processing is not possible for BGA parts with
fewer than 12 balls.
Remedy: Set the Element”s “Lead Quantity” so that the total number of balls is 12 or more.
If the total number of balls is fewer than 12, use Vision Type 18.
Part 8 Chapter 1 Error Codes and Corrective Measures
Edition 2.0 8-1-5 XP-142E System Reference

Code: 1101D311
Display: [Packaging Type] - [Feed Count] must be set to 3 or less when [Packaging Type]
- [Type] is set to 4 or 9.
Cause: The stick feeder “FeedCount” is set to 4 or more.
Remedy: When using the Stick Feeder and Grooved Stick Feeder packaging types, specify a
“FeedCount” setting of 3 or less.
Code: 1101D312
Display: The pick up point for the last tray parts exceeds the tray size in the X-direction.
Cause: The pick up point for the last tray parts exceeds the tray size in the X-direction.
Remedy: Specify a setting value which satisfies the following equation.
[Tray Length] ≥ { [Tray First Pickup Position X] x (-1) } + { [Tray Column Pitch] x
( [Tray Column Quantity] - 1) }
Code: 1101D313
Display: The pick up point for the last tray parts exceeds the tray size in the Y-direction.
Cause: The final pickup position for tray parts exceeds the tray”s Y-direction size.
Remedy: Specify a setting value which satisfies the following equation.
[Tray Width] ≥ [Tray First Pickup Position Y] + [Tray Row Pitch] x ( [Tray Row
Quantity] - 1 )
Code: 1101D314
Display: Tray Length is incorrect. Tray is not able to be ejected.
Cause: The length of the tray to be unloaded (Tray Type 0 or 2) is set as smaller than the
remover.
Remedy: Specify a “Tray Length” setting of 72 or higher.
Code: 1101D315
Display: Tray Width is incorrect. Tray is not able to be eject.
Cause: The width of the tray to be unloaded (Tray Type 0 or 2) is set as smaller than the
remover.
Remedy: Specify a “Tray Width” setting of 83 or higher.
Code: 1101D316
Display: Tray Dump Pick Position X is incorrect. Tray is not able to be eject.
Cause: The remover (nozzle used to unload trays) protrudes beyond the tray in the X-
direction when picking up a tray.
Remedy: Specify the “Tray Dump Pick Position X” setting so that the remover does not
protrude beyond the tray in the X-direction when picking up trays.
Code: 1101D317
Display: Tray Dump Pick Position Y is incorrect. Tray is not able to be eject.
Cause: The remover (nozzle used to unload trays) protrudes beyond the tray in the Y-
direction when picking up trays.
Remedy: Specify the “Tray Dump Pick Position Y” setting so that the remover does not
protrude beyond the tray in the Y-direction when picking up trays.
Code: 1101D318
Display: No template file.
Cause: Cannot locate a template file that matches the part type name of the part data for
Vision type 18.
Remedy: Prepare a template file that has a file name that matches the part type name.
Part 8 Chapter 1 Error Code Messages and Corrective Measures
Edition 2.0 8-1-6 XP-142E System Reference