XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第237页
_ErrStopBeforeFid 0:1 O [Explanation] Set whether the machine is stopped before fiducial marks are read, if an inspection error occurs for parts picked in advance. 0: The machine is not stopped. 1: The machine is stopped…

_RearSideShtSpd –
[Explanation] Not used.
[Default] 0
_RearFrontShtSpd –
[Explanation] Not used.
[Default] 0
_PlacingModeSwitch 0 ~ 2 O
[Explanation] Set the double motion changeover at the placement.
0: Single motion
1: Double motion (Fine Slow & Fine Fast)
2: Double motion (All)
[Default] 0
_JogInterlockOFF 0:1 X
[Explanation] Set whether the jog interlock is used or not.
0: Enabled
1: Disabled
[Default] 0
_PickPosAutoMeasure 0:1:2 O
[Explanation] Set whether automatic placement position measurement is used or not.
0: Disabled
1: Placement position measurement is executed using the commands at
the screen.
2: Placement position measurement is executed automatically during
production, or using the commands at the screen.
[Default] 0
_UseMachineNozzleOnly 0:1 O
[Explanation] Set whether the nozzles loaded on the machine are used in the data
check carried out during operation preparations.
0: Not used
1: Used
[Default] 0
_MiniSigWhiteLighting 0:1 O
[Explanation] Specifies the lighting conditions for the operation display.
0: XP original
1: Fuji standard
[Default] 0
_VcmBreakChkSensor –
[Explanation] Not used.
[Default] 0
_NzlSizeChkFlag –
[Explanation] Not used.
[Default] 0
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-10 XP-142E System Reference

_ErrStopBeforeFid 0:1 O
[Explanation] Set whether the machine is stopped before fiducial marks are read, if
an inspection error occurs for parts picked in advance.
0: The machine is not stopped.
1: The machine is stopped.
[Default] 0
_MarkEditWndAutoOpen 0:1 O
[Explanation] Set whether the mark editing screen displays automatically if a fiducial
mark reading error occurs.
0: The screen is not displayed automatically.
1: The screen is displayed automatically.
[Default] 1
_OperationPanelDisp 0:1 O
[Explanation] Set whether operation panel switching is enabled during automatic
operation.
0: Disabled
1: Enabled
[Default] 0
_AutoConvWidth 0:1 O
[Explanation] Enables the conveyor width change function at the start of automatic
operation.
0: OFF
1: ON
[Default] 0
_PlaceUpDelayTimer –
[Explanation] Not used.
[Default] 0
_DisposePosAutoSW 0:1 O
[Explanation] Specifies automatic sorting of NG parts (to the box and tray).
0: Refers to the part data setting
1: Automatic sorting
[Default] 0
_NotFeederPrecedenceAction –
[Explanation] Not used.
[Default] 0
_FMarkReadBeforePickUp 0:1 O
[Explanation] Setting for performing pick-up in advance, while reading fiducial
marks
0: Advance pick-up
1: No advance pick-up
[Default] 0
_LoggingPort 0, 8000 ~ 8999 O
[Explanation] Specifies the UDP communication port number for the production
information log.
[Default] 0
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-11 XP-142E System Reference

_CCIMFTemplateMode 0:1 O
[Explanation] Setting for responding when template data is not found in the
production program (recipe) and vision type 18 is specified in part
data. Either an error occurs during data check, or the template data is
retrieved from the template file (.TPL).
0: Error
1: Retrieve from template file
[Default] 0
_BrightCheckErrorMode 0:1 O
[Explanation] Specifies whether or not to terminate production when a nozzle
brightness measurement error occurs..
0: Error stop
1: Error pass
[Default] 0
1.5 VISION
_FiducialMarkImperfect 0:1 OR
[Explanation] Set whether partial circle fiducial marks are supported or not.
0: Not supported
1: Supported
[Default] 0
_FiducialMeasureFailRatio 0 ~ 100 O
[Explanation] In order to enable the measure seek line failure ratio (%) setting, the
program must be reread and compiled.
[Default] 0
_BoardSkipMarkBrightnessLevel 0~ 255 O
[Explanation] Set the brightness level reading board skip marks. Values from 1 to
255 are valid. If a value of 0 or lower, or 256 or higher is specified, the
default value of 128 will be used.
[Default] 0
_LookUpTableOff 0:1 O
[Explanation] Specifies whether or not the machine performs image contrast offset
using the [Gain of Contrast Offset] value from part data.
[Default] 0: Used
1: Not used
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-12 XP-142E System Reference