_RearSideShtSpd – [Explanation] Not used. [Default] 0 _RearFrontShtSpd – [Explanation] Not used. [Default] 0 _PlacingModeSwitch 0 ~ 2 O [Explanation] Set the double motion changeover at the placement. 0: Single motion 1:…

100%1 / 344
1.4 OPERATION_2
_DoNozzleCleaning 0:1 O
[Explanation] Set whether nozzle cleaning is used or not.
0: Not used
1: Used
[Default] 1
_PolarityConvert 0:1 OR
[Explanation] Specifies the polarity converter start.
0: Start
1: Do not start
Note: Do not set to “0”.
[Default] 1
_DChangeTriger 0:1:2:3 O
[Explanation] Specifies the slot / stage change trigger.
0: Move to the next slot after a parts out or vision processing error.
1, 2: Move to the next slot after a parts out error. Machine stops if
vision processing error occurs.
3: Refers to the Alt. Feeder Trigger setting in part data, to move to
the next slot or stop the machine.
[Default] 0
_ResetNGPartTrayUncondition 0:1 O
[Explanation] Specifies whether or not to confirm opening and closing of the door
after the NG part tray fills up.
0: Confirm
1: Do not confirm
[Default] 0
_NotSimpleOptimize
[Explanation] Not used.
[Default] 0
_NozzleSufrfaceCheck 0:1 O
[Explanation] Enables/disables the function which checks for foreign matter
adhering to nozzles.
0: Not used
1: Used
[Default] 0
_UseVisionHeightOffset
[Explanation] Not used.
[Default] 0
_FrontSideShtSpd
[Explanation] Not used.
[Default] 0
_FrontFrontShtSpd
[Explanation] Not used.
[Default] 0
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-9 XP-142E System Reference
_RearSideShtSpd
[Explanation] Not used.
[Default] 0
_RearFrontShtSpd
[Explanation] Not used.
[Default] 0
_PlacingModeSwitch 0 ~ 2 O
[Explanation] Set the double motion changeover at the placement.
0: Single motion
1: Double motion (Fine Slow & Fine Fast)
2: Double motion (All)
[Default] 0
_JogInterlockOFF 0:1 X
[Explanation] Set whether the jog interlock is used or not.
0: Enabled
1: Disabled
[Default] 0
_PickPosAutoMeasure 0:1:2 O
[Explanation] Set whether automatic placement position measurement is used or not.
0: Disabled
1: Placement position measurement is executed using the commands at
the screen.
2: Placement position measurement is executed automatically during
production, or using the commands at the screen.
[Default] 0
_UseMachineNozzleOnly 0:1 O
[Explanation] Set whether the nozzles loaded on the machine are used in the data
check carried out during operation preparations.
0: Not used
1: Used
[Default] 0
_MiniSigWhiteLighting 0:1 O
[Explanation] Specifies the lighting conditions for the operation display.
0: XP original
1: Fuji standard
[Default] 0
_VcmBreakChkSensor
[Explanation] Not used.
[Default] 0
_NzlSizeChkFlag
[Explanation] Not used.
[Default] 0
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-10 XP-142E System Reference
_ErrStopBeforeFid 0:1 O
[Explanation] Set whether the machine is stopped before fiducial marks are read, if
an inspection error occurs for parts picked in advance.
0: The machine is not stopped.
1: The machine is stopped.
[Default] 0
_MarkEditWndAutoOpen 0:1 O
[Explanation] Set whether the mark editing screen displays automatically if a fiducial
mark reading error occurs.
0: The screen is not displayed automatically.
1: The screen is displayed automatically.
[Default] 1
_OperationPanelDisp 0:1 O
[Explanation] Set whether operation panel switching is enabled during automatic
operation.
0: Disabled
1: Enabled
[Default] 0
_AutoConvWidth 0:1 O
[Explanation] Enables the conveyor width change function at the start of automatic
operation.
0: OFF
1: ON
[Default] 0
_PlaceUpDelayTimer
[Explanation] Not used.
[Default] 0
_DisposePosAutoSW 0:1 O
[Explanation] Specifies automatic sorting of NG parts (to the box and tray).
0: Refers to the part data setting
1: Automatic sorting
[Default] 0
_NotFeederPrecedenceAction
[Explanation] Not used.
[Default] 0
_FMarkReadBeforePickUp 0:1 O
[Explanation] Setting for performing pick-up in advance, while reading fiducial
marks
0: Advance pick-up
1: No advance pick-up
[Default] 0
_LoggingPort 0, 8000 ~ 8999 O
[Explanation] Specifies the UDP communication port number for the production
information log.
[Default] 0
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-11 XP-142E System Reference