XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第283页

Part 7 I/O Map (ESR05AA) This part contains a list of the input signals from sensors and switches etc., and the output signals to actuators. (Press [Maintenance] - [I/O Check A] from the [Main] screen.) 1. System Input S…

100%1 / 344
1.36 COMMUNICATION
_PCIpAdr O
[Explanation] Network IP address of personal computer used as a FTP server.
[Default] None
_PCUserName O
[Explanation] User name specified at FTP server.
[Default] None
_PCPassword O
[Explanation] Password specified at FTP server.
[Default] None
_MC01IpAdr
[Explanation] Not used.
[Default] None
_MC02IpAdr
[Explanation] Not used.
[Default] None
_MCNickName O
[Explanation This is used by remote files, and is required when Proper data item
[_PCFtpUse] is enabled. This is also the nickname specified for the
machine.
[Default] None
_LoggingHostAddr O
[Explanation] IP address of the server receiving the production information log.
[Default] None
1.37 PART_VERIFICATION
_CommentTermCode 1 character O
[Explanation] Comments enclosed by the code specified in this item are ignored.
[Default] None
_VerifierTermCode 1 character O
[Explanation] Comments following the code specified in this item are ignored.
[Default] None
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-56 XP-142E System Reference
Part 7
I/O Map
(ESR05AA)
This part contains a list of the input
signals from sensors and switches
etc., and the output signals to
actuators. (Press [Maintenance] -
[I/O Check A] from the [Main]
screen.)
1. System Input Signals . . . . . . . . . . . . . . . . .7-1-1
2. System Output Signals . . . . . . . . . . . . . . .7-2-1
1. System Input Signals
(ESR0501h)
Address Display Description Option Logic
X000 StartButton Start PB NO
X001 ReadyOnButton READY ON PB NO
X002 Side1Enable Side 1 operation enabled NO
X003 Side1Lock Side 1 operation lock NO
X004 Side2Enable Side 2 operation enabled NO
X005 Side2Lock Side 2 operation lock NO
X006 EmergencyBtn Emergency stop PB NC
X007 CycleStopBtn Cycle stop PB NC
X008 Maint.ModeOn Maintenance mode on NC
X009 Side1SftyCovChk Safety cover check (Side 1) NC
X00A Side2SftyCovChk Safety cover check (Side 2) NC
X00B
X00C SafetyRelayLock Safety relay OK NC
X00D ThermalOk Thermal relay OK NC
X00E
X00F PressureSwOk Air pressure OK NC
X010 TimePassed2000h 2000h elapsed NO
X011 TimePassed6000h 6000h elapsed NO
X012 ResetCylUpChk Reset cylinder upper limit check NO
X013 ZAxisMtrFanChk Z-axis motor fan check NC
X014
X015
X016
X017 Side1XYAxisInter XY-Axis Interlock (Side 1) NC
X018 PcbAvailable Panel unloading enabled” signal from previous machine NO
X019 PcbRequest Panel request” signal from next machine NO
X01A Side2XYAxisInter XY-Axis Interlock (Side 2) NC
X01B InStArriveChk IN station panel arrival check NO
X01C MainStDecelPnt MAIN station panel deceleration start point NO
X01D MainStArriveChk MAIN station panel arrival check NO
X01E MainStStpOnChk MAIN station stopper on check NO
X01F MainStStpOffChk MAIN station stopper off check NO
Part 7 Chapter 1 System Input Signals
Edition 2.0 7-1-1 XP-142E System Reference