Code: 1101D32A Display: The part size or Scan Area X, Scan Area Y setting exceeds the scanning range that can be handled by the camera. Cause: The part size or Scan Area X, Scan Area Y setting exceeds the scanning range …

100%1 / 344
Code: 1101D31F
Display: The value set for Stand Off height is higher than or equal to the Part Height.
Cause: The value set for Stand Off height is higher than or equal to the Part Height.
Remedy: Enter a value lower than the Part Height.
Code: 1101D320
Display: The Z-axis target value exceeds the servo limit.
Placing Offset Z = *** (Min.: ***)
Cause: Operation with this part data causes the Z-axis to pass the minus limit.
Remedy: In Part Type Data, revise the Placing Offset Z value.
If there is no problem with the Placing Offset Z value, confirm the Part Height
value.
Code: 1101D321
Display: Parts using vision type 230 or 231 require at least one element with lead quantity
of two or more. (Excluding the second row of data in the matrix display.)
Cause: The element data for parts using vision type 230 or 231 does not have an element
with two or more leads.
Remedy: When using vision type 230 or 231, create at least one element with lead quantity
of two or more.
Code: 1101D322
Display: 2 or more Element lines are required for Vision Type 20.
Cause: For Vision Type 20, vision processing is only possible when the “Element” setting
occupies 2 or more lines.
Remedy: Specify 2 or more lines for the “Element” setting.
Code: 1101D323
Display: For Vision Type 124, the [Element] setting must occupy either 2 or 4 lines.
Cause: For Vision Type 124, vision processing is only possible when the “Element” setting
occupies either 2 or 4 lines.
Remedy: Specify either 2 or 4 lines for the “Element” setting.
Code: 1101D324
Display: For Vision Type 180, the total number of leads in [Lead Quantity] for the entire
element must be 2, 3, or 4.
Cause: For Vision Type 180, the total number of leads in “Lead Quantity” for the entire
element must be 2, 3, or 4.
Remedy: When using Vision Type 180, set the values for “Lead Quantity” so that the sum of
all leads for the element equals 2, 3, or 4.
Code: 1101D329
Display: The specified part size exceeds the scanning range (body length (X): 5 mm or less,
body width (Y): 4 mm or less) that can be handled by the camera for vision type
10.
Cause: The maximum part dimensions that may be specified when using vision type 10
are 5 mm for the body length (X) and 4 mm for the body width (Y). If the specified
part size exceeds these dimensions, the part may not be found or accuracy may be
negatively affected.
Remedy: When using vision type 10, only use parts with maximum dimensions of 5 mm for
the body length (X), and 4 mm for the body width (Y). For larger parts, create the
part data using vision type 18.
Part 8 Chapter 1 Error Code Messages and Corrective Measures
Edition 2.0 8-1-8 XP-142E System Reference
Code: 1101D32A
Display: The part size or Scan Area X, Scan Area Y setting exceeds the scanning range that
can be handled by the camera.
Cause: The part size or Scan Area X, Scan Area Y setting exceeds the scanning range that
can be handled by the camera.
Remedy: Specify a part size or Scan Area X, Scan Area Y setting value that is within the
scanning range that can be handled by the camera.
With the Pick-up Point Offset X and Pick-up Point Offset Y settings taken into
account, the maximum part size that may be specified is 20 mm x 20 mm, and the
maximum scan area is 25 mm x 24 mm,
Code: 1101D32B
Display: A nozzle that matches nozzle no. ** cannot be found.
Cause: A nozzle that matches nozzle no. ** cannot be found.
Remedy: Specify a matching nozzle in the nozzle data.
Code: 1101D32C
Display: The part cannot be picked up because it interferes with an adjacent nozzle.
Cause: The part cannot be picked up because it interferes with an adjacent nozzle.
Remedy: Change the nozzle configuration.
Code: 1101D32D
Display: The part will not be picked up at its center so as to prevent part interference (Y-
offset amount: *.* mm).
Cause: The part will not be picked up at its center, as the offset function is in use for
automatic interference prevention.
Remedy: To specify pick-up at the part center, set Pick-up Point Offset Y to 0.1, or set Scan
Area Y to 23 or less.
Code: 1101D32E
Display: There is a possibility of interference with nozzle no. **.
Cause: A corner of the part may interfere with nozzle no. **.
Remedy: Check the part shape, and if there is a possibility of interference, change either the
nozzle size or nozzle position.
Code: 1101D32F
Display: 5 or more leads do not exist, or the part exceeds the scan range that can be handled
by the camera.
Cause: 5 or more leads are required. Where 5 or more leads exist, and the part is picked
up at the revolver center, the part exceeds the scan range that can be handled by
the camera.
Remedy: Create the part data using vision type 18 or 20.
Code: 1101D330
Display: No template data exists.
Cause: Template data is required for Vision Type 18 in part data.
Remedy: If the error occurred even though template file reading using
_CCIMFTemplateMode in Proper data is specified, then create template data.
When using an existing template file, specify that the template file is read.
Part 8 Chapter 1 Error Codes and Corrective Measures
Edition 2.0 8-1-9 XP-142E System Reference
Code: 1101D331
Display: Feed pitch is incorrect. The current feed pitch of ** was extrapolated from the
packaging name data.
Cause: The feed pitch is incorrect. The current feed pitch was extrapolated from the
packaging name data.
Remedy: If there is a problem with the extrapolated feed pitch, then specify the correct feed
pitch.
Code: 1101D332
Display: Feed pitch is incorrect. The current feed pitch is 2.
Cause: Feed pitch is incorrect. The current feed pitch is 2.
Remedy: If there is a problem with feed pitch of 2, then specify the correct feed pitch.
Code: 1101D333
Display: When performing the template command for a Vision Type other than 18, specify
Body Length (X) and Body Width (Y).
Cause: When performing the template command for a Vision Type other than 18, specify
Body Length (X) and Body Width (Y).
Remedy: Specify body length (X) and body width (Y), or change the vision type to 18.
Code: 1101D334
Display: The part size, Scan Area X, or Scan Area Y exceeds the vision processing range for
Front Sidelight (20 x 20).
Cause: The part size, Scan Area X, or Scan Area Y exceeds the vision processing range for
Front Sidelight (20 x 20).
Remedy: Specify camera position “0: Auto” or “2: Rear”.
Code: 1101D335
Display: When setting the Scan Area, set both Scan Area X and Scan Area Y at the same
time.
Cause: Only Scan Area X or Scan Area Y is set.
Remedy: When setting the Scan Area, set both Scan Area X and Scan Area Y at the same
time.
Code: 1101D3F0
Display: Compile error.
Cause: Vision processing Data Error
Remedy: Cannot read the part data.
Either the part data format or the part data is incorrect.
Revise the applicable part data.
Also, if the part data is administered over a network, check the network.
Code: 1101D3F1
Display: Compile error.
Cause: Vision processing Data Error
Remedy: Cannot read the part data.
Either the part data format or the part data is incorrect.
Revise the applicable part data.
Also, if the part data is administered over a network, check the network.
Part 8 Chapter 1 Error Code Messages and Corrective Measures