Code: 1404D008 Display: A foreign substance has been detected on the nozzle. Vision processing may not perform correctly. Cause: A foreign substance has been detected on the nozzle. Vision processing may not perform corr…

100%1 / 344
Code: 1404D000
Display: Mechanical chuck part transportation error. If the mechanical chuck is holding the
part, manually remove it from the chuck.
Cause: Mechanical chuck part transportation error.
Remedy: If the mechanical chuck is holding the part, manually remove it from the chuck. If
the mark is dirty remove the mechanical chuck and clean the mark.
Code: 1404D001
Display: Compile error.
Cause: Vision processing Data Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 1404D003
Display: Nozzle vision processing failed during cycle steal
Cause: Nozzle vision processing failed during cycle steal.
Check nozzle for scratches or foreign matter.
Check light radiation of strobe light.
Code: 1404D005
Display: A foreign matter was detected on the nozzle surface. Check that all parts have
been placed on the panel.
Cause: A foreign matter was detected on the nozzle surface.
Remedy: Check nozzle surface for foreign matter.
Code: 1404D006
Display: Nozzle center could not be detected.
Cause: Nozzle center could not be detected.
Remedy: Check that the nozzle diameter is correct.
Check that the surface of the nozzle is not scratched or dirty.
Check that the strobe light is emitting light properly.
Code: 1404D007
Display: Nozzle size check error
An error occurred while performing nozzle size check by vision processing.
Check that the machine nozzles match the nozzle settings in the data editor.
Check nozzle for scratches or foreign matter.
Check light radiation of strobe light.
Cause: An error occurred while performing nozzle size check by vision processing.
Remedy: Check that the machine nozzles match the nozzle settings in the data editor.
Check nozzle for scratches or foreign matter.
Check light radiation of strobe light.
Part 8 Chapter 1 Error Code Messages and Corrective Measures
Edition 2.0 8-1-38 XP-142E System Reference
Code: 1404D008
Display: A foreign substance has been detected on the nozzle. Vision processing may not
perform correctly.
Cause: A foreign substance has been detected on the nozzle. Vision processing may not
perform correctly.
Remedy: Check and correct the following conditions.
• Check the nozzle where the error is occurring for foreign substances, blemishes,
or scratches. Clean or replace the nozzle as necessary.
• Check the prism on the side where the error is occurring, and clean as
necessary.
• Check that a nozzle is mounted within the vision processing range. Install a
nozzle if one is not within the correct range. (XP142)
• If the camera image is too dark or light, the brightness setting is not correct.
Adjust brightness as specified in the manual.
• Check the vision processing position. If not correct adjust as specified in the
manual.
• If the strobe light is not working properly there may be a problem with the light
source. Check the wiring and replace the xenon bulb or servo PCB as necessary.
• If the camera image is not reading properly, there may be a problem with the
camera. Check the wiring and replace the camera or vision PCB as necessary.
Code: 14050000
Display: Corner dog vision error
Cause: Corner dog vision error
Remedy: Perform vision processing to confirm the corner dog adjustment.
Code: 14050001
Display: Corner dog limit error
Cause: Corner dog limit error
Remedy: Check a part was not mistakenly read during corner dog processing. Check the
corner dog has not come loose.
Code: 14050002
Display: Corner dog vision processing failed during cycle steal
Cause: Corner dog vision processing failed during cycle steal.
Remedy: Check vision processing at [Maintenance A] - [Corner Dog Adjustment].
If an error occurs, check the corner dog for scratches or foreign matter.
Code: 14050003
Display: Pick-up position measurement failed.
Cause: Failed to acquire an image of the feeder pick-up point when performing pick-up
position measurement.
Remedy: Check that the feeder is set correctly.
Check that the tape leaf position is correct.
Check that the parts tape is set correctly on the feeder.
Code: 14050004
Display: Failed to the read gauge chip during cycle steal.
Cause: Failed to the read gauge chip during cycle steal.
Remedy: Check gauge chip cleanliness and size.
Part 8 Chapter 1 Error Codes and Corrective Measures
Edition 2.0 8-1-39 XP-142E System Reference
Code: 14050005
Display: Failed to the read glass parts during cycle steal.
Cause: Failed to the read glass parts during cycle steal.
Remedy: Check glass parts cleanliness and size.
Code: 15031008
Display: Failed to lift off the in station lifter
Cause: Unable to lift off this in station lifter.
Remedy: If the IN station lifter is down, check the hoses to the lifter are not loose.
If the IN station lifter is up, check the function of the IN lifter sensor.
Code: 15031009
Display: Failed to lift down the in station lifter
Cause: Unable to lower the IN station lifter.
Remedy: Check that the IN lifter sensor is functioning correctly. Check the hoses to the
lifter are not loose.
Code: 1503100A
Display: Failed to lift off the main station lifter
Cause: Unable to raise the main station lifter.
Remedy: If the main station lifter is not raised, check the hoses to the lifter have not come
loose.
If the main station lifter is raised check the sensor is functioning correctly.
Code: 1503100B
Display: Failed to lift down the main station lifter
Cause: Unable to lower the main station lifter.
Remedy: If the main station lifter is not lowered, check the hoses to the lifter have not come
loose.
If the main station lifter is lowered check the sensor is functioning correctly.
Code: 1503100C
Display: Failed to lift off the main station stopper
Cause: Unable to raise the main station stopper.
Remedy: If the main station stopper is not raised, check the hoses to the lifter have not come
loose.
If the main station stopper is raised check the sensor is functioning correctly.
Check the hoses to the lifter have not come loose.
Code: 1503100D
Display: Failed to lower the main station stopper
Cause: Unable to lower the main station stopper.
Remedy: If the main station stopper is not lowered, check the hoses to the lifter have not
come loose.
If the main station stopper is lowered check the sensor is functioning correctly.
Code: 1503100E
Display: Failed to convey a panel to at the main station arrival sensor
Cause: Unable to convey a panel to the main station arrival sensor.
Remedy: Check the panel is not stuck on the conveyor, and the main station arrival sensor is
functioning correctly.
Part 8 Chapter 1 Error Code Messages and Corrective Measures