XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第262页
1.21 DISPOSE_POSITION X_Disposal1 X [Explanation] Sets the X-coordinate position for discarding small size reject parts in the reject box (mark camera reference). [Default] Proper data measurement result. X_Disposal2 – […

_NzlPosOffsetX4 –
[Explanation] Not used.
[Default] 0
_NzlPosOffsetY4 –
[Explanation] Not used.
[Default] 0
_NzlPosOffsetX5 –
[Explanation] Not used.
[Default] 0
_NzlPosOffsetY5 –
[Explanation] Not used.
[Default] 0
_NzlPosOffsetX6 –
[Explanation] Not used.
[Default] 0
_NzlPosOffsetY6 –
[Explanation] Not used.
[Default] 0
_NzlPosOffsetX7 –
[Explanation] Not used.
[Default] 0
_NzlPosOffsetY7 –
[Explanation] Not used.
[Default] 0
_NzlPosOffsetX8 –
[Explanation] Not used.
[Default] 0
_NzlPosOffsetY8 –
[Explanation] Not used.
[Default] 0
_NzlPosOffsetX9 –
[Explanation] Not used.
[Default] 0
_NzlPosOffsetY9 –
[Explanation] Not used.
[Default] 0
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-35 XP-142E System Reference

1.21 DISPOSE_POSITION
X_Disposal1 X
[Explanation] Sets the X-coordinate position for discarding small size reject parts in
the reject box (mark camera reference).
[Default] Proper data measurement result.
X_Disposal2 –
[Explanation] Not used.
[Default] 0
Y_Disposal1 X
[Explanation] Sets the Y-coordinate position for discarding small size reject parts in
the reject box (mark camera reference).
[Default] Proper data measurement result.
Y_Disposal2 –
[Explanation] Not used.
[Default] 0
Z_Disposal2 –
[Explanation] Not used.
[Default] 0
1.22 PRISM_POSITION
_PrismFront X
[Explanation] Sets the side 1 camera’s image acquisition position (mm).
[Default] Proper data measurement result.
_PrismBack X
[Explanation] Sets the side 2 camera’s image acquisition position (mm).
[Default] Proper data measurement result.
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-36 XP-142E System Reference

1.23 JIG_POSITION
X_JigPickPos1 X
[Explanation] Sets the XP-142E jig’s (large) X-coordinate pickup position, XP-242E
jig’s X-coordinate pickup position jig’s X-coordinate pickup position.
[Default] Proper data measurement result.
X_JigPickPos2 X
[Explanation] Sets the jig’s (medium) X-coordinate pickup position.
[Default] Proper data measurement result.
X_JigPickPos3 X
[Explanation] Sets the jig’s (small) X-coordinate pickup position.
[Default] Proper data measurement result.
Y_JigPickPos X
[Explanation] Sets the jig’s Y-coordinate pickup position.
[Default] Proper data measurement result.
Z_JigPickPos X
[Explanation] Sets the jig’s Z-coordinate pickup height.
[Default] Proper data measurement result.
1.24 ELEGANCE
_PlaceEleganceQ –
[Explanation] Not used.
[Default] 0
_PlaceUpSpeedRatio 0 ~ 1.00 O
[Explanation] Speed coefficient for UP motion after placement. (Applies only for
Vision Types 100 and 20.)
[Default] 0
_PlaceUpMaxSpeed 0 ~ 1500.0 O
[Explanation] Maximum speed reference for Z-axis speed after part placement.
[Default] 1500
_CycleStealElegance 0.01 ~ 1.00 O
[Explanation] Set the elegance value for the cycle steal after the time set at proper
data item “_CycleStealStartTime” elapses.
[Default] 1
_MainteMaxVRatio 0.01 ~ 1.00 X
[Explanation] Specifies the speed ratio when in maintenance mode.
[Default] 0.1
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-37 XP-142E System Reference