XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第239页
1.6 P ARTS_CAMERA_UNIT _Side1UnitX X [Explanation] Sets the side 1 standard height unit X position. [Default] Proper data measurement result. _Side1UnitY X [Explanation] Sets the side 1 standard height unit Y position. […

_CCIMFTemplateMode 0:1 O
[Explanation] Setting for responding when template data is not found in the
production program (recipe) and vision type 18 is specified in part
data. Either an error occurs during data check, or the template data is
retrieved from the template file (.TPL).
0: Error
1: Retrieve from template file
[Default] 0
_BrightCheckErrorMode 0:1 O
[Explanation] Specifies whether or not to terminate production when a nozzle
brightness measurement error occurs..
0: Error stop
1: Error pass
[Default] 0
1.5 VISION
_FiducialMarkImperfect 0:1 OR
[Explanation] Set whether partial circle fiducial marks are supported or not.
0: Not supported
1: Supported
[Default] 0
_FiducialMeasureFailRatio 0 ~ 100 O
[Explanation] In order to enable the measure seek line failure ratio (%) setting, the
program must be reread and compiled.
[Default] 0
_BoardSkipMarkBrightnessLevel 0~ 255 O
[Explanation] Set the brightness level reading board skip marks. Values from 1 to
255 are valid. If a value of 0 or lower, or 256 or higher is specified, the
default value of 128 will be used.
[Default] 0
_LookUpTableOff 0:1 O
[Explanation] Specifies whether or not the machine performs image contrast offset
using the [Gain of Contrast Offset] value from part data.
[Default] 0: Used
1: Not used
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-12 XP-142E System Reference

1.6 PARTS_CAMERA_UNIT
_Side1UnitX X
[Explanation] Sets the side 1 standard height unit X position.
[Default] Proper data measurement result.
_Side1UnitY X
[Explanation] Sets the side 1 standard height unit Y position.
[Default] Proper data measurement result.
_Side1UnitX_Low X
[Explanation] Sets the side 1 low height unit X position.
[Default] Proper data measurement result.
_Side1UnitY_Low X
[Explanation] Sets the side 1 low height unit Y position.
[Default] Proper data measurement result.
_Side2UnitX X
[Explanation] Sets the side 2 standard height unit X position.
[Default] Proper data measurement result.
_Side2UnitY X
[Explanation] Sets the side 2 standard height unit Y position.
[Default] Proper data measurement result.
_Side2UnitX_Low X
[Explanation] Sets the side 2 low height unit X position.
[Default] Proper data measurement result.
_Side2UnitY_Low X
[Explanation] Sets the side 2low height unit Y position.
[Default] Proper data measurement result.
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-13 XP-142E System Reference

1.7 Machine_TYPE_2
_MachineParameter1 –
[Explanation] Not used.
[Default] 0
_StageModeSW 0:1:2 XR
[Explanation] Stage mode (AA mode) function setting.
0: Standard machines
1, 2: Standard stage change mode machines
[Default] 0
_RemoverType –
[Explanation] Not used.
[Default] 0
_FiducailLampType –
[Explanation] Not used.
[Default] 0
_TrayRetractCheck –
[Explanation] Not used.
[Default] 0
_TrayUnitType –
[Explanation] Not used.
[Default] 0
_UseMicroTray –
[Explanation] Not used.
[Default] 0
_SetDetectSensorSW 0:1 XR
[Explanation] Set whether the tape leaf sensor is used or not.
0: Unsupported
1: Tape leaf W sensor.
[Default] 0
_EjectPanelUncondtion 0:1:2 O
[Explanation] Set the machine action for when, during panel eject, the panel request
signal from the next machine is terminated while the panel is passing
the MAIN or OUT pass sensor.
0: Default
1: Continue eject panel processing
2: Force eject panel to next machine
[Default] 0
_VerifierTool 0:1 O
[Explanation] Sets hardware used by parts verifier
0: Do not use
1: Wireless barcode reader (local verifier)
[Default] 0
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-14 XP-142E System Reference