XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第291页

Code: 1101C70D Display: Duplicate “Ref” (“Sequence Comment”) sequences exist for the same board. Cause: Duplicate “Ref” (“Sequence Comment”) sequences exist for the same board. Remedy: Create sequences so that “Ref” (“Se…

100%1 / 344
Part 8 Chapter 1 Error Code Messages and Corrective Measures
Edition 2.0 8-1-2 XP-142E System Reference
Code: 1101C706
Display: The main mark number is the same as the sub mark number.
Cause: The same setting value is specified for both the main mark number and the sub-
mark number in the part placement sequence.
Remedy: Specify setting values so that the main mark number and sub-mark number are
different.
Code: 1101C707
Display: Cannot locate the mark sequence for the mark No. specified at main mark No.
Cause: A fiducial mark reading sequence which contains the specified (in the part
placement sequence) main mark number cannot be found.
Remedy: Set the fiducial mark reading sequence for the specified main mark number to
occur before the part placement sequence.
Code: 1101C708
Display: Cannot locate the mark sequence for the mark No. specified at sub mark No.
Cause: A fiducial mark reading sequence which contains the specified (in the part
placement sequence) sub-mark number cannot be found.
Remedy: Set the fiducial mark reading sequence for the specified sub-mark number to occur
before the part placement sequence.
Code: 1101C709
Display: The stage number and slot number are not defined.
Cause: No setting data exists for the stage number and slot number specified in the
sequence data.
Remedy: Either specify settings for the stage number and slot number in the feeder setup
data, or specify a stage number and slot number for which setting data already
exists.
Code: 1101C70A
Display: Board skip settings of “0” and “1” have both been specified in the sequence data
for the same board.
Cause: Sequence data with and without board skip settings exist for the same board.
Remedy: Correct the sequence data so that all sequences for the same board have the same
board skip settings.
Code: 1101C70B
Display: The “Ref” (“Sequence Comment”) sequence specified for the “Place Before”
sequence does not exist on the same board.
Cause: The “Ref” (“Sequence Comment”) sequence specified for the “Place Before”
sequence does not exist on the same board.
Remedy: Specify a “Ref” (“Sequence Comment”) sequence that applies to the same board as
that of the “Place Before” sequence.
The “Place Before” sequence is ignored where the “Ref” (“Sequence Comment”)
sequence does not apply to the same board.
Code: 1101C70C
Display: The same name has been allocated to “Place Before” and “Ref” (“Sequence
Comment”).
Cause: The same name has been allocated to the “Place Before” and “Ref” (“Sequence
Comment”) sequences.
Remedy: Specify different names for the “Place Before” and “Ref” (“Sequence Comment”)
sequences.
Code: 1101C70D
Display: Duplicate “Ref” (“Sequence Comment”) sequences exist for the same board.
Cause: Duplicate “Ref” (“Sequence Comment”) sequences exist for the same board.
Remedy: Create sequences so that “Ref” (“Sequence Comment”) sequences are not
duplicated for the same board.
Code: 1101C70E
Display: The “Place Before” sequence order is incorrect.
Cause: The “Place Before” sequence order is incorrect.
Remedy: Change the “Place Before” sequence order so that the “Place Before” sequence is
positioned before the “Ref” (“Sequence Comment”) sequence.
Code: 1101C70F
Display: An unavailable stage is set in the sequence data.
Cause: Stage 2 is set in the sequence data for the single side parts supplying machine.
Remedy: Either skip all of the sequence data specified in stage 2, or delete or move them to
stage 1.
Code: 1101D200
Display: If a joint mode is not specified, stage 2 cannot be set in the feeder setup data.
Cause: If joint mode is not specified, stage 2 cannot be set in the feeder setup data.
Remedy: Delete the stage 2 feeder data.
Code: 1101D201
Display: The part data is not found.
Cause: Data corresponding to the part number does not exist.
Remedy: Create the specified part number data, or specify an existing part number.
Code: 1101D202
Display: The Alt. Feeder number must be set to a separate feeder.
Cause: The slot number and next slot number are identical.
Remedy: Specify a “next slot” number which is different from the slot number.
Code: 1101D203
Display: A slot that has not been allocated a part number is set as an alternative slot.
Cause: A vacant slot number (no setting data) is set as the “next slot” number.
Remedy: Specify a slot number with a same part number.
Code: 1101D204
Display: The part number does not match that of the Alt. Feeder.
Cause: A slot number with a different part number setting has been specified as the “next
slot”.
Remedy: Specify a slot number with a same part number setting for use as the “next slot”.
Code: 1101D205
Display: The stage No./slot No. does not match the packaging type in part data.
Cause: A part number with a Packaging Type of “Tray” is set for a Feeder stage number
and slot number, or, a part number with a Packaging Type other than “Tray” is set
for a Tray stage number and slot number.
Remedy: For Feeder stage numbers and slot numbers, specify a part number with a
Packaging Type other than “Tray”. For Tray stage numbers and slot numbers,
specify a part number with Packaging Type of “Tray”.
Part 8 Chapter 1 Error Codes and Corrective Measures
Edition 2.0 8-1-3 XP-142E System Reference
Code: 1101D206
Display: The Alt. Feeder does not form a loop.
Cause: The next slot number does not have a loop structure.
Remedy: Set the next slot number so that a loop structure is created.
Code: 1101D207
Display: An unavailable stage is set in the feeder setup data.
Cause: Stage 2 is set in the feeder setup data for the single side parts supplying machine.
Remedy: Either delete the stage 2 feeder data, or move them to stage 1.
Code: 1101D300
Display: The Polarity Setting item”s [Not Use] setting is not supported.
Cause: XP-series machines do not support Polarity Setting”s “Not Use” setting. (Except
for program data transmitted from MCS/2.)
Remedy: Set the Polarity Setting to another setting.
Code: 1101D301
Display: The “Not Use” setting for the “Polarity Setting” item is not supported for MCS/2
programs received by XP-1-series machines.
Cause: MCS/2 programs received by XP-1-series machines with the “Polarity Setting”
item set to “Not Use” may only be used on XP-1-series machines.
Remedy: Set the “Polarity Setting” item to a setting other than “Not Use”.
Code: 1101D302
Display: The “Not Use” setting for the “Polarity Setting” item is not supported for MCS/2
programs received by XP-2 / XP-3-series machines.
Cause: MCS/2 programs received by XP-2 / XP-3-series machines with the “Polarity
Setting” item set to “Not Use” may only be used on XP-2 / XP-3-series machines.
Remedy: Set the “Polarity Setting” item to a setting other than “Not Use”.
Code: 1101D303
Display: The element data is required when the vision type is other than 10 or 18.
Cause: There is no ElementData although a Vision Type other than 10 or 18 is specified.
Remedy: Set the ElementData.
Code: 1101D305
Display: The settings at Scan Area X and Scan Area Y are outside the range that can be
handled by the Front (Rear) camera (short side: **.***; long side: **.***).
Cause: The settings at “Scan Area X” and “Scan Area Y” are outside the range that can be
handled by the Front (Rear) camera.
Remedy: Compare “Scan Area X” with “Scan Area Y.” The one with the lower value should
be set to be shorter than the short side of the field of view, and the one with the
higher value should be set to be shorter than the long side.
Code: 1101D306
Display: A setting of [128] exists at two consecutive Result lines for the Element item of a
Vision Type 230 or 231 part.
Cause: A setting of “128” exists at two consecutive Result lines for the Element item of a
Vision Type 230 or 231 part.
Remedy: Do not specify a “128” setting at two consecutive Result lines for the Element item
of a Vision Type 230 or 231 part.
Part 8 Chapter 1 Error Code Messages and Corrective Measures
Edition 2.0 8-1-4 XP-142E System Reference