1.7 Machine_TYPE_2 _MachineParameter1 – [Explanation] Not used. [Default] 0 _StageModeSW 0:1:2 XR [Explanation] Stage mode (AA mode) function setting. 0: Standard machines 1, 2: Standard stage change mode machines [Defau…

100%1 / 344
1.6 PARTS_CAMERA_UNIT
_Side1UnitX X
[Explanation] Sets the side 1 standard height unit X position.
[Default] Proper data measurement result.
_Side1UnitY X
[Explanation] Sets the side 1 standard height unit Y position.
[Default] Proper data measurement result.
_Side1UnitX_Low X
[Explanation] Sets the side 1 low height unit X position.
[Default] Proper data measurement result.
_Side1UnitY_Low X
[Explanation] Sets the side 1 low height unit Y position.
[Default] Proper data measurement result.
_Side2UnitX X
[Explanation] Sets the side 2 standard height unit X position.
[Default] Proper data measurement result.
_Side2UnitY X
[Explanation] Sets the side 2 standard height unit Y position.
[Default] Proper data measurement result.
_Side2UnitX_Low X
[Explanation] Sets the side 2 low height unit X position.
[Default] Proper data measurement result.
_Side2UnitY_Low X
[Explanation] Sets the side 2low height unit Y position.
[Default] Proper data measurement result.
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-13 XP-142E System Reference
1.7 Machine_TYPE_2
_MachineParameter1
[Explanation] Not used.
[Default] 0
_StageModeSW 0:1:2 XR
[Explanation] Stage mode (AA mode) function setting.
0: Standard machines
1, 2: Standard stage change mode machines
[Default] 0
_RemoverType
[Explanation] Not used.
[Default] 0
_FiducailLampType
[Explanation] Not used.
[Default] 0
_TrayRetractCheck
[Explanation] Not used.
[Default] 0
_TrayUnitType
[Explanation] Not used.
[Default] 0
_UseMicroTray
[Explanation] Not used.
[Default] 0
_SetDetectSensorSW 0:1 XR
[Explanation] Set whether the tape leaf sensor is used or not.
0: Unsupported
1: Tape leaf W sensor.
[Default] 0
_EjectPanelUncondtion 0:1:2 O
[Explanation] Set the machine action for when, during panel eject, the panel request
signal from the next machine is terminated while the panel is passing
the MAIN or OUT pass sensor.
0: Default
1: Continue eject panel processing
2: Force eject panel to next machine
[Default] 0
_VerifierTool 0:1 O
[Explanation] Sets hardware used by parts verifier
0: Do not use
1: Wireless barcode reader (local verifier)
[Default] 0
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-14 XP-142E System Reference
1.8 CAMERA_UNIT
_Camera0UnitX X
[Explanation] Sets the camera no. 0 unit value X.
[Default] Proper data measurement result.
_Camera0UnitY X
[Explanation] Sets the camera no. 0 unit value Y.
[Default] Proper data measurement result.
_Camera1UnitX X
[Explanation] Sets the camera no. 1 unit value X.
[Default] Proper data measurement result.
_Camera1UnitY X
[Explanation] Sets the camera no. 1 unit value Y.
[Default] Proper data measurement result.
_Camera1UnitX_Low X
[Explanation] Sets the camera no. 1 unit low poisition value X.
[Default] Proper data measurement result.
_Camera1UnitY_Low X
[Explanation] Sets the camera no. 1 unit low position value Y.
[Default] Proper data measurement result.
_Camera2UnitX X
[Explanation] Sets the camera no. 2 unit value X.
[Default] Proper data measurement result.
_Camera2UnitY X
[Explanation] Sets the camera no. 2 unit value Y.
[Default] Proper data measurement result.
_Camera3UnitX X
[Explanation] Sets the camera no. 3 unit value X.
[Default] Proper data measurement result.
_Camera3UnitY X
[Explanation] Sets the camera no. 3 unit value Y.
[Default] Proper data measurement result.
_Camera4UnitX X
[Explanation] Sets the camera no. 4 unit value X.
[Default] Proper data measurement result.
_Camera4UnitY X
[Explanation] Sets the camera no. 4 unit value Y.
[Default] Proper data measurement result.
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-15 XP-142E System Reference