_BMLSide2Nzl11 0 ~ 255.0000 X [Explanation] Specifies the black mask level for each nozzle. (This is used only when the proper item “_BlackMaskLevel” is set to - 1.) [Default] Proper data measurement result. _BMLSide2Nzl…

100%1 / 344
_BMLSide2Nzl2 0 ~ 255.0000 X
[Explanation] Specifies the black mask level for each nozzle.
(This is used only when the proper item “_BlackMaskLevel” is set to -
1.)
[Default] Proper data measurement result.
_BMLSide2Nzl3 0 ~ 255.0000 X
[Explanation] Specifies the black mask level for each nozzle.
(This is used only when the proper item “_BlackMaskLevel” is set to -
1.)
[Default] Proper data measurement result.
_BMLSide2Nzl4 0 ~ 255.0000 X
[Explanation] Specifies the black mask level for each nozzle.
(This is used only when the proper item “_BlackMaskLevel” is set to -
1.)
[Default] Proper data measurement result.
_BMLSide2Nzl5 0 ~ 255.0000 X
[Explanation] Specifies the black mask level for each nozzle.
(This is used only when the proper item “_BlackMaskLevel” is set to -
1.)
[Default] Proper data measurement result.
_BMLSide2Nzl6 0 ~ 255.0000 X
[Explanation] Specifies the black mask level for each nozzle.
(This is used only when the proper item “_BlackMaskLevel” is set to -
1.)
[Default] Proper data measurement result.
_BMLSide2Nzl7 0 ~ 255.0000 X
[Explanation] Specifies the black mask level for each nozzle.
(This is used only when the proper item “_BlackMaskLevel” is set to -
1.)
[Default] Proper data measurement result.
_BMLSide2Nzl8 0 ~ 255.0000 X
[Explanation] Specifies the black mask level for each nozzle.
(This is used only when the proper item “_BlackMaskLevel” is set to -
1.)
[Default] Proper data measurement result.
_BMLSide2Nzl9 0 ~ 255.0000 X
[Explanation] Specifies the black mask level for each nozzle.
(This is used only when the proper item “_BlackMaskLevel” is set to -
1.)
[Default] Proper data measurement result.
_BMLSide2Nzl10 0 ~ 255.0000 X
[Explanation] Specifies the black mask level for each nozzle.
(This is used only when the proper item “_BlackMaskLevel” is set to -
1.)
[Default] Proper data measurement result.
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-49 XP-142E System Reference
_BMLSide2Nzl11 0 ~ 255.0000 X
[Explanation] Specifies the black mask level for each nozzle.
(This is used only when the proper item “_BlackMaskLevel” is set to -
1.)
[Default] Proper data measurement result.
_BMLSide2Nzl12 0 ~ 255.0000 X
[Explanation] Specifies the black mask level for each nozzle.
(This is used only when the proper item “_BlackMaskLevel” is set to -
1.)
[Default] Proper data measurement result.
_BMLSide2Nzl1B 0 ~ 255.0000 X
[Explanation] Specifies the black mask level for each nozzle.
(This is used only when the proper item “_BlackMaskLevel” is set to -
1.)
[Default] Proper data measurement result.
_BMLSide2Nzl4B 0 ~ 255.0000 X
[Explanation] Specifies the black mask level for each nozzle.
(This is used only when the proper item “_BlackMaskLevel” is set to -
1.)
[Default] Proper data measurement result.
_BMLSide2Nzl7B 0 ~ 255.0000 X
[Explanation] Specifies the black mask level for each nozzle.
(This is used only when the proper item “_BlackMaskLevel” is set to -
1.)
[Default] Proper data measurement result.
_BMLSide2Nzl10B 0 ~ 255.0000 X
[Explanation] Specifies the black mask level for each nozzle.
(This is used only when the proper item “_BlackMaskLevel” is set to -
1.)
[Default] Proper data measurement result.
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-50 XP-142E System Reference
1.34 OTHERS
X_MeasureFidMark X
[Explanation] Sets the “Measure fiducial mark” X-coordinate (mm).
[Default] Proper data measurement result.
Y_MeasureFidMark X
[Explanation] Sets the “Measure fiducial mark” Y-coordinate (mm).
[Default] Proper data measurement result.
X_MeasureFidMark2 X
[Explanation] Sets the “Measure fiducial mark 2” X-coordinate (mm).
[Default] Proper data measurement result.
Y_MeasureFidMark2 X
[Explanation] Sets the “Measure fiducial mark 2” Y-coordinate (mm).
[Default] Proper data measurement result.
X_MeasureFidMark3 X
[Explanation] Sets the “Measure fiducial mark 3” X-coordinate (mm).
[Default] Proper data measurement result.
Y_MeasureFidMark3 X
[Explanation] Sets the “Measure fiducial mark 3” Y-coordinate (mm).
[Default] Proper data measurement result.
_ConvWidthMtrSpeed X
[Explanation] Sets the conveyor speed (mm/sec).
[Default] Proper data measurement result.
_ConvWidthOffset X
[Explanation] Sets the conveyor width offset at conveyor width adjustment (mm).
[Default] Proper data measurement result.
_ConvWidthMarkDiffX X
[Explanation] Sets the X-direction deviation (toward secondary rail mark) from
reference mark (mm).
[Default] Proper data measurement result.
_ConvMainArrvStopDis 20 or greater value O
[Explanation] Set the distance from the main conveyor arrival sensor to the stopper.
[Default] 20
_DLLRatio
[Explanation] Sets the automatically measured DLL ratio (if “0”, a setting of “0.63” is
adopted).
[Default] 0
_VT231LLRatio
[Explanation] Not used.
[Default] 0
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-51 XP-142E System Reference