1.2 OPERATION
_BrightLevelArrv –
[Explanation] Not used
[Default] 0
_TrayDetectMotion –
[Explanation] Not used.
[Default] 0
_GateMotionSwitch 0:1:2 O
[Explanation] Placement settings
0: Use sequence data settings
1: Arch motion
2: Gate motion
[Default] 0
_DisposeWaitTime –
[Explanation] Not used.
[Default] 0
_TrayAbsorbTime –
[Explanation] Not used.
[Default] 0
_DisposeConvSide –
[Explanation] Not used.
[Default] 0
_ResetCylORTime –
[Explanation] Not used.
[Default] 0
_PlaceDownEndTimer X
[Explanation] Sets the down limit timer at placing operation (msec).
[Default] 0
_DeviceSetChkUse 0:1:2:3 O
[Explanation] Specifies the part resupply confirmation method.
0: Automatic part resupply
1, 2: Manual part resupply
(Using the machine information screen for parts out or missed pick-
up)
3: Manual part resupply
(Using the machine information screen for parts out, missed pick-up,
or vision processing error)
[Default] 3
_ConvErrTime 0:60000 X
[Explanation] Sets the next stage arrival confirmation timer (msec).
0: 10000 (msec)
The value 1000 is used for all settings below 1000 (msec).
[Default] 0
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-4 XP-142E System Reference

_ConveyerMode 0:1:2 O
[Explanation] Specifies the conveyor mode
0: Same setting as 1.
1: Standard
(Acquire after main conveyor’s panel pass sensor switches on.)
2: Special (Acquire after unloading)
[Default] 1
_ConveyerPassMode 0:1 O
[Explanation] Specifies the conveyor pass mode
0: Normal pass mode (Clamped on main lifter)
1: No clamp mode (Not clamped on main lifter)
[Default] 0
_PickUpTimerSide1 –
[Explanation] Not used
[Default] 0
_PickUpTimerSide2 –
[Explanation] Not used.
[Default] 0
_PickVaccumStartTime –
[Explanation] Not used.
[Default] 0
_VacuumDesTime –
[Explanation] Not used.
[Default] 0
_VT130ImageProcTwice –
[Explanation] Not used.
[Default] 0
_TrayEjectCheck –
[Explanation] Not used.
[Default] 0
_DesStartTime –
[Explanation] Not used.
[Default] 0
_MultiImageNotDisp –
[Explanation] Not used.
[Default] 0
_ConvMtrSpeed X
[Explanation] Sets the panel conveyance speed (mm/sec)
[Default] 340 (“340” is also adopted if the setting is “0”)
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-5 XP-142E System Reference

_BlackMaskLevel -1 ~ 255 X
[Explanation] Sets the noise eliminating level when vision processing parts.
Recognizes brightness levels lower than that specified for part image
processing as being the same brightness, and eliminates noise.
-1: Automatic setting
[Default] -1
_PCFtpUse 0:1 O
[Explanation] Specifies the remote file
0: Disabled
1: Enabled
[Default] 0
_TemplateFind 1:2:3 O
[Explanation] Specifies the conditions for Vision Type 18 template file name search.
0,1: Part No. priority
2: Part type priority
3: Only part type is referenced
Note: Do not set to “0”.
[Default] 3
_MainLifterUpEndTimer O
[Explanation] Sets the waiting period (msec) for lifter UP motion. (Used when image
acquisition occurs before panel clamping is completed.)
[Default] 350
_FiducialLampOnTimer 0 ~ 1000 O
[Explanation] Sets the waiting period (msec) for lamp ON completion. (Used when
image acquisition occurs before the fiducial camera’s brightness has
stabilized.)
[Default] 0
_MainStArrvFDChkFlag –
[Explanation] Not used.
[Default] 0
_ThermalOffsetTime O
[Explanation] Sets the time interval between thermal expansion compensation
measurements when producing one panel. (msec)
Set “0” to disable thermal expansion compensation.
[Default] 0
_ThermalOffsetMark 0:1 O
[Explanation] Specifies the thermal offset reference marks
0: Fiducial marks
1: Position offset marks on the machine
[Default] 0
_NoNzlPosOffset –
[Explanation] Not used.
[Default] 0
_VcmBreakChkTime –
[Explanation] Not used.
[Default] 0
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-6 XP-142E System Reference