XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第288页

Part 8 Errors and Countermeasures (ESR09AA) This chapter provides a list of the error codes that appear on the scr een when a machine error occurs, along with measures that can be taken to correct the err or . 1. Error C…

100%1 / 344
Address Display Description
Y020
Y021
Y022 GaugeChipVacuum Gauge chip vacuum
Y023
Y024 PcbRequest Panel request to previous machine
Y025 PcbAvailable Panel unloading enabled signal to next machine
Y026 FollowPermit Follow permit output
Y027
Y028 MainStLifterUp MAIN station UP
Y029 MainStLifterDown MAIN station DOWN
Y02A MainStationStp MAIN station stopper on
Y02B
Y02C
Y02D InStLifterUp IN station lifter UP
Y02E ConvMtrDec Conveyor motor deceleration command
Y02F Conv/WidthMtr Conveyor/Width change motor
Y030
Y031
Y032
Y033
Y034 Fluores.LampOn Fluorescent lamp on
Y035 ChgConv/Width Conveyor width change
Y036 ChgCw/Ccw Change motor direction
Y037 PcbVacuum Panel pick-up vacuum
Y038 Side1MfuDown MFU DOWN (Side 1)
Y039 Side1MfuUp MFU UP (Side 1)
Y03A Side1TapeCutFwd Tape cut forward (Side 1)
Y03B Side1TapeCutBwd Tape cut backward (Side 1)
Y03C Side2MfuDown MFU DOWN (Side 2)
Y03D Side2MfuUp MFU UP (Side 2)
Y03E Side2TapeCutFwd Tape cut forward (Side 2)
Y03F Side2TapeCutBwd Tape cut backward (Side 2)
Part 7 Chapter 2 System Output Signals
Edition 2.0 7-2-2 XP-142E System Reference
Part 8
Errors and
Countermeasures
(ESR09AA)
This chapter provides a list of the
error codes that appear on the screen
when a machine error occurs, along
with measures that can be taken to
correct the error.
1. Error Code Messages and Corrective Measures
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-1-1
2. Corrective Measures for Error Messages that
Appear without an Error Code . . . . . . . . . .8-2-1
3. Corrective Measures for Problems at the
Machine
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-3-1
1. Error Code Messages and Corrective Measures
(ESR0901)
The following is a list of the error messages that appear with error codes.
If an error message appears without a code (number), refer to Section 2, “Corrective Measures
for Error Messages that Appear without an Error Code”.
All error codes are 8 characters in length (Ex. 1101B000, 1101B001)
The error codes are listed in ascending order of code number.
Code: 1101B000
Display: [***] is a range error.
Cause: A value which exceeds the permissible input range was entered.
Remedy: Enter a value within the permissible input range.
Code: 1101B001
Display: [***] is not defined.
Cause: If the set items are values, enter 0, if they are characters leave the fields blank.
Remedy: Input valid values.
Code: 1101C700
Display: Feeder skip settings of “0” and “1” have both been specified in the sequence data
for the same stage and slot number.
Cause: Sequence data with and without feeder skip settings exist for the same stage/slot
number.
Remedy: Correct the sequence data so that all sequences for the same stage/slot number
have the same feeder skip settings.
Code: 1101C701
Display: If a joint mode is not specified, stage 2 cannot be set in the sequence.
Cause: If a joint mode is not specified, stage 2 cannot be set in the sequence.
Remedy: Either skip all of the sequence data specified in stage 2, or delete stage 2.
Code: 1101C702
Display: Sequence Data (D) does not exist.
Cause: There is not a placement sequence in Sequence Data (Type D).
Remedy: When operating the machine without a placement sequence, set the pass mode in
panel data to “1: Pass”.
Code: 1101C703
Display: “Position X” exceeds the range of the panel.
Cause: The sequence data”s X-coordinate is off the panel.
Remedy: Specify an X-coordinate which is within the panel size range.
Code: 1101C704
Display: “Position Y” exceeds the range of the panel.
Cause: The sequence data”s Y-coordinate is off the panel.
Remedy: Specify an Y-coordinate which is within the panel size range.
Code: 1101C705
Display: There are sequences on the same board with the same mark number.
Cause: A fiducial mark reading sequence exists which has duplicate mark numbers
within a single board.
Remedy: Revise either the “Board No.” or “Mark No.” in the sequence data.
Part 8 Chapter 1 Error Codes and Corrective Measures
Edition 2.0 8-1-1 XP-142E System Reference