T_PlusLimit – [Explanation] Not used. [Default] 0 T_MinusLimit – [Explanation] Not used. [Default] 0 U_PlusLimit – [Explanation] Not used. [Default] 0 U_MinusLimit – [Explanation] Not used. [Default] 0 1.16 JOG_BASE_SPEE…

100%1 / 344
1.15 SERVO_LIMIT
X_PlusLimit XR
[Explanation] Sets the permissible servo X-axis plus-direction travel range (mm).
The machine must be restarted in order to register this setting.
[Default] Proper data measurement result.
X_MinusLimit XR
[Explanation] Sets the permissible servo X-axis minus-direction travel range (mm).
The machine must be restarted in order to register this setting.
[Default] 0
Y_PlusLimit XR
[Explanation] Sets the permissible servo Y-axis plus-direction travel range (mm).
The machine must be restarted in order to register this setting.
[Default] Proper data measurement result.
Y_MinusLimit XR
[Explanation] Sets the permissible servo Y-axis minus-direction travel range (mm).
The machine must be restarted in order to register this setting.
[Default] 0
Z_PlusLimit XR
[Explanation] Sets the permissible servo Z-axis plus-direction travel range (mm).
The machine must be restarted in order to register this setting.
[Default] Proper data measurement result.
Z_MinusLimit XR
[Explanation] Sets the permissible servo Z-axis minus-direction travel range (mm).
The machine must be restarted in order to register this setting.
[Default] 0
F_PlusLimit XR
[Explanation] Sets the permissible XP-142E servo F-axis plus-direction travel range
(mm). The machine must be restarted in order to register this setting.
[Default] Proper data measurement result.
F_MinusLimit XR
[Explanation] Sets the permissible XP-142E servo F-axis minus-direction travel range
(mm). The machine must be restarted in order to register this setting.
[Default] Proper data measurement result.
G_PlusLimit XR
[Explanation] Sets the permissible XP-142E servo G-axis plus-direction travel range
(mm). The machine must be restarted in order to register this setting.
[Default] Proper data measurement result.
G_MinusLimit XR
[Explanation] Sets the permissible XP-142E servo G-axis minus-direction travel range
(mm). The machine must be restarted in order to register this setting.
[Default] Proper data measurement result.
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-19 XP-142E System Reference
T_PlusLimit
[Explanation] Not used.
[Default] 0
T_MinusLimit
[Explanation] Not used.
[Default] 0
U_PlusLimit
[Explanation] Not used.
[Default] 0
U_MinusLimit
[Explanation] Not used.
[Default] 0
1.16 JOG_BASE_SPEED
X_jogBaseSpeed X
[Explanation] Minimum X-axis inching speed setting.
[Default] 10000
Y_jogBaseSpeed X
[Explanation] Minimum Y-axis inching speed setting .
[Default] 10000
Z_jogBaseSpeed X
[Explanation] Minimum Z-axis inching speed setting.
[Default] 2000
Q_jogBaseSpeed X
[Explanation] Minimum Q-axis inching speed setting
[Default] 50000
R_jogBaseSpeed X
[Explanation] Minimum R-axis inching speed setting for XP-142E.
[Default] 50000
F_jogBaseSpeed X
[Explanation] Minimum F-axis inching speed setting for XP-142E.
[Default] 10000
G_jogBaseSpeed X
[Explanation] Minimum G-axis inching speed setting for XP-142E.
[Default] 10000
T_jogBaseSpeed
[Explanation] Not used.
[Default] 10000
U_jogBaseSpeed
[Explanation] Not used.
[Default] 10000
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-20 XP-142E System Reference
1.17 SERVO_PARAMETER
x_MaxV X
[Explanation] Sets the maximum X-axis speed.
[Default] 16000000
x_MaxA X
[Explanation] Sets the maximum X-axis acceleration.
[Default] 240000000
x_ptpGain X
[Explanation] Sets the gain during X-axis travel.
[Default] 80
x_stGain X
[Explanation] Sets the gain during X-axis positioning.
[Default] 80
x_afterGain X
[Explanation] Sets the gain during X-axis stop.
[Default] 60
x_P_CON_Start X
[Explanation] Sets the X-axis P_CON start time (msec).
[Default] 6
x_integralGain X
[Explanation] Sets the X-axis integral gain.
[Default] 60
x_AxisValid
[Explanation] Not used.
[Default] 1
x_spare2
[Explanation] Not used.
[Default] 1
x_CurveNo X
[Explanation] Specifies the X-axis cam curve number.
[Default] 1
y_MaxV X
[Explanation] Sets the maximum Y-axis speed.
[Default] 25000000
y_MaxA X
[Explanation] Sets the maximum Y-axis acceleration.
[Default] 372000000
y_ptpGain X
[Explanation] Sets the gain during Y-axis travel.
[Default] 130
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-21 XP-142E System Reference