XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第322页

Code: 12100084 Display: Element leads are more than the specified value Cause: Element leads are more than the specified value Remedy: Replace the parts for which the error occurred or check the part data is correct. If …

100%1 / 344
Code: 12056038
Display: Nozzle size check error
An error occurred when performing nozzle size check by sensor.
Check that the machine nozzles match the nozzle settings in the data editor.
Check the operation of the nozzle size check sensor.
Cause: An error occurred when performing nozzle size check by sensor.
Remedy: Check that the machine nozzles match the nozzle settings in the data editor.
Check the operation of the nozzle size check sensor.
Code: 12056150
Display: Tray pallet is not retracted.
The elevator cannot be moved.
Confirm the tray pallet position.
Cause: The tray cannot be moved on the elevator because the tray retract confirmation
sensor is OFF.
Remedy: Correct the tray shuttle and tray pallet positions.
Check that the tray retract confirmation sensor is functioning correctly.
Code: 12056151
Display: The magazine tray check sensor turned off while the elevator was moving.
The elevator cannot be moved.
Confirm the tray pallet position.
Cause: The magazine tray check sensor turned off while the elevator was moving.
Remedy: Correct tray shuttle and tray pallet positions.
Check that the magazine tray check sensor is functioning correctly.
Code: 12100081
Display: Vision processing System Error
Cause: Vision processing System Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12100082
Display: Vision processing System Error
Cause: Vision processing System Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12100083
Display: Unable to detect leads.
Cause: Standard template error
Remedy: Check that the part data is correct; in particular, check the element data and the
“Stand Off” setting.
If the part data is correct, check the following possible causes:
*Poor pick-up performance
*Image brightness deterioration
*Poor camera focus
*Presence of dirt or other foreign object
Part 8 Chapter 1 Error Codes and Corrective Measures
Edition 2.0 8-1-33 XP-142E System Reference
Code: 12100084
Display: Element leads are more than the specified value
Cause: Element leads are more than the specified value
Remedy: Replace the parts for which the error occurred or check the part data is correct. If
the part data is correct, check the part pick-up condition is not incorrect. Check
the vision processing light brightness is functioning correctly, the focus is adjusted
correctly and the image is not dirty.
Code: 12100085
Display: Element leads are less than the specified value
Cause: Element leads are less than the specified value.
Remedy: Replace the parts for which the error occurred or check the part data is correct. If
the part data is correct, check the part pick-up condition is not incorrect. Check
the vision processing light brightness is functioning correctly, the focus is adjusted
correctly and the image is not dirty.
Code: 12100088
Display: Coplanarity tolerence error
Cause: The coplanarity check result shows the lead bent over the specified limit.
Remedy: Check the part lead is not bent or check the Coplanarity Tolerance specified in part
data is not too small.
Code: 12300301
Display: Socket transmission error
Cause: Unable to obtain a data communication port number at the IJ process or sub-
machine.
Remedy: Check the data communication port numbers for the IJ process and sub-machine
match.
Code: 12300302
Display: Socket transmission error
Cause: Unable to open the port because the designated port is not usable/in use.
Remedy: Check the communication port numbers for the IJ process and intermediate
machines match.
Code: 12300303
Display: Socket transmission error
Cause: The communication port number is invalid.
Remedy: Check that the communication port numbers for the IJ process and intermediate
machines match.
Code: 12300304
Display: Socket transmission error
Cause: Unable to obtain memory for socket communication.
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12300305
Display: Socket transmission error
Cause: The IP address is invalid.
Remedy: Check connecting terminal IP address of (IJ process or machine in the group).
Part 8 Chapter 1 Error Code Messages and Corrective Measures
Edition 2.0 8-1-34 XP-142E System Reference
Code: 12300306
Display: Socket transmission error
Cause: Socket transmission error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12300307
Display: Socket transmission error
Cause: Socket is invalid, or unable to connect or call machine.
Remedy: Check connecting terminal and status of machine.
Check main machine and connecting terminal network cables connections.
Code: 12300308
Display: Socket transmission error
Cause: The machine configurations are different on the IJ process side and machine side.
Remedy: Confirm machine configuration.
Code: 12300309
Display: Socket transmission error
Cause: The communication socket is invalid.
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 1230030A
Display: Socket transmission error
Cause: Unable to receive message
Remedy: Check status of connecting terminal and machine.
Check the machine and connecting terminal network cables connections.
Code: 1230030B
Display: Socket transmission error
Cause: Unable to receive message
Remedy: Check status of connecting terminal and machine.
Check the machine and connecting terminal network cables connections.
Code: 1230030C
Display: Socket transmission error
Cause: During automatic changeover, the user name for the FTP server that outputs the
production program is not valid.
Remedy: Check the FTP server user name.
Code: 1230030D
Display: Socket transmission error
Cause: During automatic changeover, the password for the FTP server that outputs the
production program is not valid.
Remedy: Check the FTP server password.
Code: 1230030E
Display: Socket transmission error
Cause: An invalid message was received.
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Part 8 Chapter 1 Error Codes and Corrective Measures
Edition 2.0 8-1-35 XP-142E System Reference