XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第325页
Code: 12300317 Display: Socket transmission error Cause: Socket communication time out. Remedy: Check the machine and connecting terminal network cables connections. Check the status of connecting terminal and machine. C…

Code: 1230030F
Display: Socket transmission error
Cause: A port that is already connected is selected as the communication port.
Remedy: Check the communication port numbers of the IJ process and intermediate
machines.
Code: 12300310
Display: Socket transmission error
Cause: Received an invalid command.
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12300311
Display: Socket transmission error
Cause: Received an invalid command.
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12300312
Display: Socket transmission error
Cause: Job data not specified.
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12300313
Display: Socket transmission error
Cause: Cannot locate connection socket.
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12300314
Display: Socket transmission error
Cause: Panel ID not specified.
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 12300315
Display: Socket transmission error
Cause: The machine number of the sub-machine used for automatic changeover is out of
range.
Remedy: Check the number of automatic changeover machines in the automatic changeover
settings.
Code: 12300316
Display: Socket transmission error
Cause: Unable to secure socket transmission memory.
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Part 8 Chapter 1 Error Code Messages and Corrective Measures
Edition 2.0 8-1-36 XP-142E System Reference

Code: 12300317
Display: Socket transmission error
Cause: Socket communication time out.
Remedy: Check the machine and connecting terminal network cables connections.
Check the status of connecting terminal and machine.
Code: 14011000
Display: Fiducial mark read error
Cause: Fiducial mark read error
Remedy: Check the correct mark data has been input. Confirm the program coordinates
and actual mark location correspond correctly. Check the mark is not dirty or
obstructed.
Code: 14011001
Display: Area check detected a value outside the permissible range
Cause: Area check detected a value outside the permissible range.
Remedy: Confirm the program coordinates and actual mark location correspond correctly.
The mark may have been read incorrectly.
Code: 14011002
Display: Pitch check detected a value outside the permissible range
Cause: Pitch check detected a value outside the permissible range.
Remedy: Confirm the program coordinates and actual mark location correspond correctly.
The mark may have been read incorrectly.
Code: 14011003
Display: Failed to read reference mark during cycle steal.
Cause: Failed to read reference mark during cycle steal.
Remedy: Check that the reference mark is clean.
Code: 14011004
Display: The reference mark deviation is more than 1mm. Re-measure the reference mark.
Cause: The calibration data value for the reference mark does not match the origin
position.
Remedy: Re-measure the reference mark and, if necessary, the origin position.
Code: 14011005
Display: Failed to acquire image of the reference mark.
Cause: Failed to acquire image of the reference mark.
Remedy: Check that the reference mark is not soiled, and check the reference mark
calibration data settings.
Code: 14011006
Display: A precise tray reference mark could not be found.
Cause: If the tray that was read is a precise tray, then either the mark is dirty or its
position is too far from the reference position.
If the tray is a reference tray, then the precise tray check sensor is out of
adjustment.
Remedy: For precise trays, check that the mark is clean.
Eliminate any play from the shuttle.
For standard trays, adjust the precise tray check sensor (X045).
Part 8 Chapter 1 Error Codes and Corrective Measures
Edition 2.0 8-1-37 XP-142E System Reference

Code: 1404D000
Display: Mechanical chuck part transportation error. If the mechanical chuck is holding the
part, manually remove it from the chuck.
Cause: Mechanical chuck part transportation error.
Remedy: If the mechanical chuck is holding the part, manually remove it from the chuck. If
the mark is dirty remove the mechanical chuck and clean the mark.
Code: 1404D001
Display: Compile error.
Cause: Vision processing Data Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 1404D003
Display: Nozzle vision processing failed during cycle steal
Cause: Nozzle vision processing failed during cycle steal.
Check nozzle for scratches or foreign matter.
Check light radiation of strobe light.
Code: 1404D005
Display: A foreign matter was detected on the nozzle surface. Check that all parts have
been placed on the panel.
Cause: A foreign matter was detected on the nozzle surface.
Remedy: Check nozzle surface for foreign matter.
Code: 1404D006
Display: Nozzle center could not be detected.
Cause: Nozzle center could not be detected.
Remedy: Check that the nozzle diameter is correct.
Check that the surface of the nozzle is not scratched or dirty.
Check that the strobe light is emitting light properly.
Code: 1404D007
Display: Nozzle size check error
An error occurred while performing nozzle size check by vision processing.
Check that the machine nozzles match the nozzle settings in the data editor.
Check nozzle for scratches or foreign matter.
Check light radiation of strobe light.
Cause: An error occurred while performing nozzle size check by vision processing.
Remedy: Check that the machine nozzles match the nozzle settings in the data editor.
Check nozzle for scratches or foreign matter.
Check light radiation of strobe light.
Part 8 Chapter 1 Error Code Messages and Corrective Measures
Edition 2.0 8-1-38 XP-142E System Reference