Code: 1D00500F Display: Element lead pitch error Cause: Element lead pitch error Remedy: Replace the parts for which the error occurred or check the part data is correct. If the part data is correct, check the part pick-…

100%1 / 344
Code: 1D00500B
Display: Repeated pattern matching of left leads
Cause: Lead detection failed.
Remedy: Replace the parts for which the error occurred or check the part data is correct. If
the part data is correct, check the part pick-up condition is not incorrect. Check
the vision processing light brightness is functioning correctly, the focus is adjusted
correctly and the image is not dirty.
When using multi-window processing check the image comparison. If the images
are different check the actual part height matches that in part data and the nozzle
holder is calibrated correctly.
Code: 1D00500C
Display: Repeated pattern matching of right leads
Cause: Lead detection failed.
Remedy: Replace the parts for which the error occurred or check the part data is correct. If
the part data is correct, check the part pick-up condition is not incorrect. Check
the vision processing light brightness is functioning correctly, the focus is adjusted
correctly and the image is not dirty.
When using multi-window processing check the image comparison. If the images
are different check the actual part height matches that in part data and the nozzle
holder is calibrated correctly.
Code: 1D00500D
Display: Element leads are less than the specified value
Cause: Element leads are more than the specified value.
Remedy: Replace the parts for which the error occurred or check the part data is correct. If
the part data is correct, check the part pick-up condition is not incorrect. Check
the vision processing light brightness is functioning correctly, the focus is adjusted
correctly and the image is not dirty.
When using multi-window processing check the image comparison. If the images
are different check the actual part height matches that in part data and the nozzle
holder is calibrated correctly.
Code: 1D00500E
Display: Element leads are more than the specified value
Cause: Element leads are more than the specified value.
Remedy: Replace the parts for which the error occurred or check the part data is correct. If
the part data is correct, check the part pick-up condition is not incorrect. Check
the vision processing light brightness is functioning correctly, the focus is adjusted
correctly and the image is not dirty.
When using multi-window processing check the image comparison. If the images
are different check the actual part height matches that in part data and the nozzle
holder is calibrated correctly.
Part 8 Chapter 1 Error Code Messages and Corrective Measures
Edition 2.0 8-1-44 XP-142E System Reference
Code: 1D00500F
Display: Element lead pitch error
Cause: Element lead pitch error
Remedy: Replace the parts for which the error occurred or check the part data is correct. If
the part data is correct, check the part pick-up condition is not incorrect. Check
the vision processing light brightness is functioning correctly, the focus is adjusted
correctly and the image is not dirty.
When using multi-window processing check the image comparison. If the images
are different check the actual part height matches that in part data and the nozzle
holder is calibrated correctly.
Code: 1D005010
Display: Bump size error
Cause: Bump size error
Remedy: Replace the parts for which the error occurred or check the part data is correct. If
the part data is correct, check the part pick-up condition is not incorrect. Check the
vision processing light brightness is functioning correctly, the focus is adjusted
correctly and the image is not dirty.
When using multi-window processing check the image comparison. If the images
are different check the actual part height matches that in part data and the nozzle
holder is calibrated correctly.
Code: 1D005011
Display: Element lead length error
Cause: Element lead length error
Remedy: Replace the parts for which the error occurred or check the part data is correct. If
the part data is correct, check the part pick-up condition is not incorrect. Check
the vision processing light brightness is functioning correctly, the focus is adjusted
correctly and the image is not dirty.
When using multi-window processing check the image comparison. If the images
are different check the actual part height matches that in part data and the nozzle
holder is calibrated correctly.
Code: 1D005012
Display: Element lead width error
Cause: Element lead width error
Remedy: Replace the parts for which the error occurred or check the part data is correct. If
the part data is correct, check the part pick-up condition is not incorrect. Check
the vision processing light brightness is functioning correctly, the focus is adjusted
correctly and the image is not dirty.
When using multi-window processing check the image comparison. If the images
are different check the actual part height matches that in part data and the nozzle
holder is calibrated correctly.
Part 8 Chapter 1 Error Codes and Corrective Measures
Edition 2.0 8-1-45 XP-142E System Reference
Code: 1D005013
Display: Element lead center error
Cause: Element lead center error
Remedy: Replace the parts for which the error occurred or check the part data is correct. If
the part data is correct, check the part pick-up condition is not incorrect. Check
the vision processing light brightness is functioning correctly, the focus is adjusted
correctly and the image is not dirty.
When using multi-window processing check the image comparison. If the images
are different check the actual part height matches that in part data and the nozzle
holder is calibrated correctly.
Code: 1D005014
Display: No parts
Cause: A “No part” error was detected for vision types 10, 20.
Remedy: Re-supply parts.
If parts are still being picked up, check the following possible causes:
• Poor pick-up performance
• Image brightness deterioration
• Poor camera focus
• Presence of dirt or other foreign object
Code: 1D005015
Display: Vision processing System Error
Cause: Vision processing System Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 1D005016
Display: Vision processing System Error
Cause: Vision processing System Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Part 8 Chapter 1 Error Code Messages and Corrective Measures
Edition 2.0 8-1-46 XP-142E System Reference