_PickPosMeasureOfstY2 O [Explanation] Set the difference (mm) between the pick-up compensation value from the mark camera and the actual pick-up compensation value, according to the pick-up position measurement function.…

X_CoplanarityPosX –
[Explanation] Not used.
[Default] 0
Y_CoplanarityPosY –
[Explanation] Not used.
[Default] 0
Z_CoplanarityPosZ –
[Explanation] Not used.
[Default] 0
_CoplaCamShutterSpeed –
[Explanation] Not used.
[Default] 0
_MarkAreaTolerance 0 ~ 10.00 O
[Explanation] Sets the permissible fiducial mark reading range (mm).
Used when the F-mark reading tolerance range is not specified in the
production program.
[Default] 0
_MarkPitchTolerance 0 ~ 10.00 O
[Explanation] Sets the permissible fiducial mark reading pitch (mm).
Used when the F-mark reading tolerance pitch is not specified in the
production program.
[Default] 0
_DesEndDistanceFromDownEnd –
[Explanation] Not used.
[Default] 0
_PickPosMeasureOfstX1 O
[Explanation] Set the difference (mm) between the pick-up compensation value from
the mark camera and the actual pick-up compensation value,
according to the pick-up position measurement function.
[Default] 0
_PickPosMeasureOfstY1 O
[Explanation] Set the difference (mm) between the pick-up compensation value from
the mark camera and the actual pick-up compensation value,
according to the pick-up position measurement function.
[Default] 0
_PickPosMeasureOfstX2 O
[Explanation] Set the difference (mm) between the pick-up compensation value from
the mark camera and the actual pick-up compensation value,
according to the pick-up position measurement function.
[Default] 0
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-52 XP-142E System Reference

_PickPosMeasureOfstY2 O
[Explanation] Set the difference (mm) between the pick-up compensation value from
the mark camera and the actual pick-up compensation value,
according to the pick-up position measurement function.
[Default] 0
_NzlSizeChkSpeed –
[Explanation] Notused.
[Default] 0
_NzlSizeChkLength –
[Explanation] Notused.
[Default] 0
_NzlSizeChkHeight –
[Explanation] Notused.
[Default] 0
_NzlSizeChkDepth –
[Explanation] Notused.
[Default] 0
_NzlSizeChkPosX –
[Explanation] Notused.
[Default] 0
_NzlSizeChkPosY –
[Explanation] Notused.
[Default] 0
_NzlSizeChkPosZ –
[Explanation] Notused.
[Default] 0
_MechaChuckClampTimer –
[Explanation] Notused.
[Default] 0
_MechaChuckUnclampTimer –
[Explanation] Notused.
[Default] 0
_MechaChuckSafeguard –
[Explanation] Notused.
[Default] 0
_MechaChuckMarkDiameter –
[Explanation] Notused.
[Default] 0
_FiducialLampSetting –
[Explanation] Notused.
[Default] 0
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-53 XP-142E System Reference

_MinimumConveyorWidth 0 ~ 49.99 X
[Explanation] This setting is only for custom machines for panels 50mm or less in the
Y-direction. (Entry is possible only on modified machines.)
[Default] 0
_MaximumPanelSizeX 0 ~ 79.99 O
[Explanation] This is for machines for panels 80mm or less in the X-direction.
[Default] 0
Part 6 Chapter 1 Proper Data Measurement