XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第330页
Code: 1D005001 Display: Vision processing System Error Cause: Vision processing System Error Remedy: Internal error. This error should not occur under normal circumstances. Take a machine trace and send it to your Fuji r…

Code: 1503100F
Display: Failed to check out a panel at the main pass sensor
Cause: Unable to confirm the panel position.
Remedy: Check the panel is not stuck on the conveyor, and check the main pass sensor is
operating correctly.
Code: 15031010
Display: Failed to convey a panel to next machine.
Cause: Unable to convey the panel to the next machine.
Remedy: Check the panel is not stuck inside the machine, and check the signal from the next
machine.
Code: 15031011
Display: Failed to convey a panel to the main station deceleration sensor
Cause: Unable to convey a panel to the main station deceleration sensor.
Remedy: Check the panel is not stuck on the conveyor, and the main station deceleration
sensor is functioning correctly.
Code: 15031012
Display: Failed to convey a panel in the in station interval.
Cause: Failed to convey a panel in the in station interval.
Remedy: Check that the panel available signal from the previous machine
(X018:PcbAvailable) is operating correctly.
Code: 15032010
Display: Production cannot be started. A panel is detected by the Main Station speed
reduction/arrival/pass sensor, but stopper is not up.
Cause: Production cannot be started. A panel is detected by the Main Station speed
reduction/arrival/pass sensor, but stopper is not up.
Remedy: Raise the stopper using the commands at the Conveyor Operation screen, then
start the machine.
If there is no panel and this error still displays, check the Main Station speed
reduction/arrival/pass sensor.
Code: 15032011
Display: Unable to determine the status of the panel at the Out pass sensor.
Cause: The panel has not been detected by the panel pass confirmation sensor.
Remedy: Check the panel is not stuck on the conveyor.
If the panel is not on the conveyor check that the panel pass confirmation sensor is
functioning correctly.
Code: 15032012
Display: Out station panel cannot be ejected because there is no panel request signal.
Cause: Out station panel cannot be ejected because there is no panel request signal.
Remedy: Start the machine while the next machine panel request signal is ON.
Remove the panel from the OUT station, then start the machine.
If there is no panel and this error still displays, check the Main Station speed
reduction/arrival/pass sensor.
Part 8 Chapter 1 Error Codes and Corrective Measures
Edition 2.0 8-1-41 XP-142E System Reference

Code: 1D005001
Display: Vision processing System Error
Cause: Vision processing System Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 1D005002
Display: Vision processing System Error
Cause: Vision processing System Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 1D005003
Display: Vision processing System Error
Cause: Vision processing System Error
Remedy: Internal error. This error should not occur under normal circumstances. Take a
machine trace and send it to your Fuji representative.
Code: 1D005004
Display: Pattern matching error
Cause: Unable to perform pattern matching.
Remedy: Replace the parts for which the error occurred or check the part data and the
template are correct.
If the part data and template data is correct, check the part pick-up condition is not
incorrect, the vision processing light brightness is functioning correctly, the focus
is adjusted correctly and the image is not dirty.
When using multi-window processing check the image comparison. If the images
are different check the actual part height matches that in part data and the nozzle
holder is calibrated correctly. (XP241, XP341)
Code: 1D005005
Display: X-direction size error
Cause: Patter matching was successful, however the X-side body size is over the
permissible value (Part data Body Length Tolerance).
Remedy: Confirm the part was picked up correctly, and the Body Length Tolerance value is
not too small. Either exchange the erroneous part or correct the part data. If the
part data is correct, check the pickup position, the vision processing brightness,
the focus and the cleanliness of the lens.
When using multi-window processing check the image comparison. If the images
are different check the actual part height matches that in part data and the nozzle
holder is calibrated correctly. (XP241, XP341)
Part 8 Chapter 1 Error Code Messages and Corrective Measures
Edition 2.0 8-1-42 XP-142E System Reference

Code: 1D005006
Display: Y-direction size error
Cause: Patter matching was successful, however the Y-side body size is over the
permissible value (Part data Body Length Tolerance).
Remedy: Confirm the part was picked up correctly and the Body Length Tolerance value is
not too small. Either exchange the erroneous part or correct the part data. If the
part data is correct, check the pickup position, the vision processing brightness,
the focus and the cleanliness of the lens.
When using multi-window processing check the image comparison. If the images
are different check the actual part height matches that in part data and the nozzle
holder is calibrated correctly. (XP241, XP341)
Code: 1D005007
Display: Inspection seek line error
Cause: Inspection seek line error
Remedy: Replace the parts for which the error occurred or check the part data as well as the
template are correct.
If the part data and template data is correct, check the part pick-up condition is not
incorrect. Check the vision processing light brightness is functioning correctly, the
focus is adjusted correctly and the image is not dirty.
When using multi-window processing check the image comparison. If the images
are different check the actual part height matches that in part data and the nozzle
holder is calibrated correctly. (XP241, XP341)
Code: 1D005008
Display: Vision processing System Error
Cause: Vision processing System Error
Remedy: Internal error.
This error should not occur under normal circumstances.
Take a machine trace and send it to your Fuji representative.
Code: 1D005009
Display: Unable to detect leads.
Cause: The element information does not match the part.
Remedy: Check the part data is correct.
If the part data is correct, check the part pick-up condition is not incorrect.
Check the vision processing light brightness is functioning correctly, the focus is
When using multi-window processing check the image comparison.
If the images are different check the actual part height matches that in part data
and the nozzle holder is calibrated correctly.
Code: 1D00500A
Display: Element lead pattern matching error
Cause: The element information does not match the part.
Remedy: If the part data is correct, check the part pick-up condition is not incorrect. Check
the vision processing light brightness is functioning correctly, the focus is adjusted
correctly and the image is not dirty.
When using multi-window processing check the image comparison. If the images
are different check the actual part height matches that in part data and the nozzle
holder is calibrated correctly.
Part 8 Chapter 1 Error Codes and Corrective Measures
Edition 2.0 8-1-43 XP-142E System Reference