XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第67页
3.6 Supply of T ape Parts (ESR0221e) The MFU is clamped to, and unclamped from, the machine by an air cylinder driven mechanism. The Side 1 procedure is explained below, but the procedure is identical for Side 2. Note: T…

Part 2 Chapter 3 Changeover
Edition 2.0 2-3-12 XP-142E System Reference
3.5.3 Nozzle Center Measurement
Nozzle center measurements occur using the parts camera to perform vision processing
on a gauge chip part to determine the nozzle holder’s rotation center.
The vector between the rotation center and the mark camera center is measured.
(This measurement can be performed for standard (ø0.4 ~ ø5.0 nozzles.)
Procedure
1. At the [Main] screen, press [Production] then [Nozzle Center Measurement] to
display the screen shown below.
2. Select the Side where the measurement is to occur, then press the [Start rotation
measurement] button. Measurement occurs using the machine’s front camera if
Side 1 was selected, and the rear camera if Side 2 was selected.
Select the appropriate jig (3 types) according to the size of the mounted nozzle
(displays at the [Jig Type] area). The vector between the revolver (R-axis) and the
mark camera center is measured.
3. When the rotation center measurement is completed, press the [Nozzle center
measurement] button. This measurement is performed by the same camera which
performed the rotation center measurement.
Note: As measurements are performed for each nozzle, all the nozzles should be
mounted.

3.6 Supply of Tape Parts
(ESR0221e)
The MFU is clamped to, and unclamped from, the machine by an air cylinder driven
mechanism. The Side 1 procedure is explained below, but the procedure is identical for
Side 2.
Note: This function is disabled on machines equipped with a fixed device table.
3.6.1 Changing an MFU
Clamping Procedure
1. Open the machine’s front door, then gently push the MFU into its machine
docking position.
2. At the [Main] screen, press [Manual Operation], then [STAGE1 MFU Clamp] to
display a start confirmation dialog box. Press the START switch to clamp the
MFU.
Unclamping Procedure
1. From the [Main] screen, select [Machine Operation] - [STAGE1 MFU Unclamp].
A “START confirmation” dialog box then displays.
2. Press [START] to unclamp the machine’s front-side MFU.
The following message then displays: “Work after the door of the front is opened.”
3. Open the door at the side where the MFU was unclamped, then press [OK] on the
display screen.
4. Gently pull the MFU out of the machine.
Note: Only the MFU on the side of the machine that is enabled can be removed.
3.6.2 Tape Cutter Manual Operation
1. At the [Main] screen, select [Manual Operation], then [Tape Cutter Stage1].
A confirmation dialog is displayed.
2. Push the START button to cut the feeder tape on Side 1 of the machine.
Note: This command is restricted to the control panel on the same side of the machine as
the tape cutter to be activated.
Part 2 Chapter 3 Changeover
Edition 2.0 2-3-13 XP-142E System Reference

3.6.3 [Feeder Data Info] Screen
(ESR0207h)
This screen is used to verify device types and slot positions used in production, and to
check for parts-out errors.
Procedure
1. At the [Main] screen, press [Production] then [Feeder Data Info] to display the
[Feeder Data] screen.
2. Each screen contains boxes that indicate the status of 20 feeders on the MFU. From
left to right are the slot number, the part status, and a comment area.
• The Stage and Slot numbers are displayed with the following color codes.
Red: Original slot
Blue: Next slot
Black: Unused slot
• When a part runs out, an [X] is displayed. After loading more parts, push the [X]
to return the status to normal [O].
Part 2 Chapter 3 Changeover