XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第84页

5.3 Mark Editing Function (ESR0240c) 5.3.1 Mark Editing Function Overview If a fiducial mark error occurs during automatic operation, mark reading support allows you to show the machine where the center of the mark is. G…

100%1 / 344
5. Stopping and Resuming Production
5.1 Cycle Stop and Resuming Production
(ESR0210a)
Press the CYCLE STOP button.
The machine stops at the end of the current cycle. Pressing CYCLE STOP does not
cut the 200V power.
Push START to resume operation.
5.2 Adding Parts When a Slot Runs Out of Parts
(ESR0259a)
If a [Parts shortage] or [Vision error] occurs during automatic production, then the [Error
info.] screen is displayed. After the error information screen is closed, then parts can be
added to the slot that is out of parts (perform device check) and automatic production
restarted.
To perform device check, at the screen displayed during production, select [Set
complete], then [Set all] to reset the parts set status.
The conditions required for device check can be specified in the Proper data item
_DeviceSetChkUse.
0: Device check is not performed. When the error screen is closed all slots are
automatically returned to parts set status.
1, 2: Device check is performed for the slot where the parts shortage or pickup miss
occurred. If a vision error occurred then the slot is automatically returned to
the parts set status.
3: Device check is performed for the slot where the parts shortage, pickup miss, or
vision error occurred.
Part 2 Chapter 5 Stopping and Resuming Production
Edition 2.0 2-5-1 XP-142E System Reference
5.3 Mark Editing Function
(ESR0240c)
5.3.1 Mark Editing Function Overview
If a fiducial mark error occurs during automatic operation, mark reading support allows
you to show the machine where the center of the mark is.
Guidance lines display at the machine monitor that can be positioned using the mouse to
adjust the center coordinates of the mark. This adjustment is only possible when the
mark appears within the image shown at the screen. There may be a slight misalignment
of one pixel (approx. 16 µm) since the finest unit of adjustment is a pixel.
5.3.2 Mark Editing Function Screen
(1) Error Information Screen
When a fiducial mark read error occurs, press [Error info] to display the error
information screen. Press [Close] to display the mark editor screen.
Part 2 Chapter 5 Stopping and Resuming Production
Edition 2.0 2-5-2 XP-142E System Reference
Part 2 Chapter 5 Stopping and Resuming Production
Edition 2.0 2-5-3 XP-142E System Reference
(2) Mark Editing Screen
The components of the mark editing screen are as follows.
Display:
Buttons:
*: The reset caliper widths are the previously measured values.
Center Set
Reset Press to reset* the position of the caliper lines, and the values at [Calipers],
[Center] and [Offset].
+, - Press the [+] and [-] buttons to adjust the values in increments of 0.01. Keep
the buttons pressed down to consecutively increase the values. Adjusting
these values moves the associated calipers on the screen.
Cancel Press to close the mark editor screen without saving the caliper measurement
data.
Press to set the measured offset and continue production.
XP1S2147E
Mark image
Calipers Indicates the width of the calipers. Units are in millimeters.
Center Indicates the center coordinates measured from the position of the calipers.
Units are in millimeters.
Offset Indicates the difference between the existing coordinates and measured
mark center position. Units are in millimeters.
Adjust the green (caliper width X), blue (caliper width Y) and the red (mark
center position) lines offset the current mark position setting. The [Calipers]
and [Center] buttons can also be used to adjust the lines.
XP1S2146Ea