XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第95页

Operation Button Explanations Proceeds to the panel information screen. Proceeds to the machine status information screen. Proceeds to the feeder information screen. Proceeds to the nozzle information screen. Proceeds to…

100%1 / 344
6.2.2 Production Information Display Conditions Setting Screen
Data Explanation
This screen can be used to specify the time frame for the development of production
information, and to select programs. Click the [X] button to enable a time frame (the
button indicator changes to [O]). If no time frame is to be set, click the button again to
change the button indicator to [X].
The names of production programs are obtained from a log file stored in the
current/sd0FUJI/USER/PRODUCT folder, and display in the window shown above.
From this list, select the name of the program which contains the information to be
displayed.
When a program is selected, the program operation time for the unselected programs
becomes "power off time". To make selections in log file units, click [Log File] to change
to the Log File selection screen.
Part 2 Chapter 6 Production Information Display
Edition 2.0 2-6-4 XP-142E System Reference
Operation Button Explanations
Proceeds to the panel information screen.
Proceeds to the machine status information screen.
Proceeds to the feeder information screen.
Proceeds to the nozzle information screen.
Proceeds to the error information screen.
Develops the production information in accordance with the
currently specified conditions, and saves it to a floppy disk.
Although the default file name for the saved data is "PRODINFO",
the name be changed at the dialog box shown below.
Proceeds to the log file selection screen.
Part 2 Chapter 6 Production Information Display
Edition 2.0 2-6-5 XP-142E System Reference
Displays the dialog box shown below.
The log file save conditions (automatically deleted) can be set at
this dialog box. The [O] and [X] buttons at the left enable and
disable the conditions settings which are specified by the numeric
values on the right.
Note: Even if these settings are changed, unnecessary log files will not
be deleted. Delete them manually from the log file selection
screen.
Save Period (Days): Specifies the number of days a log file is to
be saved. When a files "saved period"
reaches this value, the file is automatically
deleted.
Save Size: Specifies the total size of saved log files.
When this total size is exceeded, log files are
deleted, beginning from the oldest, until the
total size is less than the "Save Size" value.
However, log files which have been saved
for less than the "Save Period" are not
deleted. However, log files with the current
date will not be deleted even if the total log
file memory size exceeds the [Size] limit.
Returns to the main menu screen.
Part 2 Chapter 6 Production Information Display
Edition 2.0 2-6-6 XP-142E System Reference