XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第54页

Notes: Part 2 Chapter 2 Settings Prior to Start Production Edition 2.0 2-2-12 XP-142E System Reference

100%1 / 344
2.2 Signal Tower Settings
(ESR0224b)
Signal tower lamp ON / BLINKING settings can be specified from the machine menu.
Procedure
1. At the [Main] screen, press [Maintenance B] then [Signal Tower] to display the
[Signal Tower] screen.
2. Specify the signal tower color, lamp status (on/blinking), and buzzer, etc., settings
for each item. “O” marks indicate the specified settings.
3. After verifying that the settings are correct, press [Close] to end the setting
operation.
Note: Item 14: “Stage Change Alarm” is option.
Part 2 Chapter 2 Settings Prior to Start Production
Edition 2.0 2-2-11 XP-142E System Reference
Notes:
Part 2 Chapter 2 Settings Prior to Start Production
Edition 2.0 2-2-12 XP-142E System Reference
3. Changeover
3.1 Selecting a Production Program
(ESR0202i)
Production programs can be stored at the CPU board, on the machine’s hard disk, on a
floppy disk, or at the host computer. In order to use a stored program in production, an
“active” status (at CPU board memory) must be specified for that program. The name of
the program which is currently active displays on the task bar at the top of the screen.
3.1.1 Selecting a Production Program From the [Production]
Screen
Procedure
1. At the [Main] screen, press [Production] then [Program Select] to display a dialog
box showing a list of programs which are stored in the machine’s hard disk or on a
floppy disk.
Note: CCIMF format files created for FCP6(M), CP642(M), CP643(M), and XP-141E / XP-
142E machines can be read from a floppy disk. Because the XP-142E has only two
MFU units (100 slots / 8 mm tape width conversion), feeder setup data which
exceeds this capacity must not be used.
2. Select the desired production program from the list, then press the [Download]
button to load that program. The name of the loaded program displays on the
taskbar at the top of the screen, indicating that this program is now active.
Part 2 Chapter 3 Changeover
Edition 2.0 2-3-1 XP-142E System Reference