1.4 OPERA TION_2 _DoNozzleCleaning 0:1 O [Explanation] Set whether nozzle cleaning is used or not. 0: Not used 1: Used [Default] 1 _PolarityConvert 0:1 OR [Explanation] Specifies the polarity converter start. 0: Start 1:…

100%1 / 344
Q_StbTimeFast X
[Explanation] Sets the time (msec) for the Q-axis to stabilize when in fast mode.
[Default] Proper data measurement result.
X_StbTimeSlow X
[Explanation] Sets the time (msec) for the X-axis to stabilize when in slow mode.
[Default] Proper data measurement result.
Y_StbTimeSlow X
[Explanation] Sets the time (msec) for the Y-axis to stabilize when in slow mode.
[Default] Proper data measurement result.
R_StbTimeSlow X
[Explanation] Sets the time (msec) for the R-axis to stabilize when in slow mode.
[Default] Proper data measurement result.
Q_StbTimeSlow X
[Explanation] Sets the time (msec) for theQ-axis to stabilize when in slow mode.
[Default] Proper data measurement result.
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-8 XP-142E System Reference
1.4 OPERATION_2
_DoNozzleCleaning 0:1 O
[Explanation] Set whether nozzle cleaning is used or not.
0: Not used
1: Used
[Default] 1
_PolarityConvert 0:1 OR
[Explanation] Specifies the polarity converter start.
0: Start
1: Do not start
Note: Do not set to “0”.
[Default] 1
_DChangeTriger 0:1:2:3 O
[Explanation] Specifies the slot / stage change trigger.
0: Move to the next slot after a parts out or vision processing error.
1, 2: Move to the next slot after a parts out error. Machine stops if
vision processing error occurs.
3: Refers to the Alt. Feeder Trigger setting in part data, to move to
the next slot or stop the machine.
[Default] 0
_ResetNGPartTrayUncondition 0:1 O
[Explanation] Specifies whether or not to confirm opening and closing of the door
after the NG part tray fills up.
0: Confirm
1: Do not confirm
[Default] 0
_NotSimpleOptimize
[Explanation] Not used.
[Default] 0
_NozzleSufrfaceCheck 0:1 O
[Explanation] Enables/disables the function which checks for foreign matter
adhering to nozzles.
0: Not used
1: Used
[Default] 0
_UseVisionHeightOffset
[Explanation] Not used.
[Default] 0
_FrontSideShtSpd
[Explanation] Not used.
[Default] 0
_FrontFrontShtSpd
[Explanation] Not used.
[Default] 0
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-9 XP-142E System Reference
_RearSideShtSpd
[Explanation] Not used.
[Default] 0
_RearFrontShtSpd
[Explanation] Not used.
[Default] 0
_PlacingModeSwitch 0 ~ 2 O
[Explanation] Set the double motion changeover at the placement.
0: Single motion
1: Double motion (Fine Slow & Fine Fast)
2: Double motion (All)
[Default] 0
_JogInterlockOFF 0:1 X
[Explanation] Set whether the jog interlock is used or not.
0: Enabled
1: Disabled
[Default] 0
_PickPosAutoMeasure 0:1:2 O
[Explanation] Set whether automatic placement position measurement is used or not.
0: Disabled
1: Placement position measurement is executed using the commands at
the screen.
2: Placement position measurement is executed automatically during
production, or using the commands at the screen.
[Default] 0
_UseMachineNozzleOnly 0:1 O
[Explanation] Set whether the nozzles loaded on the machine are used in the data
check carried out during operation preparations.
0: Not used
1: Used
[Default] 0
_MiniSigWhiteLighting 0:1 O
[Explanation] Specifies the lighting conditions for the operation display.
0: XP original
1: Fuji standard
[Default] 0
_VcmBreakChkSensor
[Explanation] Not used.
[Default] 0
_NzlSizeChkFlag
[Explanation] Not used.
[Default] 0
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-10 XP-142E System Reference