XP-142E System Reference-SYS-XP142-2.0E.pdf.pdf - 第259页
G_DownPoint X [Explanation] Sets the G-axis DOWN limit (counter value). [Default] Proper data measurement result. R_Pos1 X [Explanation] Sets the revolver angle when nozzle 1 is at pickup position. [Default] 0 Q_PosPick1…

_DevPitch1 16:20 X
[Explanation] Specifies the device pitch (Stage 1).
16:16 (mm) pitch.
20:20 (mm) pitch
[Default] 16
_DevPitch2 16:20 X
[Explanation] Specifies the device pitch (Stage 2).
16:16 (mm) pitch
20:20 (mm) pitch
[Default] 16
_DevPitch3 –
[Explanation] Not used.
[Default] 0
_DevPitch4 –
[Explanation] Not used.
[Default] 0
X_BoardOrg X
[Explanation] Sets the panel origin X (counter value).
[Default] Proper data measurement result.
Y_BoardOrg X
[Explanation] Panel origin Y (counter value).
[Default] Proper data measurement result.
Z_BoardSurface X
[Explanation] Sets the panel surface height (counter value).
[Default] Proper data measurement result.
X_TableOrg X
[Explanation] Specifies the X-axis counter value at head retract position.
[Default] 5
Y_TableOrg X
[Explanation] Specifies the Y-axis counter value at head retract position.
[Default] 400
F_UpPoint X
[Explanation] Sets the F-axis UP limit (counter value).
[Default] Proper data measurement result.
F_DownPoint X
[Explanation] Sets the F-axis DOWN limit (counter value).
[Default] Proper data measurement result.
G_UpPoint X
[Explanation] Sets the G-axis UP limit (counter value).
[Default] Proper data measurement result.
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-32 XP-142E System Reference

G_DownPoint X
[Explanation] Sets the G-axis DOWN limit (counter value).
[Default] Proper data measurement result.
R_Pos1 X
[Explanation] Sets the revolver angle when nozzle 1 is at pickup position.
[Default] 0
Q_PosPick1 X
[Explanation] Sets the Q-axis pickup position when nozzle 1 is at pickup position.
[Default] 6.5
Q_PosPlace1 X
[Explanation] Sets the Q-axis placing position when nozzle 1 is at “R_POS1”
position.
[Default] 0
Z_DoubleMotionPoint X
[Explanation] This is the height (mm) where the Z-axis pauses when performing
Z-axis double motion during placement.
[Default] Proper data measurement result.
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-33 XP-142E System Reference

1.20 NOZZLE_POSITION
X_NzlPosX1 –
[Explanation] Not used.
[Default] 0 (This setting is ignored.)
Y_NzlPosY1 –
[Explanation] Not used.
[Default] 0 (This setting is ignored.)
Z_NzlPosZ1 –
[Explanation] Not used.
[Default] 0 (This setting is ignored.)
Z_NzlPosZH X
[Explanation] Sets the maximum height when picking up nozzle.
[Default] Proper data measurement result.
X_RemoverPos –
[Explanation] Not used.
[Default] 0
Y_RemoverPos –
[Explanation] Not used.
[Default] 0
Z_RemoverPos –
[Explanation] Not used.
[Default] 0
_NzlPosOffsetX1 –
[Explanation] Not used.
[Default] 0
_NzlPosOffsetY1 –
[Explanation] Not used.
[Default] 0
_NzlPosOffsetX2 –
[Explanation] Not used.
[Default] 0
_NzlPosOffsetY2 –
[Explanation] Not used.
[Default] 0
_NzlPosOffsetX3 –
[Explanation] Not used.
[Default] 0
_NzlPosOffsetY3 –
[Explanation] Not used.
[Default] 0
Part 6 Chapter 1 Proper Data Measurement
Edition 2.0 6-1-34 XP-142E System Reference